CVE-2022-40860
Vulnerability from cvelistv5
Published
2022-09-23 13:47
Modified
2024-08-03 12:28
Severity ?
EPSS score ?
Summary
Tenda AC15 router V15.03.05.19 contains a stack overflow vulnerability in the function formSetQosBand->FUN_0007dd20 with request /goform/SetNetControlList
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/formSetQosBand.md | Exploit, Third Party Advisory |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:28:42.442Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/formSetQosBand.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC15 router V15.03.05.19 contains a stack overflow vulnerability in the function formSetQosBand-\u003eFUN_0007dd20 with request /goform/SetNetControlList" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-09-23T13:47:20", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/formSetQosBand.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-40860", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Tenda AC15 router V15.03.05.19 contains a stack overflow vulnerability in the function formSetQosBand-\u003eFUN_0007dd20 with request /goform/SetNetControlList" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/formSetQosBand.md", "refsource": "MISC", "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/formSetQosBand.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-40860", "datePublished": "2022-09-23T13:47:20", "dateReserved": "2022-09-19T00:00:00", "dateUpdated": "2024-08-03T12:28:42.442Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-40860\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-09-23T14:15:13.217\",\"lastModified\":\"2022-09-23T20:28:32.340\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Tenda AC15 router V15.03.05.19 contains a stack overflow vulnerability in the function formSetQosBand-\u003eFUN_0007dd20 with request /goform/SetNetControlList\"},{\"lang\":\"es\",\"value\":\"El router Tenda AC15 versi\u00f3n V15.03.05.19, contiene una vulnerabilidad de desbordamiento de pila en la funci\u00f3n formSetQosBand-)FUN_0007dd20 con la petici\u00f3n /goform/SetNetControlList\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tendacn:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7CF021B8-0BA1-42C9-A2A4-4B4BF18F8D4B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tendacn:ac15:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4EEDF33B-0D03-492A-BCD1-0E6B79F783EF\"}]}]}],\"references\":[{\"url\":\"https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/formSetQosBand.md\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.