CVE-2021-25310 (GCVE-0-2021-25310)
Vulnerability from cvelistv5 – Published: 2021-02-02 14:01 – Updated: 2024-08-03 20:03 Unsupported When Assigned
VLAI?
Summary
The administration web interface on Belkin Linksys WRT160NL 1.0.04.002_US_20130619 devices allows remote authenticated attackers to execute system commands with root privileges via shell metacharacters in the ui_language POST parameter to the apply.cgi form endpoint. This occurs in do_upgrade_post in mini_httpd. NOTE: This vulnerability only affects products that are no longer supported by the maintaine
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:belkin:linksys_wrt_160nl:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "linksys_wrt_160nl",
"vendor": "belkin",
"versions": [
{
"status": "affected",
"version": "-"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-25310",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-22T15:20:58.646131Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-150",
"description": "CWE-150 Improper Neutralization of Escape, Meta, or Control Sequences",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:12:36.299Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:03:04.118Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://research.nccgroup.com/?research=Technical%20advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://research.nccgroup.com/2021/01/28/technical-advisory-linksys-wrt160nl-authenticated-command-injection-cve-2021-25310/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The administration web interface on Belkin Linksys WRT160NL 1.0.04.002_US_20130619 devices allows remote authenticated attackers to execute system commands with root privileges via shell metacharacters in the ui_language POST parameter to the apply.cgi form endpoint. This occurs in do_upgrade_post in mini_httpd. NOTE: This vulnerability only affects products that are no longer supported by the maintaine"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-02T14:01:08",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://research.nccgroup.com/?research=Technical%20advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://research.nccgroup.com/2021/01/28/technical-advisory-linksys-wrt160nl-authenticated-command-injection-cve-2021-25310/"
}
],
"tags": [
"unsupported-when-assigned"
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-25310",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** UNSUPPORTED WHEN ASSIGNED ** The administration web interface on Belkin Linksys WRT160NL 1.0.04.002_US_20130619 devices allows remote authenticated attackers to execute system commands with root privileges via shell metacharacters in the ui_language POST parameter to the apply.cgi form endpoint. This occurs in do_upgrade_post in mini_httpd. NOTE: This vulnerability only affects products that are no longer supported by the maintainer"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://research.nccgroup.com/?research=Technical%20advisories",
"refsource": "MISC",
"url": "https://research.nccgroup.com/?research=Technical%20advisories"
},
{
"name": "https://research.nccgroup.com/2021/01/28/technical-advisory-linksys-wrt160nl-authenticated-command-injection-cve-2021-25310/",
"refsource": "MISC",
"url": "https://research.nccgroup.com/2021/01/28/technical-advisory-linksys-wrt160nl-authenticated-command-injection-cve-2021-25310/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-25310",
"datePublished": "2021-02-02T14:01:08",
"dateReserved": "2021-01-18T00:00:00",
"dateUpdated": "2024-08-03T20:03:04.118Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:belkin:linksys_wrt160nl_firmware:1.0.04.002_us_20130619:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7BBC15B2-F457-4092-8FDD-C54132DD7B5B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:belkin:linksys_wrt160nl:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9976136E-FFCF-4DA1-8A6F-8496EDEDEF71\"}]}]}]",
"cveTags": "[{\"sourceIdentifier\": \"cve@mitre.org\", \"tags\": [\"unsupported-when-assigned\"]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"The administration web interface on Belkin Linksys WRT160NL 1.0.04.002_US_20130619 devices allows remote authenticated attackers to execute system commands with root privileges via shell metacharacters in the ui_language POST parameter to the apply.cgi form endpoint. This occurs in do_upgrade_post in mini_httpd. NOTE: This vulnerability only affects products that are no longer supported by the maintaine\"}, {\"lang\": \"es\", \"value\": \"** NO COMPATIBLE CUANDO SE ASIGN\\u00d3 ** La interfaz web de administraci\\u00f3n en los dispositivos Belkin Linksys WRT160NL versi\\u00f3n 1.0.04.002_US_20130619, permite a atacantes autenticados remotos ejecutar comandos del sistema con privilegios de root por medio de metacaracteres de shell en el par\\u00e1metro POST ui_language en el endpoint del formulario apply.cgi.\u0026#xa0;Esto ocurre en do_upgrade_post en mini_httpd.\u0026#xa0;NOTA: Esta vulnerabilidad solo afecta a los productos que ya no son compatibles por el mantenedor\"}]",
"id": "CVE-2021-25310",
"lastModified": "2024-11-21T05:54:43.200",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C\", \"baseScore\": 9.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.0, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2021-02-02T15:15:16.840",
"references": "[{\"url\": \"https://research.nccgroup.com/2021/01/28/technical-advisory-linksys-wrt160nl-authenticated-command-injection-cve-2021-25310/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://research.nccgroup.com/?research=Technical%20advisories\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://research.nccgroup.com/2021/01/28/technical-advisory-linksys-wrt160nl-authenticated-command-injection-cve-2021-25310/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://research.nccgroup.com/?research=Technical%20advisories\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}, {\"source\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-150\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-25310\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2021-02-02T15:15:16.840\",\"lastModified\":\"2024-11-21T05:54:43.200\",\"vulnStatus\":\"Modified\",\"cveTags\":[{\"sourceIdentifier\":\"cve@mitre.org\",\"tags\":[\"unsupported-when-assigned\"]}],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The administration web interface on Belkin Linksys WRT160NL 1.0.04.002_US_20130619 devices allows remote authenticated attackers to execute system commands with root privileges via shell metacharacters in the ui_language POST parameter to the apply.cgi form endpoint. This occurs in do_upgrade_post in mini_httpd. NOTE: This vulnerability only affects products that are no longer supported by the maintaine\"},{\"lang\":\"es\",\"value\":\"** NO COMPATIBLE CUANDO SE ASIGN\u00d3 ** La interfaz web de administraci\u00f3n en los dispositivos Belkin Linksys WRT160NL versi\u00f3n 1.0.04.002_US_20130619, permite a atacantes autenticados remotos ejecutar comandos del sistema con privilegios de root por medio de metacaracteres de shell en el par\u00e1metro POST ui_language en el endpoint del formulario apply.cgi.\u0026#xa0;Esto ocurre en do_upgrade_post en mini_httpd.\u0026#xa0;NOTA: Esta vulnerabilidad solo afecta a los productos que ya no son compatibles por el mantenedor\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-150\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:belkin:linksys_wrt160nl_firmware:1.0.04.002_us_20130619:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7BBC15B2-F457-4092-8FDD-C54132DD7B5B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:belkin:linksys_wrt160nl:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9976136E-FFCF-4DA1-8A6F-8496EDEDEF71\"}]}]}],\"references\":[{\"url\":\"https://research.nccgroup.com/2021/01/28/technical-advisory-linksys-wrt160nl-authenticated-command-injection-cve-2021-25310/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://research.nccgroup.com/?research=Technical%20advisories\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://research.nccgroup.com/2021/01/28/technical-advisory-linksys-wrt160nl-authenticated-command-injection-cve-2021-25310/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://research.nccgroup.com/?research=Technical%20advisories\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://research.nccgroup.com/?research=Technical%20advisories\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"https://research.nccgroup.com/2021/01/28/technical-advisory-linksys-wrt160nl-authenticated-command-injection-cve-2021-25310/\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T20:03:04.118Z\"}}, {\"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2021-25310\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-04-22T15:20:58.646131Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:h:belkin:linksys_wrt_160nl:-:*:*:*:*:*:*:*\"], \"vendor\": \"belkin\", \"product\": \"linksys_wrt_160nl\", \"versions\": [{\"status\": \"affected\", \"version\": \"-\"}], \"defaultStatus\": \"unknown\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-150\", \"description\": \"CWE-150 Improper Neutralization of Escape, Meta, or Control Sequences\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-04-22T15:17:07.633Z\"}, \"title\": \"CISA ADP Vulnrichment\"}], \"cna\": {\"tags\": [\"unsupported-when-assigned\"], \"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://research.nccgroup.com/?research=Technical%20advisories\", \"tags\": [\"x_refsource_MISC\"]}, {\"url\": \"https://research.nccgroup.com/2021/01/28/technical-advisory-linksys-wrt160nl-authenticated-command-injection-cve-2021-25310/\", \"tags\": [\"x_refsource_MISC\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"The administration web interface on Belkin Linksys WRT160NL 1.0.04.002_US_20130619 devices allows remote authenticated attackers to execute system commands with root privileges via shell metacharacters in the ui_language POST parameter to the apply.cgi form endpoint. This occurs in do_upgrade_post in mini_httpd. NOTE: This vulnerability only affects products that are no longer supported by the maintaine\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2021-02-02T14:01:08\"}, \"x_legacyV4Record\": {\"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"n/a\"}]}, \"product_name\": \"n/a\"}]}, \"vendor_name\": \"n/a\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://research.nccgroup.com/?research=Technical%20advisories\", \"name\": \"https://research.nccgroup.com/?research=Technical%20advisories\", \"refsource\": \"MISC\"}, {\"url\": \"https://research.nccgroup.com/2021/01/28/technical-advisory-linksys-wrt160nl-authenticated-command-injection-cve-2021-25310/\", \"name\": \"https://research.nccgroup.com/2021/01/28/technical-advisory-linksys-wrt160nl-authenticated-command-injection-cve-2021-25310/\", \"refsource\": \"MISC\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"** UNSUPPORTED WHEN ASSIGNED ** The administration web interface on Belkin Linksys WRT160NL 1.0.04.002_US_20130619 devices allows remote authenticated attackers to execute system commands with root privileges via shell metacharacters in the ui_language POST parameter to the apply.cgi form endpoint. This occurs in do_upgrade_post in mini_httpd. NOTE: This vulnerability only affects products that are no longer supported by the maintainer\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"n/a\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2021-25310\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"cve@mitre.org\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2021-25310\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-03T20:03:04.118Z\", \"dateReserved\": \"2021-01-18T00:00:00\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2021-02-02T14:01:08\", \"assignerShortName\": \"mitre\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…