CVE-2023-24095 (GCVE-0-2023-24095)
Vulnerability from cvelistv5 – Published: 2023-01-23 00:00 – Updated: 2024-08-02 10:49 Unsupported When Assigned
VLAI?
Summary
TrendNet Wireless AC Easy-Upgrader TEW-820AP v1.0R, firmware version 1.01.B01 was discovered to contain a stack overflow via the submit-url parameter at /formSystemCheck. This vulnerability allows attackers to execute arbitrary code via a crafted payload. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:49:08.987Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/chunklhit/cve/blob/master/TRENDNet/TEW-820AP/05/README.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "TrendNet Wireless AC Easy-Upgrader TEW-820AP v1.0R, firmware version 1.01.B01 was discovered to contain a stack overflow via the submit-url parameter at /formSystemCheck. This vulnerability allows attackers to execute arbitrary code via a crafted payload. NOTE: This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-23T00:00:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/chunklhit/cve/blob/master/TRENDNet/TEW-820AP/05/README.md"
}
],
"tags": [
"unsupported-when-assigned"
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-24095",
"datePublished": "2023-01-23T00:00:00",
"dateReserved": "2023-01-23T00:00:00",
"dateUpdated": "2024-08-02T10:49:08.987Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:trendnet:tew-820ap_firmware:1.01.b01:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2CA79833-8AB7-4927-AC9A-8F701C8FD6C7\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:trendnet:tew-820ap:1.0r:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3A6D66CD-37D1-4941-8E8E-78237F46332C\"}]}]}]",
"cveTags": "[{\"sourceIdentifier\": \"cve@mitre.org\", \"tags\": [\"unsupported-when-assigned\"]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"TrendNet Wireless AC Easy-Upgrader TEW-820AP v1.0R, firmware version 1.01.B01 was discovered to contain a stack overflow via the submit-url parameter at /formSystemCheck. This vulnerability allows attackers to execute arbitrary code via a crafted payload. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.\"}, {\"lang\": \"es\", \"value\": \"Se descubri\\u00f3 que TrendNet Wireless AC Easy-Upgrader TEW-820AP v1.0R, versi\\u00f3n de firmware 1.01.B01, conten\\u00eda un desbordamiento de pila a trav\\u00e9s del par\\u00e1metro de env\\u00edo de URL en /formSystemCheck. Esta vulnerabilidad permite a los atacantes ejecutar c\\u00f3digo arbitrario mediante un payload manipulado. NOTA: Esta vulnerabilidad solo afecta a productos que ya no son compatibles con el fabricante.\"}]",
"id": "CVE-2023-24095",
"lastModified": "2024-11-21T07:47:23.517",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}]}",
"published": "2023-01-23T15:15:18.520",
"references": "[{\"url\": \"https://github.com/chunklhit/cve/blob/master/TRENDNet/TEW-820AP/05/README.md\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://github.com/chunklhit/cve/blob/master/TRENDNet/TEW-820AP/05/README.md\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-24095\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2023-01-23T15:15:18.520\",\"lastModified\":\"2024-11-21T07:47:23.517\",\"vulnStatus\":\"Modified\",\"cveTags\":[{\"sourceIdentifier\":\"cve@mitre.org\",\"tags\":[\"unsupported-when-assigned\"]}],\"descriptions\":[{\"lang\":\"en\",\"value\":\"TrendNet Wireless AC Easy-Upgrader TEW-820AP v1.0R, firmware version 1.01.B01 was discovered to contain a stack overflow via the submit-url parameter at /formSystemCheck. This vulnerability allows attackers to execute arbitrary code via a crafted payload. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.\"},{\"lang\":\"es\",\"value\":\"Se descubri\u00f3 que TrendNet Wireless AC Easy-Upgrader TEW-820AP v1.0R, versi\u00f3n de firmware 1.01.B01, conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro de env\u00edo de URL en /formSystemCheck. Esta vulnerabilidad permite a los atacantes ejecutar c\u00f3digo arbitrario mediante un payload manipulado. NOTA: Esta vulnerabilidad solo afecta a productos que ya no son compatibles con el fabricante.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:trendnet:tew-820ap_firmware:1.01.b01:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2CA79833-8AB7-4927-AC9A-8F701C8FD6C7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:trendnet:tew-820ap:1.0r:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3A6D66CD-37D1-4941-8E8E-78237F46332C\"}]}]}],\"references\":[{\"url\":\"https://github.com/chunklhit/cve/blob/master/TRENDNet/TEW-820AP/05/README.md\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/chunklhit/cve/blob/master/TRENDNet/TEW-820AP/05/README.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…