On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:36:06.970Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://files.iclinks.com/datasheets/Scadaflex%20II/Scadaflex%20SC-1%20\u0026%20SC-2_A1_compressed.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://packetstormsecurity.com/files/166103/ICL-ScadaFlex-II-SCADA-Controllers-SC-1-SC-2-1.03.07-Remote-File-Modification.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-26T04:19:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://files.iclinks.com/datasheets/Scadaflex%20II/Scadaflex%20SC-1%20\u0026%20SC-2_A1_compressed.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://packetstormsecurity.com/files/166103/ICL-ScadaFlex-II-SCADA-Controllers-SC-1-SC-2-1.03.07-Remote-File-Modification.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25359",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://files.iclinks.com/datasheets/Scadaflex%20II/Scadaflex%20SC-1%20\u0026%20SC-2_A1_compressed.pdf",
              "refsource": "MISC",
              "url": "http://files.iclinks.com/datasheets/Scadaflex%20II/Scadaflex%20SC-1%20\u0026%20SC-2_A1_compressed.pdf"
            },
            {
              "name": "https://packetstormsecurity.com/files/166103/ICL-ScadaFlex-II-SCADA-Controllers-SC-1-SC-2-1.03.07-Remote-File-Modification.html",
              "refsource": "MISC",
              "url": "https://packetstormsecurity.com/files/166103/ICL-ScadaFlex-II-SCADA-Controllers-SC-1-SC-2-1.03.07-Remote-File-Modification.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25359",
    "datePublished": "2022-02-26T04:19:01",
    "dateReserved": "2022-02-18T00:00:00",
    "dateUpdated": "2024-08-03T04:36:06.970Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-25359\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-02-26T05:15:08.407\",\"lastModified\":\"2023-08-08T14:21:49.707\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files.\"},{\"lang\":\"es\",\"value\":\"En los dispositivos ICL ScadaFlex II SCADA Controller SC-1 y SC-2 versi\u00f3n 1.03.07, los atacantes remotos no autenticados pueden sobrescribir, eliminar o crear archivos.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":6.4},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iclinks:scadaflex_ii_firmware:1.01.01:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0F8A94A2-3131-4CF8-9746-B97784321E15\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iclinks:scadaflex_ii_firmware:1.01.14:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"86855C02-1001-4A29-AEDA-E50236B513EB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iclinks:scadaflex_ii_firmware:1.02.01:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B5CB3BCE-2561-4AF8-96AF-E4E89D05319E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iclinks:scadaflex_ii_firmware:1.02.15:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7EC6EAC1-B005-43B8-8BA9-CFDD4C7F81D3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iclinks:scadaflex_ii_firmware:1.02.20:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"49009933-DB7E-4107-A6BD-DC3265CA27E8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iclinks:scadaflex_ii_firmware:1.03.07:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3AD3B7CE-3184-40EF-A956-C597FD23E6CB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iclinks:weblib:1.13:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FFBE1106-D84D-48DD-98E9-6EBF09299BB4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iclinks:weblib:1.14:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2C2F9B4F-58D5-49B3-9F5D-54BF01F31F1F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iclinks:weblib:1.16:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E74CECC3-5B48-4B2C-B817-E9B1F5D37EEC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iclinks:weblib:1.22:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8C76FC41-5696-4AEA-AEC5-247120527D2C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iclinks:weblib:1.24:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7BEE2E4C-2B6D-48C7-BC7F-62C5DDF470DC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:iclinks:scadaflex_ii:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C4862199-5DA8-47C5-9238-F9BE3E3455C3\"}]}]}],\"references\":[{\"url\":\"http://files.iclinks.com/datasheets/Scadaflex%20II/Scadaflex%20SC-1%20\u0026%20SC-2_A1_compressed.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Product\",\"Vendor Advisory\"]},{\"url\":\"https://packetstormsecurity.com/files/166103/ICL-ScadaFlex-II-SCADA-Controllers-SC-1-SC-2-1.03.07-Remote-File-Modification.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\",\"VDB Entry\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.