CVE-2021-27442
Vulnerability from cvelistv5
Published
2022-05-16 17:13
Modified
2024-09-17 01:46
Severity ?
EPSS score ?
Summary
Weintek EasyWeb cMT Cross-site Scripting
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://dl.weintek.com/public/Document/TEC/TEC21001E_cMT_EasyWeb_V1_Security_Issues.pdf | Mitigation, Vendor Advisory | |
ics-cert@hq.dhs.gov | https://www.cisa.gov/uscert/ics/advisories/icsa-21-082-01 | Third Party Advisory, US Government Resource |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:17.243Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-082-01" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://dl.weintek.com/public/Document/TEC/TEC21001E_cMT_EasyWeb_V1_Security_Issues.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "cMT-SVR-1xx/2xx", "vendor": "Weintek", "versions": [ { "lessThan": "20210305", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "cMT-G01/G02", "vendor": "Weintek", "versions": [ { "lessThan": "20210209", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "cMT-G03/G04", "vendor": "Weintek", "versions": [ { "lessThan": "20210222", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "cMT3071/cMT3072/cMT3090/cMT3103/cMT3151", "vendor": "Weintek", "versions": [ { "lessThan": "20210218", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "cMT-HDM", "vendor": "Weintek", "versions": [ { "lessThan": "20210204", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "cMT-FHD", "vendor": "Weintek", "versions": [ { "lessThan": "20210208", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "cMT-CTRL01", "vendor": "Weintek", "versions": [ { "lessThan": "20210302", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Marcin Dudek from CERT.PL reported these vulnerabilities to CISA." } ], "datePublic": "2021-03-23T00:00:00", "descriptions": [ { "lang": "en", "value": "The Weintek cMT product line is vulnerable to a cross-site scripting vulnerability, which could allow an unauthenticated remote attacker to inject malicious JavaScript code." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 9.4, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Cross-site Scripting", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-16T17:13:17", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-082-01" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://dl.weintek.com/public/Document/TEC/TEC21001E_cMT_EasyWeb_V1_Security_Issues.pdf" } ], "solutions": [ { "lang": "en", "value": "Weintek has released OS upgrades for the affected products. Refer to Weintek\u2019s Technical Notice regarding these vulnerabilities.\nhttps://www.weintek.com/globalw/Download/Download.aspx\nhttps://dl.weintek.com/public/Document/TEC/TEC21001E_cMT_EasyWeb_V1_Security_Issues.pdf" } ], "source": { "discovery": "EXTERNAL" }, "title": "Weintek EasyWeb cMT Cross-site Scripting", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2021-03-23T17:00:00.000Z", "ID": "CVE-2021-27442", "STATE": "PUBLIC", "TITLE": "Weintek EasyWeb cMT Cross-site Scripting" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "cMT-SVR-1xx/2xx", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "20210305" } ] } }, { "product_name": "cMT-G01/G02", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "20210209" } ] } }, { "product_name": "cMT-G03/G04", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "20210222" } ] } }, { "product_name": "cMT3071/cMT3072/cMT3090/cMT3103/cMT3151", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "20210218" } ] } }, { "product_name": "cMT-HDM", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "20210204" } ] } }, { "product_name": "cMT-FHD", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "20210208" } ] } }, { "product_name": "cMT-CTRL01", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "20210302" } ] } } ] }, "vendor_name": "Weintek" } ] } }, "credit": [ { "lang": "eng", "value": "Marcin Dudek from CERT.PL reported these vulnerabilities to CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The Weintek cMT product line is vulnerable to a cross-site scripting vulnerability, which could allow an unauthenticated remote attacker to inject malicious JavaScript code." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 9.4, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-79: Cross-site Scripting" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-082-01", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-082-01" }, { "name": "https://dl.weintek.com/public/Document/TEC/TEC21001E_cMT_EasyWeb_V1_Security_Issues.pdf", "refsource": "CONFIRM", "url": "https://dl.weintek.com/public/Document/TEC/TEC21001E_cMT_EasyWeb_V1_Security_Issues.pdf" } ] }, "solution": [ { "lang": "en", "value": "Weintek has released OS upgrades for the affected products. Refer to Weintek\u2019s Technical Notice regarding these vulnerabilities.\nhttps://www.weintek.com/globalw/Download/Download.aspx\nhttps://dl.weintek.com/public/Document/TEC/TEC21001E_cMT_EasyWeb_V1_Security_Issues.pdf" } ], "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-27442", "datePublished": "2022-05-16T17:13:17.743462Z", "dateReserved": "2021-02-19T00:00:00", "dateUpdated": "2024-09-17T01:46:30.177Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-27442\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2022-05-16T18:15:08.043\",\"lastModified\":\"2022-05-25T16:22:08.153\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Weintek cMT product line is vulnerable to a cross-site scripting vulnerability, which could allow an unauthenticated remote attacker to inject malicious JavaScript code.\"},{\"lang\":\"es\",\"value\":\"La l\u00ednea de productos Weintek cMT es vulnerable a una vulnerabilidad de tipo Cross-site scripting, que podr\u00eda permitir a un atacante remoto no autenticado inyectar c\u00f3digo JavaScript malicioso\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7},{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\",\"baseScore\":9.4,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.5}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.3},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt-svr-100_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210305\",\"matchCriteriaId\":\"2BD9FCBF-CD84-4863-A4E4-613BD228D2CA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt-svr-100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"408166F7-5030-4FDA-94CF-4DD2237A1EA7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt-svr-102_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210305\",\"matchCriteriaId\":\"E6D1FD50-6AD9-4F6F-84A2-1646542350CC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt-svr-102:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5EE3CBE0-6B56-4405-91E2-15DB0C6E7967\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt-svr-200_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210305\",\"matchCriteriaId\":\"176DF351-ECB2-44F8-9009-48B76D9EB867\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt-svr-200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"673841CB-C2D6-486C-8C5D-0180173196D9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt-svr-202_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210305\",\"matchCriteriaId\":\"A7AA6AD2-B144-437E-B185-4BD47703A54B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt-svr-202:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AB57299A-5F53-44A5-B1D3-2E554180562B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt-g01_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210209\",\"matchCriteriaId\":\"5985D77C-E9BF-4E1B-8128-A0737281B8FA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt-g01:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E0ADA01D-E62C-4D53-B70D-BFB750CA2B52\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt-g02_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210209\",\"matchCriteriaId\":\"0BF566CC-966E-48E9-B6C9-F6CA52FFEAA1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt-g02:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1FB93C5F-4C71-4337-B72F-FE9B6E5CF83C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt-g03_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210222\",\"matchCriteriaId\":\"F59201D7-3D0B-446F-90B9-FD19C9DB04C0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt-g03:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"61343FB6-5943-4FE7-9E3C-56F184622B7B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt-g04_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210222\",\"matchCriteriaId\":\"F264AD39-4A3F-4273-A951-6DCB6768E82F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt-g04:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B2BCB236-F9AC-4729-BCAF-F005250C0F2E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt3071_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210218\",\"matchCriteriaId\":\"37D305D8-34F6-4BEF-99D4-CF4A18EFA9D3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt3071:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A4DE53C8-09D5-4D5E-97EE-A89E1478CD65\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt3072_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210218\",\"matchCriteriaId\":\"8A20906F-F91F-486A-9340-8D22C93C19AE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt3072:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E3F83A8D-1489-48AA-911B-5BA561A57896\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt3090_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210218\",\"matchCriteriaId\":\"A84ABF9C-EC9B-4CBF-967F-5F38DCD32A16\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt3090:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"79C1F694-08A2-46E7-95C2-8DFA3D64423B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt3103_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210218\",\"matchCriteriaId\":\"B70E20F8-83E0-45C9-B02F-D1957AD47C6A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt3103:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F607716E-7B7B-4620-819C-F44341B8C37F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt3151_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210218\",\"matchCriteriaId\":\"F5065F83-0BD0-44B1-9E64-8689F0F3B4D0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt3151:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9FF5326B-5E33-4C11-9AC6-A90357078FCA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt-hdm_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210204\",\"matchCriteriaId\":\"0A793B51-28F7-4A17-BD4C-74C2FCA053FC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt-hdm:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E08E3518-A03F-486D-B67A-013F67026D78\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt-fhd_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210208\",\"matchCriteriaId\":\"81DBEE28-6A04-43E0-9C5E-592162179896\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt-fhd:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A132B170-A1FC-4D38-9965-0FF47B944FD5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:weintek:cmt-ctrl01_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"20210302\",\"matchCriteriaId\":\"38F4698D-B9D6-42E4-9867-9BDCC2F2F2A8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:weintek:cmt-ctrl01:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1C9CB899-1EE6-4599-861D-9BBA4856E5CE\"}]}]}],\"references\":[{\"url\":\"https://dl.weintek.com/public/Document/TEC/TEC21001E_cMT_EasyWeb_V1_Security_Issues.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-21-082-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.