Siemens | SINEMA Remote Connect Server |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2022-32254", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-09T13:30:15.766322Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-09T13:30:34.167Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-03T07:39:50.261Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-484086.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SINEMA Remote Connect Server", "vendor": "Siemens", "versions": [ { "lessThan": "V3.1", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker." } ], "metrics": [ { "cvssV3_1": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-532", "description": "CWE-532: Insertion of Sensitive Information into Log File", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:04:11.937Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-484086.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-32254", "datePublished": "2022-06-14T09:22:06", "dateReserved": "2022-06-02T00:00:00", "dateUpdated": "2024-08-03T07:39:50.261Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-32254\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-06-14T10:15:20.867\",\"lastModified\":\"2024-07-09T12:15:07.040\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a V3.1). Una petici\u00f3n HTTP POST personalizada podr\u00eda forzar a la aplicaci\u00f3n a escribir el estado de un determinado usuario en un archivo de registro, exponiendo informaci\u00f3n confidencial del usuario que podr\u00eda proporcionar una valiosa orientaci\u00f3n a un atacante\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-532\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-532\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.1\",\"matchCriteriaId\":\"98CC9C9A-FE14-4D50-A8EC-C309229356C8\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-484086.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
icsa-22-167-17
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "notifying CISA of these vulnerabilities" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to escalate privileges, disclose information, or allow code execution.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/icsSeveral recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov/icsin the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-22-167-17 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-167-17.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-167-17 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-167-17" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SINEMA Remote Connect Server", "tracking": { "current_release_date": "2022-06-16T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-167-17", "initial_release_date": "2022-06-16T00:00:00.000000Z", "revision_history": [ { "date": "2022-06-16T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-22-167-17 Siemens SINEMA Remote Connect Server" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 3.1", "product": { "name": "Siemens SINEMA Remote Connect Server: All versions prior to v3.1", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Siemens SINEMA Remote Connect Server" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-22925", "cwe": { "id": "CWE-706", "name": "Use of Incorrectly-Resolved Name or Reference" }, "notes": [ { "category": "summary", "text": "libcurl keeps previously used connections in a connection pool for subsequent transfers to reuse. Errors in the logic could lead to libcurl reusing wrong connections.CVE-2021-22925 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22925" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-45960", "cwe": { "id": "CWE-908", "name": "Use of Uninitialized Resource" }, "notes": [ { "category": "summary", "text": "curl supports the -t command line option, known as CURLOPT_TELNETOPTIONS in libcurl. Due to a flaw in the option parser, libcurl could pass on uninitialized data from a stack-based buffer to the server, revealing sensitive internal information to the server.CVE-2021-45960 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-45960" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-46143", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "In Expat, also called libexpat, versions prior to 2.4.3 a left shift by 29 (or more) places in the storeAtts function in xmlparse.c can lead to realloc misbehavior.CVE-2021-46143 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-46143" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-22822", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "In doProlog in xmlparse.c in Expat, also called libexpat, versions prior to 2.4.3, an integer overflow exists for m_groupSize.CVE-2022-22822 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-22822" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-22823", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "addBinding in xmlparse.c in Expat, also called libexpat, has an integer overflow in versions prior to 2.4.3.CVE-2022-22823 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-22823" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-22824", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "build_model in xmlparse.c in Expat, also called libexpat, has an integer overflow in versions prior to 2.4.3.CVE-2022-22824 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-22824" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-22825", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "defineAttribute in xmlparse.c in Expat, also called libexpat, has an integer overflow in versions prior to 2.4.3.CVE-2022-22825 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-22825" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-22826", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "lookup in xmlparse.c in Expat, also called libexpat, has an integer overflow in versions prior to 2.4.3.CVE-2022-22826 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-22826" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-22827", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "nextScaffoldPart in xmlparse.c in Expat, also called libexpat, has an integer overflow in versions prior to 2.4.3.CVE-2022-22827 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-22827" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-23852", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "storeAtts in xmlparse.c in Expat, also called libexpat, has an integer overflow in versions prior to 2.4.3.CVE-2022-23852 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23852" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-23990", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "Expat, also called libexpat, versions prior to 2.4.4 have a signed integer overflow in XML_GetBuffer for configurations with a nonzero XML_CONTEXT_BYTES.CVE-2022-23990 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23990" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-25235", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "Expat, also called libexpat, versions prior to 2.4.4 have an integer overflow in the doProlog function.CVE-2022-25235 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25235" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-25236", "cwe": { "id": "CWE-116", "name": "Improper Encoding or Escaping of Output" }, "notes": [ { "category": "summary", "text": "xmltok_impl.c in Expat, also called libexpat, versions prior to 2.4.5 lack a certain validation of encoding, such as checks for whether a UTF-8 character is valid in a certain context.CVE-2022-25236 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25236" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-25313", "cwe": { "id": "CWE-668", "name": "Exposure of Resource to Wrong Sphere" }, "notes": [ { "category": "summary", "text": "xmlparse.c in Expat, also called libexpat, versions prior to 2.4.5 allows attackers to insert namespace-separator characters into namespace URIs.CVE-2022-25313 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25313" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-25314", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "In Expat, also called libexpat, versions prior to 2.4.5, an attacker can trigger stack exhaustion in build_model via a large nesting depth in the DTD element.CVE-2022-25314 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25314" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-25315", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "In Expat, also called libexpat versions prior to 2.4.5, there is an integer overflow in copyString.CVE-2022-25315 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25315" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-27221", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "In Expat, also called libexpat, versions prior to 2.4.5, there is an integer overflow in storeRawNames.CVE-2022-27221 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-27221" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-29034", "cwe": { "id": "CWE-331", "name": "Insufficient Entropy" }, "notes": [ { "category": "summary", "text": "An attacker employing a machine-in-the-middle attack could obtain plaintext secret values by observing length differences during a series of guesses, in which a string in an HTTP request URL matches an unknown string in an HTTP response body (i.e., BREACH attack).CVE-2022-29034 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29034" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 6.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-32251", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "An error message pop up window in the web interface of the affected application does not prevent injection of JavaScript code, allowing reflected cross-site scripting attacks.CVE-2022-32251 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32251" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-32252", "cwe": { "id": "CWE-306", "name": "Missing Authentication for Critical Function" }, "notes": [ { "category": "summary", "text": "There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain privileges of an administrative user.CVE-2022-32252 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32252" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-32253", "cwe": { "id": "CWE-345", "name": "Insufficient Verification of Data Authenticity" }, "notes": [ { "category": "summary", "text": "The application does not perform the integrity check of the update packages. Without validation, an admin user could be tricked to install a malicious package, granting root privileges to an attacker.CVE-2022-32253 has been assigned to this vulnerability. A CVSS v3 base score of 4.9 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32253" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-32254", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Due to improper input validation, the OpenSSL certificate \u0027s password could be printed to a file reachable by an attacker.CVE-2022-32254 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32254" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-32255", "cwe": { "id": "CWE-532", "name": "Insertion of Sensitive Information into Log File" }, "notes": [ { "category": "summary", "text": "A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information.CVE-2022-32255 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32255" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-32256", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The affected application \u0027s web service lacks proper access control for some endpoints. This vulnerability could lead to unauthorized access to information.CVE-2022-32256 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32256" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-32258", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The affected application \u0027s web service lacks proper access control for some endpoints. This could lead to low privileged users \u0027 access to privileged information.CVE-2022-32258 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32258" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-32259", "cwe": { "id": "CWE-448", "name": "Obsolete Feature in UI" }, "notes": [ { "category": "summary", "text": "The affected application allows the import of device configurations via a specific endpoint, which could allow information disclosure.CVE-2022-32259 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32259" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-32260", "cwe": { "id": "CWE-1244", "name": "Internal Asset Exposed to Unsafe Debug Access Level or State" }, "notes": [ { "category": "summary", "text": "The system images for installation or update of the affected application contain unit test scripts with sensitive information. An attacker could gain information about testing architecture and tamper with test configuration.CVE-2022-32260 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32260" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-32261", "cwe": { "id": "CWE-286", "name": "Incorrect User Management" }, "notes": [ { "category": "summary", "text": "The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass.CVE-2022-32261 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32261" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-32262", "cwe": { "id": "CWE-223", "name": "Omission of Security-relevant Information" }, "notes": [ { "category": "summary", "text": "The affected application contains a misconfiguration in the APT update. This vulnerability could allow an attacker to add insecure packages to the application.CVE-2022-32262 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32262" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends updating the products to the latest version of their software:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "The update of SINEMA Remote Connect Server to v3.1 also contains additional fixes for vulnerabilities documented in the following Siemens Security Advisories:", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html" }, { "category": "vendor_fix", "details": "For further inquiries on security vulnerabilities in Siemens products and solutions, contact Siemens.", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.siemens.com/global/en/products/services/cert.html" }, { "category": "vendor_fix", "details": "As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for industrial security and following recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.siemens.com/industrialsecurity" }, { "category": "vendor_fix", "details": "For more information see Siemens Security Advisory SSA-484086", "product_ids": [ "CSAFPID-0001" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
ghsa-xgg7-m84q-m968
Vulnerability from github
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker.
{ "affected": [], "aliases": [ "CVE-2022-32254" ], "database_specific": { "cwe_ids": [ "CWE-532" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-06-14T10:15:00Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker.", "id": "GHSA-xgg7-m84q-m968", "modified": "2024-07-09T12:30:55Z", "published": "2022-06-15T00:00:29Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-32254" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-484086.html" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "type": "CVSS_V3" } ] }
gsd-2022-32254
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2022-32254", "description": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker.", "id": "GSD-2022-32254" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-32254" ], "details": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker.", "id": "GSD-2022-32254", "modified": "2023-12-13T01:19:12.406886Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-32254", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SINEMA Remote Connect Server", "version": { "version_data": [ { "version_value": "All versions \u003c V3.1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-532: Insertion of Sensitive Information into Log File" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.1", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-32254" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-532" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf", "refsource": "MISC", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2022-06-23T14:11Z", "publishedDate": "2022-06-14T10:15Z" } } }
var-202206-0845
Vulnerability from variot
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker. SINEMA Remote Connect is a remote network management platform for easy management of tunnel connections (VPN) between headquarters, service technicians and installed machines or plants. Attackers can use this vulnerability to obtain sensitive information of users
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202206-0845", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sinema remote connect server", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.1" } ], "sources": [ { "db": "NVD", "id": "CVE-2022-32254" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.1", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-32254" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens notified CISA of these vulnerabilities.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202206-1249" } ], "trust": 0.6 }, "cve": "CVE-2022-32254", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-424193", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-32254", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202206-1249", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-424193", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-424193" }, { "db": "NVD", "id": "CVE-2022-32254" }, { "db": "CNNVD", "id": "CNNVD-202206-1249" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker. SINEMA Remote Connect is a remote network management platform for easy management of tunnel connections (VPN) between headquarters, service technicians and installed machines or plants. Attackers can use this vulnerability to obtain sensitive information of users", "sources": [ { "db": "NVD", "id": "CVE-2022-32254" }, { "db": "VULHUB", "id": "VHN-424193" }, { "db": "VULMON", "id": "CVE-2022-32254" } ], "trust": 1.08 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-32254", "trust": 1.8 }, { "db": "SIEMENS", "id": "SSA-484086", "trust": 1.8 }, { "db": "ICS CERT", "id": "ICSA-22-167-17", "trust": 0.7 }, { "db": "CNNVD", "id": "CNNVD-202206-1249", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2022-45226", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-424193", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2022-32254", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-424193" }, { "db": "VULMON", "id": "CVE-2022-32254" }, { "db": "NVD", "id": "CVE-2022-32254" }, { "db": "CNNVD", "id": "CNNVD-202206-1249" } ] }, "id": "VAR-202206-0845", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-424193" } ], "trust": 0.01 }, "last_update_date": "2023-12-18T10:52:34.454000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Siemens SINEMA Remote Connect Server Repair measures for log information disclosure vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=197241" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202206-1249" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-532", "trust": 1.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-424193" }, { "db": "NVD", "id": "CVE-2022-32254" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-167-17" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-32254/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-17" } ], "sources": [ { "db": "VULHUB", "id": "VHN-424193" }, { "db": "VULMON", "id": "CVE-2022-32254" }, { "db": "NVD", "id": "CVE-2022-32254" }, { "db": "CNNVD", "id": "CNNVD-202206-1249" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-424193" }, { "db": "VULMON", "id": "CVE-2022-32254" }, { "db": "NVD", "id": "CVE-2022-32254" }, { "db": "CNNVD", "id": "CNNVD-202206-1249" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-06-14T00:00:00", "db": "VULHUB", "id": "VHN-424193" }, { "date": "2022-06-14T00:00:00", "db": "VULMON", "id": "CVE-2022-32254" }, { "date": "2022-06-14T10:15:20.867000", "db": "NVD", "id": "CVE-2022-32254" }, { "date": "2022-06-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202206-1249" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-06-23T00:00:00", "db": "VULHUB", "id": "VHN-424193" }, { "date": "2022-06-14T00:00:00", "db": "VULMON", "id": "CVE-2022-32254" }, { "date": "2022-06-23T14:11:17.130000", "db": "NVD", "id": "CVE-2022-32254" }, { "date": "2022-06-30T00:00:00", "db": "CNNVD", "id": "CNNVD-202206-1249" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202206-1249" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SINEMA Remote Connect Server Log information disclosure vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202206-1249" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "log information leak", "sources": [ { "db": "CNNVD", "id": "CNNVD-202206-1249" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.