CVE-2022-22512 (GCVE-0-2022-22512)

Vulnerability from cvelistv5 – Published: 2023-03-23 05:32 – Updated: 2025-02-25 19:24
VLAI?
Title
VARTA: Multiple devices prone to hard-coded credentials
Summary
Hard-coded credentials in Web-UI of multiple VARTA Storage products in multiple versions allows an unauthorized attacker to gain administrative access to the Web-UI via network.
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
Impacted products
Vendor Product Version
VARTA Storage Element backup Affected: 0 , < F21000400 (semver)
Create a notification for this product.
Credits
Andreas Dolp CERT@VDE
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.324Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2022-061/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-22512",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-25T19:24:11.167146Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-25T19:24:27.774Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Element backup",
          "vendor": "VARTA Storage",
          "versions": [
            {
              "lessThan": "F21000400",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Element S1",
          "vendor": "VARTA Storage",
          "versions": [
            {
              "lessThan": "2e.3.8.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Element S2",
          "vendor": "VARTA Storage",
          "versions": [
            {
              "lessThan": "2e.3.8.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Element S2",
          "vendor": "VARTA Storage",
          "versions": [
            {
              "lessThan": "2e.3.8.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Element S3",
          "vendor": "VARTA Storage",
          "versions": [
            {
              "lessThan": "2e.3.8.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Element S3",
          "vendor": "VARTA Storage",
          "versions": [
            {
              "lessThan": "2e.4.4.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Element S4",
          "vendor": "VARTA Storage",
          "versions": [
            {
              "lessThan": "D21010400",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "One L/XL",
          "vendor": "VARTA Storage",
          "versions": [
            {
              "lessThan": "2e.3.8.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Pulse (not pulse neo)",
          "vendor": "VARTA Storage",
          "versions": [
            {
              "lessThan": "C21010800",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andreas Dolp"
        },
        {
          "lang": "en",
          "type": "coordinator",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "CERT@VDE"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Hard-coded credentials in Web-UI of multiple VARTA Storage products in multiple versions allows an unauthorized attacker to gain administrative access to the Web-UI via network."
            }
          ],
          "value": "Hard-coded credentials in Web-UI of multiple VARTA Storage products in multiple versions allows an unauthorized attacker to gain administrative access to the Web-UI via network."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-150",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-150 Collect Data from Common Resource Locations"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-23T06:06:45.925Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2022-061/"
        }
      ],
      "source": {
        "advisory": "VDE-2022-061",
        "defect": [
          "CERT@VDE#64092"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "VARTA: Multiple devices prone to hard-coded credentials",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-22512",
    "datePublished": "2023-03-23T05:32:16.285Z",
    "dateReserved": "2022-01-03T22:35:36.934Z",
    "dateUpdated": "2025-02-25T19:24:27.774Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:varta:element_backup_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"f21000400\", \"matchCriteriaId\": \"2B8FFA7A-1C91-4C5B-A1E0-F057A1B83B90\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:varta:element_backup:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"18A32228-1E64-4F09-B8EA-F122F7F8EFBA\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:varta:element_s1_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2e.3.8.0\", \"matchCriteriaId\": \"1D85D801-4958-4949-B8C1-8CF486B463E8\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:varta:element_s1:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"19031686-7D24-408D-9144-1286C2C288B7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:varta:element_s2_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2e.3.8.0\", \"matchCriteriaId\": \"F1AB1110-6B20-46CD-81EE-C893D02FED70\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:varta:element_s2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E9BCEA27-93B4-4D04-8E2A-4A0CC4EA725E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:varta:element_s3_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2e.3.8.0\", \"matchCriteriaId\": \"3E3B1FD3-CFA7-4585-B58F-DE3C67C952B5\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:varta:element_s3_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2e.4.0.0\", \"versionEndExcluding\": \"2e.4.4.0\", \"matchCriteriaId\": \"290140CE-3093-42D1-8060-A1DF88695CE9\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:varta:element_s3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"67ACACF9-DBAF-4C23-AD99-2966BC9DE24A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:varta:element_s4_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"d21010400\", \"matchCriteriaId\": \"29167A22-1E33-4DD8-BD6D-9046F6D11394\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:varta:element_s4:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1A2E6700-E663-4F91-8F2C-2D543A5B074D\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:varta:one_l_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2e.3.8.0\", \"matchCriteriaId\": \"99BB655C-9E6E-4373-9B87-1A012DFAFACB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:varta:one_l:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6FE9CF95-00C5-4913-9BFE-B57F1014FE7C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:varta:one_xl_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2e.3.8.0\", \"matchCriteriaId\": \"79C4C11C-02D8-4580-A2F6-23A7FD861CB7\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:varta:one_xl:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0CFDDC29-1017-4404-B7F1-2B935A3C44CD\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:varta:pulse_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"c21010800\", \"matchCriteriaId\": \"025EF312-0B07-4553-8AF7-EEDD80A65FC1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:varta:pulse:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F4E8517B-A421-44E3-850E-DD8D7C9A63FE\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Hard-coded credentials in Web-UI of multiple VARTA Storage products in multiple versions allows an unauthorized attacker to gain administrative access to the Web-UI via network.\"}]",
      "id": "CVE-2022-22512",
      "lastModified": "2024-11-21T06:46:55.760",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"info@cert.vde.com\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}]}",
      "published": "2023-03-23T06:15:12.367",
      "references": "[{\"url\": \"https://cert.vde.com/en/advisories/VDE-2022-061/\", \"source\": \"info@cert.vde.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://cert.vde.com/en/advisories/VDE-2022-061/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"info@cert.vde.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-798\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-22512\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2023-03-23T06:15:12.367\",\"lastModified\":\"2024-11-21T06:46:55.760\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Hard-coded credentials in Web-UI of multiple VARTA Storage products in multiple versions allows an unauthorized attacker to gain administrative access to the Web-UI via network.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:varta:element_backup_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"f21000400\",\"matchCriteriaId\":\"2B8FFA7A-1C91-4C5B-A1E0-F057A1B83B90\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:varta:element_backup:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18A32228-1E64-4F09-B8EA-F122F7F8EFBA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:varta:element_s1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2e.3.8.0\",\"matchCriteriaId\":\"1D85D801-4958-4949-B8C1-8CF486B463E8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:varta:element_s1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"19031686-7D24-408D-9144-1286C2C288B7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:varta:element_s2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2e.3.8.0\",\"matchCriteriaId\":\"F1AB1110-6B20-46CD-81EE-C893D02FED70\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:varta:element_s2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E9BCEA27-93B4-4D04-8E2A-4A0CC4EA725E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:varta:element_s3_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2e.3.8.0\",\"matchCriteriaId\":\"3E3B1FD3-CFA7-4585-B58F-DE3C67C952B5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:varta:element_s3_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2e.4.0.0\",\"versionEndExcluding\":\"2e.4.4.0\",\"matchCriteriaId\":\"290140CE-3093-42D1-8060-A1DF88695CE9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:varta:element_s3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"67ACACF9-DBAF-4C23-AD99-2966BC9DE24A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:varta:element_s4_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"d21010400\",\"matchCriteriaId\":\"29167A22-1E33-4DD8-BD6D-9046F6D11394\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:varta:element_s4:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1A2E6700-E663-4F91-8F2C-2D543A5B074D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:varta:one_l_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2e.3.8.0\",\"matchCriteriaId\":\"99BB655C-9E6E-4373-9B87-1A012DFAFACB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:varta:one_l:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6FE9CF95-00C5-4913-9BFE-B57F1014FE7C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:varta:one_xl_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2e.3.8.0\",\"matchCriteriaId\":\"79C4C11C-02D8-4580-A2F6-23A7FD861CB7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:varta:one_xl:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0CFDDC29-1017-4404-B7F1-2B935A3C44CD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:varta:pulse_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"c21010800\",\"matchCriteriaId\":\"025EF312-0B07-4553-8AF7-EEDD80A65FC1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:varta:pulse:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F4E8517B-A421-44E3-850E-DD8D7C9A63FE\"}]}]}],\"references\":[{\"url\":\"https://cert.vde.com/en/advisories/VDE-2022-061/\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://cert.vde.com/en/advisories/VDE-2022-061/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert.vde.com/en/advisories/VDE-2022-061/\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T03:14:55.324Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-22512\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-25T19:24:11.167146Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-25T19:24:23.077Z\"}}], \"cna\": {\"title\": \"VARTA: Multiple devices prone to hard-coded credentials\", \"source\": {\"defect\": [\"CERT@VDE#64092\"], \"advisory\": \"VDE-2022-061\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Andreas Dolp\"}, {\"lang\": \"en\", \"type\": \"coordinator\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"CERT@VDE\"}], \"impacts\": [{\"capecId\": \"CAPEC-150\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-150 Collect Data from Common Resource Locations\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"VARTA Storage\", \"product\": \"Element backup\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"F21000400\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"VARTA Storage\", \"product\": \"Element S1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2e.3.8.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"VARTA Storage\", \"product\": \"Element S2\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2e.3.8.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"VARTA Storage\", \"product\": \"Element S2\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2e.3.8.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"VARTA Storage\", \"product\": \"Element S3\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2e.3.8.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"VARTA Storage\", \"product\": \"Element S3\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2e.4.4.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"VARTA Storage\", \"product\": \"Element S4\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"D21010400\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"VARTA Storage\", \"product\": \"One L/XL\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2e.3.8.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"VARTA Storage\", \"product\": \"Pulse (not pulse neo)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"C21010800\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://cert.vde.com/en/advisories/VDE-2022-061/\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Hard-coded credentials in Web-UI of multiple VARTA Storage products in multiple versions allows an unauthorized attacker to gain administrative access to the Web-UI via network.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Hard-coded credentials in Web-UI of multiple VARTA Storage products in multiple versions allows an unauthorized attacker to gain administrative access to the Web-UI via network.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-798\", \"description\": \"CWE-798 Use of Hard-coded Credentials\"}]}], \"providerMetadata\": {\"orgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"shortName\": \"CERTVDE\", \"dateUpdated\": \"2023-05-23T06:06:45.925Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2022-22512\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-25T19:24:27.774Z\", \"dateReserved\": \"2022-01-03T22:35:36.934Z\", \"assignerOrgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"datePublished\": \"2023-03-23T05:32:16.285Z\", \"assignerShortName\": \"CERTVDE\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…