CVE-2023-1488 (GCVE-0-2023-1488)

Vulnerability from cvelistv5 – Published: 2023-03-18 21:00 – Updated: 2024-08-02 05:49
VLAI?
Title
Lespeed WiseCleaner Wise System Monitor IoControlCode WiseHDInfo64.dll 0x9C40A0E0 denial of service
Summary
A vulnerability, which was classified as problematic, was found in Lespeed WiseCleaner Wise System Monitor 1.5.3.54. Affected is the function 0x9C40A0D8/0x9C40A0DC/0x9C40A0E0 in the library WiseHDInfo64.dll of the component IoControlCode Handler. The manipulation leads to denial of service. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. VDB-223374 is the identifier assigned to this vulnerability.
CWE
Assigner
Impacted products
Credits
Zeze7w (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T05:49:11.698Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.223374"
          },
          {
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.223374"
          },
          {
            "tags": [
              "related",
              "x_transferred"
            ],
            "url": "https://github.com/zeze-zeze/WindowsKernelVuln/tree/master/CVE-2023-1488"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://drive.google.com/file/d/1X4qH-BIww5jIdoYfg9WKvX5088cpMRHY/view"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "IoControlCode Handler"
          ],
          "product": "WiseCleaner Wise System Monitor",
          "vendor": "Lespeed",
          "versions": [
            {
              "status": "affected",
              "version": "1.5.3.54"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "analyst",
          "value": "Zeze7w (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as problematic, was found in Lespeed WiseCleaner Wise System Monitor 1.5.3.54. Affected is the function 0x9C40A0D8/0x9C40A0DC/0x9C40A0E0 in the library WiseHDInfo64.dll of the component IoControlCode Handler. The manipulation leads to denial of service. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. VDB-223374 is the identifier assigned to this vulnerability."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Lespeed WiseCleaner Wise System Monitor 1.5.3.54 gefunden. Sie wurde als problematisch eingestuft. Betroffen hiervon ist die Funktion 0x9C40A0D8/0x9C40A0DC/0x9C40A0E0 in der Bibliothek WiseHDInfo64.dll der Komponente IoControlCode Handler. Durch Manipulieren mit unbekannten Daten kann eine denial of service-Schwachstelle ausgenutzt werden. Der Angriff hat dabei lokal zu erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 1.7,
            "vectorString": "AV:L/AC:L/Au:S/C:N/I:N/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-404",
              "description": "CWE-404 Denial of Service",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-21T09:29:09.540Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.223374"
        },
        {
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.223374"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/zeze-zeze/WindowsKernelVuln/tree/master/CVE-2023-1488"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://drive.google.com/file/d/1X4qH-BIww5jIdoYfg9WKvX5088cpMRHY/view"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2023-03-18T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2023-03-18T00:00:00.000Z",
          "value": "CVE reserved"
        },
        {
          "lang": "en",
          "time": "2023-03-18T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2023-04-11T19:06:01.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Lespeed WiseCleaner Wise System Monitor IoControlCode WiseHDInfo64.dll 0x9C40A0E0 denial of service"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2023-1488",
    "datePublished": "2023-03-18T21:00:06.112Z",
    "dateReserved": "2023-03-18T20:02:54.286Z",
    "dateUpdated": "2024-08-02T05:49:11.698Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:wisecleaner:wise_system_monitor:1.5.3.54:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F6D0B338-3A8E-4206-BAB6-F29D4286E0B6\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability, which was classified as problematic, was found in Lespeed WiseCleaner Wise System Monitor 1.5.3.54. Affected is the function 0x9C40A0D8/0x9C40A0DC/0x9C40A0E0 in the library WiseHDInfo64.dll of the component IoControlCode Handler. The manipulation leads to denial of service. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. VDB-223374 is the identifier assigned to this vulnerability.\"}]",
      "id": "CVE-2023-1488",
      "lastModified": "2024-11-21T07:39:17.630",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L\", \"baseScore\": 3.3, \"baseSeverity\": \"LOW\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 1.4}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 5.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:S/C:N/I:N/A:P\", \"baseScore\": 1.7, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 3.1, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2023-03-18T21:15:11.550",
      "references": "[{\"url\": \"https://drive.google.com/file/d/1X4qH-BIww5jIdoYfg9WKvX5088cpMRHY/view\", \"source\": \"cna@vuldb.com\", \"tags\": [\"Exploit\"]}, {\"url\": \"https://github.com/zeze-zeze/WindowsKernelVuln/tree/master/CVE-2023-1488\", \"source\": \"cna@vuldb.com\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://vuldb.com/?ctiid.223374\", \"source\": \"cna@vuldb.com\", \"tags\": [\"Permissions Required\", \"Third Party Advisory\"]}, {\"url\": \"https://vuldb.com/?id.223374\", \"source\": \"cna@vuldb.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://drive.google.com/file/d/1X4qH-BIww5jIdoYfg9WKvX5088cpMRHY/view\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\"]}, {\"url\": \"https://github.com/zeze-zeze/WindowsKernelVuln/tree/master/CVE-2023-1488\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://vuldb.com/?ctiid.223374\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Permissions Required\", \"Third Party Advisory\"]}, {\"url\": \"https://vuldb.com/?id.223374\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
      "sourceIdentifier": "cna@vuldb.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"cna@vuldb.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-404\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-1488\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2023-03-18T21:15:11.550\",\"lastModified\":\"2024-11-21T07:39:17.630\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability, which was classified as problematic, was found in Lespeed WiseCleaner Wise System Monitor 1.5.3.54. Affected is the function 0x9C40A0D8/0x9C40A0DC/0x9C40A0E0 in the library WiseHDInfo64.dll of the component IoControlCode Handler. The manipulation leads to denial of service. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. VDB-223374 is the identifier assigned to this vulnerability.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":3.3,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":1.8,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:S/C:N/I:N/A:P\",\"baseScore\":1.7,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.1,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-404\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:wisecleaner:wise_system_monitor:1.5.3.54:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F6D0B338-3A8E-4206-BAB6-F29D4286E0B6\"}]}]}],\"references\":[{\"url\":\"https://drive.google.com/file/d/1X4qH-BIww5jIdoYfg9WKvX5088cpMRHY/view\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\"]},{\"url\":\"https://github.com/zeze-zeze/WindowsKernelVuln/tree/master/CVE-2023-1488\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.223374\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?id.223374\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://drive.google.com/file/d/1X4qH-BIww5jIdoYfg9WKvX5088cpMRHY/view\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\"]},{\"url\":\"https://github.com/zeze-zeze/WindowsKernelVuln/tree/master/CVE-2023-1488\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.223374\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?id.223374\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…