CVE-2021-33842 (GCVE-0-2021-33842)

Vulnerability from cvelistv5 – Published: 2021-06-09 11:39 – Updated: 2024-09-16 20:01
VLAI?
Summary
Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located.
CWE
  • CWE-565 - Reliance on Cookies without Validation and Integrity Checking
Assigner
References
Impacted products
Vendor Product Version
Circutor SGE-PLC1000 Affected: 0.9.2b
Create a notification for this product.
Credits
Industrial Cybersecurity team of S21sec, special mention to Aarón Flecha Menéndez.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:58:23.180Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-improper-authentication"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SGE-PLC1000",
          "vendor": "Circutor",
          "versions": [
            {
              "status": "affected",
              "version": "0.9.2b"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Industrial Cybersecurity team of S21sec, special mention to Aar\u00f3n Flecha Men\u00e9ndez."
        }
      ],
      "datePublic": "2021-06-07T22:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located."
            }
          ],
          "value": "Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-565",
              "description": "CWE-565 Reliance on Cookies without Validation and Integrity Checking",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-23T13:47:01.158Z",
        "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "shortName": "INCIBE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-improper-authentication"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "This issue can be solved through a firmware upgrade that has already been released by the vendor."
            }
          ],
          "value": "This issue can be solved through a firmware upgrade that has already been released by the vendor."
        }
      ],
      "source": {
        "advisory": "INCIBE-2021-0228",
        "discovery": "EXTERNAL"
      },
      "title": "Circutor SGE-PLC1000 improper authentication",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve-coordination@incibe.es",
          "DATE_PUBLIC": "2021-06-08T08:00:00.000Z",
          "ID": "CVE-2021-33842",
          "STATE": "PUBLIC",
          "TITLE": "Circutor SGE-PLC1000 improper authentication"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SGE-PLC1000",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "0.9.2b",
                            "version_value": "0.9.2b"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Circutor"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Industrial Cybersecurity team of S21sec, special mention to Aar\u00f3n Flecha Men\u00e9ndez."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287: Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.incibe-cert.es/en/early-warning/ics-advisories/circutor-sge-plc1000-improper-authentication",
              "refsource": "CONFIRM",
              "url": "https://www.incibe-cert.es/en/early-warning/ics-advisories/circutor-sge-plc1000-improper-authentication"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "This issue can be solved through a firmware upgrade that has already been released by the vendor."
          }
        ],
        "source": {
          "advisory": "INCIBE-2021-0228",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
    "assignerShortName": "INCIBE",
    "cveId": "CVE-2021-33842",
    "datePublished": "2021-06-09T11:39:52.302361Z",
    "dateReserved": "2021-06-04T00:00:00",
    "dateUpdated": "2024-09-16T20:01:18.942Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:circutor:sge-plc1000_firmware:0.9.2b:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5D6B02E0-DE36-45F5-AD3D-908E30548661\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FFF41215-1018-42DD-9A7E-BBC2E5B4522D\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad de Autenticaci\\u00f3n Inapropiada en el par\\u00e1metro cookies de Circutor SGE-PLC1000 versi\\u00f3n del firmware 0.9.2b, permite a un atacante llevar a cabo operaciones como un usuario autenticado.\u0026#xa0;Para explotar esta vulnerabilidad, el atacante debe estar dentro de la red donde se encuentra el dispositivo afectado\"}]",
      "id": "CVE-2021-33842",
      "lastModified": "2024-11-21T06:09:40.603",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"cve-coordination@incibe.es\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:A/AC:L/Au:S/C:C/I:C/A:C\", \"baseScore\": 7.7, \"accessVector\": \"ADJACENT_NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 5.1, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2021-06-09T12:15:07.957",
      "references": "[{\"url\": \"https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-improper-authentication\", \"source\": \"cve-coordination@incibe.es\"}, {\"url\": \"https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-improper-authentication\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
      "sourceIdentifier": "cve-coordination@incibe.es",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"cve-coordination@incibe.es\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-565\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-565\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-33842\",\"sourceIdentifier\":\"cve-coordination@incibe.es\",\"published\":\"2021-06-09T12:15:07.957\",\"lastModified\":\"2024-11-21T06:09:40.603\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de Autenticaci\u00f3n Inapropiada en el par\u00e1metro cookies de Circutor SGE-PLC1000 versi\u00f3n del firmware 0.9.2b, permite a un atacante llevar a cabo operaciones como un usuario autenticado.\u0026#xa0;Para explotar esta vulnerabilidad, el atacante debe estar dentro de la red donde se encuentra el dispositivo afectado\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve-coordination@incibe.es\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:A/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":7.7,\"accessVector\":\"ADJACENT_NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":5.1,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cve-coordination@incibe.es\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-565\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-565\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:circutor:sge-plc1000_firmware:0.9.2b:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5D6B02E0-DE36-45F5-AD3D-908E30548661\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FFF41215-1018-42DD-9A7E-BBC2E5B4522D\"}]}]}],\"references\":[{\"url\":\"https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-improper-authentication\",\"source\":\"cve-coordination@incibe.es\"},{\"url\":\"https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-improper-authentication\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…