CVE-2022-28703 (GCVE-0-2022-28703)

Vulnerability from cvelistv5 – Published: 2022-12-19 10:00 – Updated: 2025-04-15 18:39
VLAI?
Summary
A stored cross-site scripting vulnerability exists in the HdConfigActions.aspx altertextlanguages functionality of Lansweeper lansweeper 10.1.1.0. A specially-crafted HTTP request can lead to arbitrary Javascript code injection. An attacker can send an HTTP request to trigger this vulnerability.
CWE
  • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Assigner
Impacted products
Vendor Product Version
Lansweeper lansweeper Affected: 10.1.1.0
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:03:52.070Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1532"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-28703",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-15T18:17:21.794878Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T18:39:02.214Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "lansweeper",
          "vendor": "Lansweeper",
          "versions": [
            {
              "status": "affected",
              "version": "10.1.1.0"
            }
          ]
        }
      ],
      "datePublic": "2022-12-01T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A stored cross-site scripting vulnerability exists in the HdConfigActions.aspx altertextlanguages functionality of Lansweeper lansweeper 10.1.1.0. A specially-crafted HTTP request can lead to arbitrary Javascript code injection. An attacker can send an HTTP request to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-15T00:00:00.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1532"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2022-28703",
    "datePublished": "2022-12-19T10:00:14.221Z",
    "dateReserved": "2022-06-09T00:00:00.000Z",
    "dateUpdated": "2025-04-15T18:39:02.214Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:lansweeper:lansweeper:10.1.1.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2B678EA8-701A-4508-BC31-AE93AEE6F1EE\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A stored cross-site scripting vulnerability exists in the HdConfigActions.aspx altertextlanguages functionality of Lansweeper lansweeper 10.1.1.0. A specially-crafted HTTP request can lead to arbitrary Javascript code injection. An attacker can send an HTTP request to trigger this vulnerability.\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad de Cross-Site Scripting (XSS) Almacenado en la funcionalidad altertextlanguages HdConfigActions.aspx de Lansweeper lansweeper 10.1.1.0. Una solicitud HTTP especialmente manipulada puede provocar una inyecci\\u00f3n de c\\u00f3digo Javascript arbitrario. Un atacante puede enviar una solicitud HTTP para desencadenar esta vulnerabilidad.\"}]",
      "id": "CVE-2022-28703",
      "lastModified": "2024-11-21T06:57:46.163",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 5.4, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 2.7}], \"cvssMetricV30\": [{\"source\": \"talos-cna@cisco.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\", \"baseScore\": 9.1, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 6.0}]}",
      "published": "2022-12-15T10:15:11.420",
      "references": "[{\"url\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1532\", \"source\": \"talos-cna@cisco.com\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1532\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}]",
      "sourceIdentifier": "talos-cna@cisco.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"talos-cna@cisco.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-80\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-28703\",\"sourceIdentifier\":\"talos-cna@cisco.com\",\"published\":\"2022-12-15T10:15:11.420\",\"lastModified\":\"2024-11-21T06:57:46.163\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A stored cross-site scripting vulnerability exists in the HdConfigActions.aspx altertextlanguages functionality of Lansweeper lansweeper 10.1.1.0. A specially-crafted HTTP request can lead to arbitrary Javascript code injection. An attacker can send an HTTP request to trigger this vulnerability.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de Cross-Site Scripting (XSS) Almacenado en la funcionalidad altertextlanguages HdConfigActions.aspx de Lansweeper lansweeper 10.1.1.0. Una solicitud HTTP especialmente manipulada puede provocar una inyecci\u00f3n de c\u00f3digo Javascript arbitrario. Un atacante puede enviar una solicitud HTTP para desencadenar esta vulnerabilidad.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7}],\"cvssMetricV30\":[{\"source\":\"talos-cna@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.3,\"impactScore\":6.0}]},\"weaknesses\":[{\"source\":\"talos-cna@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-80\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:lansweeper:lansweeper:10.1.1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2B678EA8-701A-4508-BC31-AE93AEE6F1EE\"}]}]}],\"references\":[{\"url\":\"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1532\",\"source\":\"talos-cna@cisco.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1532\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1532\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T06:03:52.070Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-28703\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-15T18:17:21.794878Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-15T18:17:23.274Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_0\": {\"scope\": \"CHANGED\", \"version\": \"3.0\", \"baseScore\": 9.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"Lansweeper\", \"product\": \"lansweeper\", \"versions\": [{\"status\": \"affected\", \"version\": \"10.1.1.0\"}]}], \"datePublic\": \"2022-12-01T00:00:00.000Z\", \"references\": [{\"url\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1532\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A stored cross-site scripting vulnerability exists in the HdConfigActions.aspx altertextlanguages functionality of Lansweeper lansweeper 10.1.1.0. A specially-crafted HTTP request can lead to arbitrary Javascript code injection. An attacker can send an HTTP request to trigger this vulnerability.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-80\", \"description\": \"CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)\"}]}], \"providerMetadata\": {\"orgId\": \"b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b\", \"shortName\": \"talos\", \"dateUpdated\": \"2022-12-15T00:00:00.000Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2022-28703\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-15T18:39:02.214Z\", \"dateReserved\": \"2022-06-09T00:00:00.000Z\", \"assignerOrgId\": \"b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b\", \"datePublished\": \"2022-12-19T10:00:14.221Z\", \"assignerShortName\": \"talos\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…