CVE-2023-28815 (GCVE-0-2023-28815)

Vulnerability from cvelistv5 – Published: 2025-10-17 11:07 – Updated: 2025-10-17 12:10
VLAI?
Summary
Some versions of Hikvision's iSecure Center Product contain insufficient parameter validation, resulting in a command injection vulnerability. Attackers may exploit this to gain platform privileges and execute arbitrary commands on the system.iSecure Center is software released for China's domestic market only, with no overseas release.
CWE
  • CWE-141 - Improper Neutralization of Parameter/Argument Delimiters
Assigner
Impacted products
Vendor Product Version
Hikvision iSecure Center Affected: V1.0.0 - V1.7.0
Create a notification for this product.
Credits
hsrc
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28815",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-17T12:10:12.884691Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-141",
                "description": "CWE-141 Improper Neutralization of Parameter/Argument Delimiters",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-17T12:10:16.930Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "iSecure Center",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.0.0 - V1.7.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "hsrc"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Some versions of Hikvision\u0027s iSecure Center Product contain insufficient parameter validation, resulting in a command injection vulnerability. Attackers may exploit this to gain platform privileges and execute arbitrary commands on the system.iSecure Center is software released for China\u0027s domestic market only, with no overseas release."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-17T11:07:26.306Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/cn/support/CybersecurityCenter/SecurityNotices/2023-04/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2023-28815",
    "datePublished": "2025-10-17T11:07:26.306Z",
    "dateReserved": "2023-03-23T19:49:08.441Z",
    "dateUpdated": "2025-10-17T12:10:16.930Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-28815\",\"sourceIdentifier\":\"hsrc@hikvision.com\",\"published\":\"2025-10-17T12:15:37.093\",\"lastModified\":\"2025-10-21T19:31:50.020\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Some versions of Hikvision\u0027s iSecure Center Product contain insufficient parameter validation, resulting in a command injection vulnerability. Attackers may exploit this to gain platform privileges and execute arbitrary commands on the system.iSecure Center is software released for China\u0027s domestic market only, with no overseas release.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"hsrc@hikvision.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-141\"}]}],\"references\":[{\"url\":\"https://www.hikvision.com/cn/support/CybersecurityCenter/SecurityNotices/2023-04/\",\"source\":\"hsrc@hikvision.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-28815\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-10-17T12:10:12.884691Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-141\", \"description\": \"CWE-141 Improper Neutralization of Parameter/Argument Delimiters\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-10-17T12:09:52.020Z\"}}], \"cna\": {\"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"hsrc\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Hikvision\", \"product\": \"iSecure Center\", \"versions\": [{\"status\": \"affected\", \"version\": \"V1.0.0 - V1.7.0\"}]}], \"references\": [{\"url\": \"https://www.hikvision.com/cn/support/CybersecurityCenter/SecurityNotices/2023-04/\"}], \"x_generator\": {\"engine\": \"cveClient/1.0.15\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Some versions of Hikvision\u0027s iSecure Center Product contain insufficient parameter validation, resulting in a command injection vulnerability. Attackers may exploit this to gain platform privileges and execute arbitrary commands on the system.iSecure Center is software released for China\u0027s domestic market only, with no overseas release.\"}], \"providerMetadata\": {\"orgId\": \"da451dce-859b-4e51-8b87-9c8b60d19b32\", \"shortName\": \"hikvision\", \"dateUpdated\": \"2025-10-17T11:07:26.306Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-28815\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-10-17T12:10:16.930Z\", \"dateReserved\": \"2023-03-23T19:49:08.441Z\", \"assignerOrgId\": \"da451dce-859b-4e51-8b87-9c8b60d19b32\", \"datePublished\": \"2025-10-17T11:07:26.306Z\", \"assignerShortName\": \"hikvision\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…