CVE-2022-24309
Vulnerability from cvelistv5
Published
2022-03-08 11:31
Modified
2024-10-08 08:39
Summary
A vulnerability has been identified in Mendix Runtime V7 (All versions < V7.23.29), Mendix Runtime V8 (All versions < V8.18.16), Mendix Runtime V9 (All versions < V9.13 only with Runtime Custom Setting *DataStorage.UseNewQueryHandler* set to False). If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:07:02.516Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148641.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.23.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.18.16",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V7 (All versions \u003c V7.23.29), Mendix Runtime V8 (All versions \u003c V8.18.16), Mendix Runtime V9 (All versions \u003c V9.13 only with Runtime Custom Setting *DataStorage.UseNewQueryHandler* set to False). If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:39:51.939Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148641.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-24309",
    "datePublished": "2022-03-08T11:31:29",
    "dateReserved": "2022-02-02T00:00:00",
    "dateUpdated": "2024-10-08T08:39:51.939Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-24309\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-03-08T12:15:11.580\",\"lastModified\":\"2024-10-08T09:15:07.060\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Mendix Runtime V7 (All versions \u003c V7.23.29), Mendix Runtime V8 (All versions \u003c V8.18.16), Mendix Runtime V9 (All versions \u003c V9.13 only with Runtime Custom Setting *DataStorage.UseNewQueryHandler* set to False). If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en las aplicaciones de Mendix que utilizan Mendix 7 (todas las versiones anteriores a V7.23.29), las aplicaciones de Mendix que utilizan Mendix 8 (todas las versiones anteriores a V8.18.16) y las aplicaciones de Mendix que utilizan Mendix 9 (todas las implementaciones con la configuraci\u00f3n personalizada del tiempo de ejecuci\u00f3n *DataStorage.UseNewQueryHandler* establecida en False). Si una entidad tiene una asociaci\u00f3n legible por el usuario, en algunos casos, Mendix Runtime puede no aplicar las comprobaciones de las restricciones XPath que analizan dichas asociaciones, dentro de las aplicaciones que se ejecutan en las versiones afectadas. Un usuario malintencionado podr\u00eda utilizar esto para volcar y manipular datos sensibles\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.2},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.6,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:P/I:P/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.9},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":6.8,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.23.29\",\"matchCriteriaId\":\"D15C35A3-18EA-4BC7-B093-4849F454A5C7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.0.0\",\"versionEndExcluding\":\"8.18.16\",\"matchCriteriaId\":\"8475161B-1B30-4555-85B4-D9C4E309EB92\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.0.0\",\"matchCriteriaId\":\"4EFCC29F-3789-4508-97F1-9E3833663B5E\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-148641.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-148641.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Mitigation\",\"Release Notes\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.