CVE-2023-28399 (GCVE-0-2023-28399)

Vulnerability from cvelistv5 – Published: 2023-06-01 00:00 – Updated: 2025-01-09 20:53
VLAI?
Summary
Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. ACL (Access Control List) is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC where the affected product is installed. As a result, the user may be able to destroy the system and/or execute a malicious program.
CWE
  • Incorrect permission assignment for critical resource
Assigner
Impacted products
Vendor Product Version
Contec Co., Ltd. CONPROSYS HMI System (CHS) Affected: versions prior to 3.5.3
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:38:25.168Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU93372935/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-28399",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-09T20:53:17.563643Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-732",
                "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-09T20:53:21.940Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CONPROSYS HMI System (CHS)",
          "vendor": "Contec Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "versions prior to 3.5.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. ACL (Access Control List) is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC where the affected product is installed. As a result, the user may be able to destroy the system and/or execute a malicious program."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Incorrect permission assignment for critical resource",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-01T00:00:00",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
        },
        {
          "url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
        },
        {
          "url": "https://jvn.jp/en/vu/JVNVU93372935/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2023-28399",
    "datePublished": "2023-06-01T00:00:00",
    "dateReserved": "2023-05-11T00:00:00",
    "dateUpdated": "2025-01-09T20:53:21.940Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.5.3\", \"matchCriteriaId\": \"E75EB317-708F-4E02-B521-C788934DFB97\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. ACL (Access Control List) is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC where the affected product is installed. As a result, the user may be able to destroy the system and/or execute a malicious program.\"}]",
      "id": "CVE-2023-28399",
      "lastModified": "2025-01-09T21:15:22.560",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}, {\"source\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}]}",
      "published": "2023-06-01T02:15:09.497",
      "references": "[{\"url\": \"https://jvn.jp/en/vu/JVNVU93372935/\", \"source\": \"vultures@jpcert.or.jp\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf\", \"source\": \"vultures@jpcert.or.jp\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf\", \"source\": \"vultures@jpcert.or.jp\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://jvn.jp/en/vu/JVNVU93372935/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "vultures@jpcert.or.jp",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-732\"}]}, {\"source\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-732\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-28399\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2023-06-01T02:15:09.497\",\"lastModified\":\"2025-01-09T21:15:22.560\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. ACL (Access Control List) is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC where the affected product is installed. As a result, the user may be able to destroy the system and/or execute a malicious program.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.3\",\"matchCriteriaId\":\"E75EB317-708F-4E02-B521-C788934DFB97\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/en/vu/JVNVU93372935/\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://jvn.jp/en/vu/JVNVU93372935/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://jvn.jp/en/vu/JVNVU93372935/\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T12:38:25.168Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-28399\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-09T20:53:17.563643Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-732\", \"description\": \"CWE-732 Incorrect Permission Assignment for Critical Resource\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-09T20:52:57.033Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"Contec Co., Ltd.\", \"product\": \"CONPROSYS HMI System (CHS)\", \"versions\": [{\"status\": \"affected\", \"version\": \"versions prior to 3.5.3\"}]}], \"references\": [{\"url\": \"https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf\"}, {\"url\": \"https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf\"}, {\"url\": \"https://jvn.jp/en/vu/JVNVU93372935/\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. ACL (Access Control List) is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC where the affected product is installed. As a result, the user may be able to destroy the system and/or execute a malicious program.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"Incorrect permission assignment for critical resource\"}]}], \"providerMetadata\": {\"orgId\": \"ede6fdc4-6654-4307-a26d-3331c018e2ce\", \"shortName\": \"jpcert\", \"dateUpdated\": \"2023-06-01T00:00:00\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-28399\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-01-09T20:53:21.940Z\", \"dateReserved\": \"2023-05-11T00:00:00\", \"assignerOrgId\": \"ede6fdc4-6654-4307-a26d-3331c018e2ce\", \"datePublished\": \"2023-06-01T00:00:00\", \"assignerShortName\": \"jpcert\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…