CVE-2021-42025
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-04 03:22
Severity
Summary
A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions < V8.18.13), Mendix Applications using Mendix 9 (All versions < V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control write access for certain client actions. This could allow authenticated attackers to manipulate the content of System.FileDocument objects in some cases, regardless whether they have write access to it.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:22:25.924Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.13"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions \u003c V8.18.13), Mendix Applications using Mendix 9 (All versions \u003c V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control write access for certain client actions. This could allow authenticated attackers to manipulate the content of System.FileDocument objects in some cases, regardless whether they have write access to it."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863: Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-09T11:32:16",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-42025",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.18.13"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.6.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions \u003c V8.18.13), Mendix Applications using Mendix 9 (All versions \u003c V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control write access for certain client actions. This could allow authenticated attackers to manipulate the content of System.FileDocument objects in some cases, regardless whether they have write access to it."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-863: Incorrect Authorization"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-42025",
    "datePublished": "2021-11-09T11:32:16",
    "dateReserved": "2021-10-06T00:00:00",
    "dateUpdated": "2024-08-04T03:22:25.924Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-42025\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-11-09T12:15:10.587\",\"lastModified\":\"2021-11-12T21:54:49.157\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions \u003c V8.18.13), Mendix Applications using Mendix 9 (All versions \u003c V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control write access for certain client actions. This could allow authenticated attackers to manipulate the content of System.FileDocument objects in some cases, regardless whether they have write access to it.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en las aplicaciones de Mendix usadas en Mendix versi\u00f3n 8 (Todas las versiones anteriores a V8.18.13), aplicaciones de Mendix usadas en Mendix versi\u00f3n 9 (Todas las versiones anteriores a V9.6.2). Las aplicaciones construidas con las versiones afectadas de Mendix Studio Pro no controlan apropiadamente el acceso de escritura para determinadas acciones del cliente. Esto podr\u00eda permitir a atacantes autenticados manipular el contenido de los objetos System.FileDocument en algunos casos, independientemente de que tengan acceso de escritura\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:N/I:C/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-863\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.0.0\",\"versionEndExcluding\":\"8.18.13\",\"matchCriteriaId\":\"77846974-E401-4C9A-8546-6C0F58F84010\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.0.0\",\"versionEndExcluding\":\"9.6.2\",\"matchCriteriaId\":\"CD6DC146-2C4D-4CA2-BAB6-C74D3669A439\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}