CVE-2021-32025 (GCVE-0-2021-32025)

Vulnerability from cvelistv5 – Published: 2022-03-09 20:37 – Updated: 2025-08-22 15:36
VLAI?
Summary
An elevation of privilege vulnerability in the QNX Neutrino Kernel of affected versions of QNX Software Development Platform version(s) 6.4.0 to 7.0, QNX Momentics all 6.3.x versions, QNX OS for Safety versions 1.0.0 to 1.0.2, QNX OS for Safety versions 2.0.0 to 2.0.1, QNX for Medical versions 1.0.0 to 1.1.1, and QNX OS for Medical version 2.0.0 could allow an attacker to potentially access data, modify behavior, or permanently crash the system.
CWE
  • Elevation of privilege
  • CWE-368 - Context Switching Race Condition
Assigner
References
Impacted products
Vendor Product Version
BlackBerry QNX Software Development Platform (SDP), QNX OS for Medical (QOSM), and QNX OS for Safety (QOS) Affected: QNX SDP 6.4.0 to 7.0
Affected: QNX Momentics all 6.3.x versions
Affected: QNX OS for Safety versions 1.0.0 to 1.0.2 safety products compliant with IEC 61508 and/or ISO 26262
Affected: QNX OS for Safety versions 2.0.0 to 2.0.1 safety products compliant with IEC 61508 and/or ISO 26262
Affected: QNX OS for Medical versions 1.0.0 to 1.1.1 safety products compliant with IEC 62304
Affected: QNX OS for Medical versions 2.0.0 safety product compliant with IEC 62304
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:17:28.155Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000090868"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "QNX\u202fSoftware Development Platform (SDP), QNX OS for Medical (QOSM), and QNX OS for Safety (QOS)",
          "vendor": "BlackBerry",
          "versions": [
            {
              "status": "affected",
              "version": "QNX SDP 6.4.0 to 7.0"
            },
            {
              "status": "affected",
              "version": "QNX Momentics all 6.3.x versions"
            },
            {
              "status": "affected",
              "version": "QNX OS for Safety versions 1.0.0 to 1.0.2 safety products compliant with IEC 61508 and/or ISO 26262"
            },
            {
              "status": "affected",
              "version": "QNX OS for Safety versions 2.0.0 to 2.0.1 safety products compliant with IEC 61508 and/or ISO 26262"
            },
            {
              "status": "affected",
              "version": "QNX OS for Medical versions 1.0.0 to 1.1.1 safety products compliant with IEC 62304"
            },
            {
              "status": "affected",
              "version": "QNX OS for Medical versions 2.0.0 safety product compliant with IEC 62304"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn elevation of privilege vulnerability in the QNX Neutrino Kernel of affected versions of QNX Software Development Platform version(s) 6.4.0 to 7.0, QNX Momentics all 6.3.x versions, QNX OS for Safety versions 1.0.0 to 1.0.2, QNX OS for Safety versions 2.0.0 to 2.0.1, QNX for Medical versions 1.0.0 to 1.1.1, and QNX OS for Medical version 2.0.0 could allow an attacker to potentially access data, modify behavior, or permanently crash the system.\u003c/p\u003e"
            }
          ],
          "value": "An elevation of privilege vulnerability in the QNX Neutrino Kernel of affected versions of QNX Software Development Platform version(s) 6.4.0 to 7.0, QNX Momentics all 6.3.x versions, QNX OS for Safety versions 1.0.0 to 1.0.2, QNX OS for Safety versions 2.0.0 to 2.0.1, QNX for Medical versions 1.0.0 to 1.1.1, and QNX OS for Medical version 2.0.0 could allow an attacker to potentially access data, modify behavior, or permanently crash the system."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-549",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-549 Local Execution of Code"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Elevation of privilege",
              "lang": "en"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-368",
              "description": "CWE-368 Context Switching Race Condition",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-22T15:36:00.384Z",
        "orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
        "shortName": "blackberry"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000090868"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@blackberry.com",
          "ID": "CVE-2021-32025",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "QNX\u202fSoftware Development Platform (SDP), QNX OS for Medical (QOSM), and QNX OS for Safety (QOS)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "QNX SDP 6.4.0 to 7.0"
                          },
                          {
                            "version_value": "QNX Momentics all 6.3.x versions"
                          },
                          {
                            "version_value": "QNX OS for Safety versions 1.0.0 to 1.0.2 safety products compliant with IEC 61508 and/or ISO 26262"
                          },
                          {
                            "version_value": "QNX OS for Safety versions 2.0.0 to 2.0.1 safety products compliant with IEC 61508 and/or ISO 26262"
                          },
                          {
                            "version_value": "QNX OS for Medical versions 1.0.0 to 1.1.1 safety products compliant with IEC 62304"
                          },
                          {
                            "version_value": "QNX OS for Medical versions 2.0.0 safety product compliant with IEC 62304"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An elevation of privilege vulnerability in the QNX Neutrino Kernel of affected versions of QNX Software Development Platform version(s) 6.4.0 to 7.0, QNX Momentics all 6.3.x versions, QNX OS for Safety versions 1.0.0 to 1.0.2, QNX OS for Safety versions 2.0.0 to 2.0.1, QNX for Medical versions 1.0.0 to 1.1.1, and QNX OS for Medical version 2.0.0 could allow an attacker to potentially access data, modify behavior, or permanently crash the system."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Elevation of privilege"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000090868",
              "refsource": "MISC",
              "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000090868"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
    "assignerShortName": "blackberry",
    "cveId": "CVE-2021-32025",
    "datePublished": "2022-03-09T20:37:56",
    "dateReserved": "2021-05-03T00:00:00",
    "dateUpdated": "2025-08-22T15:36:00.384Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:blackberry:qnx_momentics:6.3.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3AC84B1C-6981-4C3D-952E-4F724EFDEF1D\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:blackberry:qnx_momentics:6.3.2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"44452791-7402-44DD-ADB1-2A36310EB365\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:blackberry:qnx_software_development_platform:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"6.4.0\", \"versionEndIncluding\": \"7.0\", \"matchCriteriaId\": \"B51E6454-60B6-4913-BCF4-F23C3F1D8722\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:blackberry:qnx_os_for_medical:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"1.0\", \"versionEndExcluding\": \"1.1.2\", \"matchCriteriaId\": \"DBC6F8A4-9440-4D3E-8FE8-B5F0A2BB34A2\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:blackberry:qnx_os_for_medical:2.0.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B6348483-2214-4B7A-A61A-13813A3BC5B9\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:blackberry:qnx_os_for_safety:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"1.0.0\", \"versionEndExcluding\": \"1.0.3\", \"matchCriteriaId\": \"0913E9B4-F15A-4A86-B933-5D237FAA5451\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:blackberry:qnx_os_for_safety:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2.0.0\", \"versionEndExcluding\": \"2.0.2\", \"matchCriteriaId\": \"8DC0E7C7-275A-4214-8232-725CF8B70EE9\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"An elevation of privilege vulnerability in the QNX Neutrino Kernel of affected versions of QNX Software Development Platform version(s) 6.4.0 to 7.0, QNX Momentics all 6.3.x versions, QNX OS for Safety versions 1.0.0 to 1.0.2, QNX OS for Safety versions 2.0.0 to 2.0.1, QNX for Medical versions 1.0.0 to 1.1.1, and QNX OS for Medical version 2.0.0 could allow an attacker to potentially access data, modify behavior, or permanently crash the system.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad de elevaci\\u00f3n de privilegios en el QNX Neutrino Kernel de las versiones afectadas de QNX Software Development Platform versi\\u00f3n(es) 6.4.0 a 7.0, QNX Momentics todas las versiones 6.3.x, QNX OS for Safety versiones 1.0.0 a 1.0. 2, QNX OS for Safety versiones 2.0.0 a 2.0.1, QNX for Medical versiones 1.0.0 a 1.1.1, y QNX OS for Medical versi\\u00f3n 2.0.0, podr\\u00eda permitir a un atacante acceder potencialmente a los datos, modificar el comportamiento o bloquear permanentemente el sistema\"}]",
      "id": "CVE-2021-32025",
      "lastModified": "2024-11-21T06:06:44.353",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 7.2, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 3.9, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2022-03-10T17:42:14.083",
      "references": "[{\"url\": \"http://support.blackberry.com/kb/articleDetail?articleNumber=000090868\", \"source\": \"secure@blackberry.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"http://support.blackberry.com/kb/articleDetail?articleNumber=000090868\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "secure@blackberry.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-32025\",\"sourceIdentifier\":\"secure@blackberry.com\",\"published\":\"2022-03-10T17:42:14.083\",\"lastModified\":\"2025-08-22T16:15:34.010\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An elevation of privilege vulnerability in the QNX Neutrino Kernel of affected versions of QNX Software Development Platform version(s) 6.4.0 to 7.0, QNX Momentics all 6.3.x versions, QNX OS for Safety versions 1.0.0 to 1.0.2, QNX OS for Safety versions 2.0.0 to 2.0.1, QNX for Medical versions 1.0.0 to 1.1.1, and QNX OS for Medical version 2.0.0 could allow an attacker to potentially access data, modify behavior, or permanently crash the system.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de elevaci\u00f3n de privilegios en el QNX Neutrino Kernel de las versiones afectadas de QNX Software Development Platform versi\u00f3n(es) 6.4.0 a 7.0, QNX Momentics todas las versiones 6.3.x, QNX OS for Safety versiones 1.0.0 a 1.0. 2, QNX OS for Safety versiones 2.0.0 a 2.0.1, QNX for Medical versiones 1.0.0 a 1.1.1, y QNX OS for Medical versi\u00f3n 2.0.0, podr\u00eda permitir a un atacante acceder potencialmente a los datos, modificar el comportamiento o bloquear permanentemente el sistema\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"secure@blackberry.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.4,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"secure@blackberry.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-368\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:blackberry:qnx_momentics:6.3.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3AC84B1C-6981-4C3D-952E-4F724EFDEF1D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:blackberry:qnx_momentics:6.3.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"44452791-7402-44DD-ADB1-2A36310EB365\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:blackberry:qnx_software_development_platform:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.4.0\",\"versionEndIncluding\":\"7.0\",\"matchCriteriaId\":\"B51E6454-60B6-4913-BCF4-F23C3F1D8722\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:blackberry:qnx_os_for_medical:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.0\",\"versionEndExcluding\":\"1.1.2\",\"matchCriteriaId\":\"DBC6F8A4-9440-4D3E-8FE8-B5F0A2BB34A2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:blackberry:qnx_os_for_medical:2.0.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B6348483-2214-4B7A-A61A-13813A3BC5B9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:blackberry:qnx_os_for_safety:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.0.0\",\"versionEndExcluding\":\"1.0.3\",\"matchCriteriaId\":\"0913E9B4-F15A-4A86-B933-5D237FAA5451\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:blackberry:qnx_os_for_safety:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.0.0\",\"versionEndExcluding\":\"2.0.2\",\"matchCriteriaId\":\"8DC0E7C7-275A-4214-8232-725CF8B70EE9\"}]}]}],\"references\":[{\"url\":\"http://support.blackberry.com/kb/articleDetail?articleNumber=000090868\",\"source\":\"secure@blackberry.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://support.blackberry.com/kb/articleDetail?articleNumber=000090868\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…