CVE-2022-3323 (GCVE-0-2022-3323)
Vulnerability from cvelistv5 – Published: 2022-09-27 13:51 – Updated: 2025-05-21 15:10
VLAI?
Summary
An SQL injection vulnerability in Advantech iView 5.7.04.6469. The specific flaw exists within the ConfigurationServlet endpoint, which listens on TCP port 8080 by default. An unauthenticated remote attacker can craft a special column_value parameter in the setConfiguration action to bypass checks in com.imc.iview.utils.CUtils.checkSQLInjection() to perform SQL injection. For example, the attacker can exploit the vulnerability to retrieve the iView admin password.
Severity ?
7.5 (High)
CWE
- SQL Injection
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Advantech iView |
Affected:
Advantech iView 5.7.04.6469
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:07:06.488Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2022-32"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-3323",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-21T15:09:58.643861Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-21T15:10:35.138Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Advantech iView",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Advantech iView 5.7.04.6469"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An SQL injection vulnerability in Advantech iView 5.7.04.6469. The specific flaw exists within the ConfigurationServlet endpoint, which listens on TCP port 8080 by default. An unauthenticated remote attacker can craft a special column_value parameter in the setConfiguration action to bypass checks in com.imc.iview.utils.CUtils.checkSQLInjection() to perform SQL injection. For example, the attacker can exploit the vulnerability to retrieve the iView admin password."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "SQL Injection",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-27T13:51:02.000Z",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2022-32"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2022-3323",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Advantech iView",
"version": {
"version_data": [
{
"version_value": "Advantech iView 5.7.04.6469"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An SQL injection vulnerability in Advantech iView 5.7.04.6469. The specific flaw exists within the ConfigurationServlet endpoint, which listens on TCP port 8080 by default. An unauthenticated remote attacker can craft a special column_value parameter in the setConfiguration action to bypass checks in com.imc.iview.utils.CUtils.checkSQLInjection() to perform SQL injection. For example, the attacker can exploit the vulnerability to retrieve the iView admin password."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "SQL Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2022-32",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2022-32"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2022-3323",
"datePublished": "2022-09-27T13:51:02.000Z",
"dateReserved": "2022-09-26T00:00:00.000Z",
"dateUpdated": "2025-05-21T15:10:35.138Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:advantech:iview:5.7.04.6469:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6E39B345-0A1D-4908-B715-8549878F73FF\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"An SQL injection vulnerability in Advantech iView 5.7.04.6469. The specific flaw exists within the ConfigurationServlet endpoint, which listens on TCP port 8080 by default. An unauthenticated remote attacker can craft a special column_value parameter in the setConfiguration action to bypass checks in com.imc.iview.utils.CUtils.checkSQLInjection() to perform SQL injection. For example, the attacker can exploit the vulnerability to retrieve the iView admin password.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad de inyecci\\u00f3n SQL en Advantech iView versi\\u00f3n 5.7.04.6469. La falla espec\\u00edfica se presenta dentro del endpoint ConfigurationServlet, que escucha en el puerto TCP 8080 por defecto. Un atacante remoto no autenticado puede dise\\u00f1ar un par\\u00e1metro column_value especial en la acci\\u00f3n setConfiguration para omitir las comprobaciones de com.imc.iview.utils.CUtils.checkSQLInjection() y llevar a cabo una inyecci\\u00f3n SQL. Por ejemplo, el atacante puede explotar la vulnerabilidad para recuperar la contrase\\u00f1a de administrador de iView\"}]",
"id": "CVE-2022-3323",
"lastModified": "2024-11-21T07:19:17.760",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
"published": "2022-09-27T23:15:15.867",
"references": "[{\"url\": \"https://www.tenable.com/security/research/tra-2022-32\", \"source\": \"vulnreport@tenable.com\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://www.tenable.com/security/research/tra-2022-32\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}]",
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-89\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-3323\",\"sourceIdentifier\":\"vulnreport@tenable.com\",\"published\":\"2022-09-27T23:15:15.867\",\"lastModified\":\"2025-05-21T15:15:59.000\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An SQL injection vulnerability in Advantech iView 5.7.04.6469. The specific flaw exists within the ConfigurationServlet endpoint, which listens on TCP port 8080 by default. An unauthenticated remote attacker can craft a special column_value parameter in the setConfiguration action to bypass checks in com.imc.iview.utils.CUtils.checkSQLInjection() to perform SQL injection. For example, the attacker can exploit the vulnerability to retrieve the iView admin password.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de inyecci\u00f3n SQL en Advantech iView versi\u00f3n 5.7.04.6469. La falla espec\u00edfica se presenta dentro del endpoint ConfigurationServlet, que escucha en el puerto TCP 8080 por defecto. Un atacante remoto no autenticado puede dise\u00f1ar un par\u00e1metro column_value especial en la acci\u00f3n setConfiguration para omitir las comprobaciones de com.imc.iview.utils.CUtils.checkSQLInjection() y llevar a cabo una inyecci\u00f3n SQL. Por ejemplo, el atacante puede explotar la vulnerabilidad para recuperar la contrase\u00f1a de administrador de iView\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:advantech:iview:5.7.04.6469:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6E39B345-0A1D-4908-B715-8549878F73FF\"}]}]}],\"references\":[{\"url\":\"https://www.tenable.com/security/research/tra-2022-32\",\"source\":\"vulnreport@tenable.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2022-32\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.tenable.com/security/research/tra-2022-32\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T01:07:06.488Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-3323\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-05-21T15:09:58.643861Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-89\", \"description\": \"CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-05-21T15:10:30.888Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"Advantech iView\", \"versions\": [{\"status\": \"affected\", \"version\": \"Advantech iView 5.7.04.6469\"}]}], \"references\": [{\"url\": \"https://www.tenable.com/security/research/tra-2022-32\", \"tags\": [\"x_refsource_MISC\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"An SQL injection vulnerability in Advantech iView 5.7.04.6469. The specific flaw exists within the ConfigurationServlet endpoint, which listens on TCP port 8080 by default. An unauthenticated remote attacker can craft a special column_value parameter in the setConfiguration action to bypass checks in com.imc.iview.utils.CUtils.checkSQLInjection() to perform SQL injection. For example, the attacker can exploit the vulnerability to retrieve the iView admin password.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"SQL Injection\"}]}], \"providerMetadata\": {\"orgId\": \"5ac1ecc2-367a-4d16-a0b2-35d495ddd0be\", \"shortName\": \"tenable\", \"dateUpdated\": \"2022-09-27T13:51:02.000Z\"}, \"x_legacyV4Record\": {\"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"Advantech iView 5.7.04.6469\"}]}, \"product_name\": \"Advantech iView\"}]}, \"vendor_name\": \"n/a\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://www.tenable.com/security/research/tra-2022-32\", \"name\": \"https://www.tenable.com/security/research/tra-2022-32\", \"refsource\": \"MISC\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"An SQL injection vulnerability in Advantech iView 5.7.04.6469. The specific flaw exists within the ConfigurationServlet endpoint, which listens on TCP port 8080 by default. An unauthenticated remote attacker can craft a special column_value parameter in the setConfiguration action to bypass checks in com.imc.iview.utils.CUtils.checkSQLInjection() to perform SQL injection. For example, the attacker can exploit the vulnerability to retrieve the iView admin password.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"SQL Injection\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2022-3323\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"vulnreport@tenable.com\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-3323\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-05-21T15:10:35.138Z\", \"dateReserved\": \"2022-09-26T00:00:00.000Z\", \"assignerOrgId\": \"5ac1ecc2-367a-4d16-a0b2-35d495ddd0be\", \"datePublished\": \"2022-09-27T13:51:02.000Z\", \"assignerShortName\": \"tenable\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…