CVE-2023-30757
Vulnerability from cvelistv5
Published
2023-06-13 08:17
Modified
2024-08-02 14:37
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). The know-how protection feature in affected products does not properly update the encryption of existing program blocks when a project file is updated.
This could allow attackers with access to the project file to recover previous - yet unprotected - versions of the project without the knowledge of the know-how protection password.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-042050.pdf | Vendor Advisory |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:37:15.422Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-042050.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V19", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). The know-how protection feature in affected products does not properly update the encryption of existing program blocks when a project file is updated.\r\n\r\nThis could allow attackers with access to the project file to recover previous - yet unprotected - versions of the project without the knowledge of the know-how protection password." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.2, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-693", "description": "CWE-693: Protection Mechanism Failure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-12T11:25:35.869Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-042050.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-30757", "datePublished": "2023-06-13T08:17:10.136Z", "dateReserved": "2023-04-14T11:16:56.497Z", "dateUpdated": "2024-08-02T14:37:15.422Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-30757\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-06-13T09:15:17.323\",\"lastModified\":\"2023-12-12T10:15:09.900\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). The know-how protection feature in affected products does not properly update the encryption of existing program blocks when a project file is updated.\\r\\n\\r\\nThis could allow attackers with access to the project file to recover previous - yet unprotected - versions of the project without the knowledge of the know-how protection password.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.2,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.5,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-693\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:14.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5FD9E56C-D5F9-4AAB-AD73-F7DF5D630BF0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:15:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A5BC801E-9D78-4CD4-A457-00ABD5991515\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"C36F0E09-C1BB-4ED2-9008-99DC761FDFAA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2E1E7FB1-03AF-4AF0-B1A6-3AF65C818596\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:17:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7E0C3283-1FEA-4054-9D48-5F683FA9E4FF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"68C7D9A3-9304-4A81-A970-717E5BA1ECF1\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-042050.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.