CVE-2023-31238
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:53:29.691Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.60" } ] }, { "defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.60" } ] }, { "defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.60" } ] }, { "defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.60" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "CWE-732: Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T09:59:42.265Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-31238", "datePublished": "2023-06-13T08:17:13.351Z", "dateReserved": "2023-04-26T17:03:00.579Z", "dateUpdated": "2024-08-02T14:53:29.691Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-31238\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-06-13T09:15:18.093\",\"lastModified\":\"2024-01-09T10:15:15.210\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.2,\"impactScore\":2.5},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:L/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.3,\"impactScore\":3.7}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:q200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CC2EA3F6-418C-49A4-B23C-E7BD56395466\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:q200_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.70\",\"matchCriteriaId\":\"D1D626C5-92BF-4C9B-9EF2-24347CF24491\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
icsa-23-348-13
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "The web server of SICAM Q100 devices, versions before V2.60, contains a Cross Site Request Forgery (CSRF) vulnerability and is missing cookie protection flags. This could allow an attacker to perform arbitrary actions on the device on behalf of a legitimate user, or impersonate that user.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design.\nSiemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. \nAs a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.\n\nRecommended security guidelines can be found at:\n\nhttps://www.siemens.com/gridsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-480095: Vulnerabilities in the Web Interface of SICAM Q100 Devices before V2.60 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-480095.json" }, { "category": "self", "summary": "SSA-480095: Vulnerabilities in the Web Interface of SICAM Q100 Devices before V2.60 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-480095.html" }, { "category": "self", "summary": "SSA-480095: Vulnerabilities in the Web Interface of SICAM Q100 Devices before V2.60 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" }, { "category": "self", "summary": "SSA-480095: Vulnerabilities in the Web Interface of SICAM Q100 Devices before V2.60 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-480095.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-348-13 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-348-13.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-348-13 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-13" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SICAM Q100 Devices", "tracking": { "current_release_date": "2023-12-12T00:00:00Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-23-348-13", "initial_release_date": "2023-12-12T00:00:00Z", "revision_history": [ { "date": "2023-12-12T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2.60", "product": { "name": "POWER METER SICAM Q100 (7KG9501-0AA01-2AA1)", "product_id": "1", "product_identification_helper": { "model_numbers": [ "7KG9501-0AA01-2AA1" ] } } } ], "category": "product_name", "name": "POWER METER SICAM Q100 (7KG9501-0AA01-2AA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2.60", "product": { "name": "POWER METER SICAM Q100 (7KG9501-0AA31-2AA1)", "product_id": "2", "product_identification_helper": { "model_numbers": [ "7KG9501-0AA31-2AA1" ] } } } ], "category": "product_name", "name": "POWER METER SICAM Q100 (7KG9501-0AA31-2AA1)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-30901", "cwe": { "id": "CWE-352", "name": "Cross-Site Request Forgery (CSRF)" }, "notes": [ { "category": "summary", "text": "The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2" ] }, "remediations": [ { "category": "mitigation", "details": "CVE-2023-30901: Do not access links from untrusted sources while logged in at affected devices", "product_ids": [ "1", "2" ] }, { "category": "vendor_fix", "details": "Update to V2.60 or later version", "product_ids": [ "1", "2" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2" ] } ], "title": "CVE-2023-30901" }, { "cve": "CVE-2023-31238", "cwe": { "id": "CWE-732", "name": "Incorrect Permission Assignment for Critical Resource" }, "notes": [ { "category": "summary", "text": "Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V2.60 or later version", "product_ids": [ "1", "2" ] }, { "category": "workaround", "details": "CVE-2023-31238: Restrict access to port 443/tcp to trusted IP addresses only", "product_ids": [ "1", "2" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2" ] } ], "title": "CVE-2023-31238" } ] }
icsa-23-166-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "summary", "text": "Multiple vulnerabilities were identified in the webserver of Q200 devices. These include Cross Site Request Forgery (CSRF), session fixation, missing secure flags in HTTP cookies and memory corruption issues due to missing input validation that could lead to remote code execution. \n\nSiemens has released an update for POWER METER SICAM Q200 family and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design.\nSiemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. \nAs a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.\n\nRecommended security guidelines can be found at:\n\nhttps://www.siemens.com/gridsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimizing network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locating control system networks and remote devices behind firewalls and isolating them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, using more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "\u200bNo known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have low attack complexity.", "title": "Exploitability" } ], "publisher": { "category": "other", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-887249: Multiple Vulnerabilities in the Web Interface of SICAM Q200 Devices - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-887249.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-166-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-166-03.json" }, { "category": "self", "summary": "SSA-887249: Multiple Vulnerabilities in the Web Interface of SICAM Q200 Devices - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-887249.html" }, { "category": "self", "summary": "SSA-887249: Multiple Vulnerabilities in the Web Interface of SICAM Q200 Devices - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf" }, { "category": "self", "summary": "SSA-887249: Multiple Vulnerabilities in the Web Interface of SICAM Q200 Devices - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-887249.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-166-03 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SICAM Q200 Devices", "tracking": { "current_release_date": "2023-06-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-23-166-03", "initial_release_date": "2023-06-13T00:00:00.000000Z", "revision_history": [ { "date": "2023-06-13T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV2.70", "product": { "name": "POWER METER SICAM Q200 family", "product_id": "1" } } ], "category": "product_name", "name": "POWER METER SICAM Q200 family" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-43398", "cwe": { "id": "CWE-384", "name": "Session Fixation" }, "notes": [ { "category": "summary", "text": "Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user\u0027s account through the activated session.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Do not access links from untrusted sources while logged in at Q200 devices", "product_ids": [ "1" ] }, { "category": "mitigation", "details": "Restrict access to port 443/tcp to trusted IP addresses only", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V2.70 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109743592/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-43398" }, { "cve": "CVE-2022-43439", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the Language-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Do not access links from untrusted sources while logged in at Q200 devices", "product_ids": [ "1" ] }, { "category": "mitigation", "details": "Restrict access to port 443/tcp to trusted IP addresses only", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V2.70 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109743592/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.9, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-43439" }, { "cve": "CVE-2022-43545", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the RecordType-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Do not access links from untrusted sources while logged in at Q200 devices", "product_ids": [ "1" ] }, { "category": "mitigation", "details": "Restrict access to port 443/tcp to trusted IP addresses only", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V2.70 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109743592/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.9, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-43545" }, { "cve": "CVE-2022-43546", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the EndTime-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Do not access links from untrusted sources while logged in at Q200 devices", "product_ids": [ "1" ] }, { "category": "mitigation", "details": "Restrict access to port 443/tcp to trusted IP addresses only", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V2.70 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109743592/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.9, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-43546" }, { "cve": "CVE-2023-30901", "cwe": { "id": "CWE-352", "name": "Cross-Site Request Forgery (CSRF)" }, "notes": [ { "category": "summary", "text": "The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Do not access links from untrusted sources while logged in at Q200 devices", "product_ids": [ "1" ] }, { "category": "mitigation", "details": "Restrict access to port 443/tcp to trusted IP addresses only", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V2.70 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109743592/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-30901" }, { "cve": "CVE-2023-31238", "cwe": { "id": "CWE-732", "name": "Incorrect Permission Assignment for Critical Resource" }, "notes": [ { "category": "summary", "text": "Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Do not access links from untrusted sources while logged in at Q200 devices", "product_ids": [ "1" ] }, { "category": "mitigation", "details": "Restrict access to port 443/tcp to trusted IP addresses only", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V2.70 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109743592/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-31238" } ] }
ghsa-3gq4-h9hg-9898
Vulnerability from github
A vulnerability has been identified in POWER METER SICAM Q200 family (All versions < V2.70). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user.
{ "affected": [], "aliases": [ "CVE-2023-31238" ], "database_specific": { "cwe_ids": [ "CWE-732" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2023-06-13T09:15:18Z", "severity": "MODERATE" }, "details": "A vulnerability has been identified in POWER METER SICAM Q200 family (All versions \u003c V2.70). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user.", "id": "GHSA-3gq4-h9hg-9898", "modified": "2023-12-12T12:30:43Z", "published": "2023-06-13T09:30:19Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-31238" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:L/A:L", "type": "CVSS_V3" } ] }
var-202306-0889
Vulnerability from variot
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user. Siemens' q200 A firmware vulnerability related to improper assignment of permissions to critical resources.Information may be obtained and information may be tampered with. SICAM Q200 is a multifunctional device for detection, reporting and analysis of measured values and events
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202306-0889", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "q200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.70" }, { "model": "q200", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "q200 firmware 2.70" }, { "model": "q200", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "q200", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sicam q200", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "2.70" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-48550" }, { "db": "JVNDB", "id": "JVNDB-2023-009050" }, { "db": "NVD", "id": "CVE-2023-31238" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:q200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.70", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:q200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-31238" } ] }, "cve": "CVE-2023-31238", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "HIGH", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "CNVD-2023-48550", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:H/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "HIGH", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.2, "impactScore": 2.5, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "HIGH", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "LOW", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.3, "impactScore": 3.7, "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:L/A:L", "version": "3.1" }, { "attackComplexity": "High", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2023-31238", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-31238", "trust": 1.8, "value": "MEDIUM" }, { "author": "productcert@siemens.com", "id": "CVE-2023-31238", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNVD", "id": "CNVD-2023-48550", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202306-885", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-48550" }, { "db": "JVNDB", "id": "JVNDB-2023-009050" }, { "db": "CNNVD", "id": "CNNVD-202306-885" }, { "db": "NVD", "id": "CVE-2023-31238" }, { "db": "NVD", "id": "CVE-2023-31238" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user. Siemens\u0027 q200 A firmware vulnerability related to improper assignment of permissions to critical resources.Information may be obtained and information may be tampered with. SICAM Q200 is a multifunctional device for detection, reporting and analysis of measured values \u200b\u200band events", "sources": [ { "db": "NVD", "id": "CVE-2023-31238" }, { "db": "JVNDB", "id": "JVNDB-2023-009050" }, { "db": "CNVD", "id": "CNVD-2023-48550" }, { "db": "VULMON", "id": "CVE-2023-31238" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-31238", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-887249", "trust": 3.1 }, { "db": "SIEMENS", "id": "SSA-480095", "trust": 1.0 }, { "db": "ICS CERT", "id": "ICSA-23-166-03", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-23-348-12", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU98271228", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU99464755", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-009050", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-48550", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202306-885", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-31238", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-48550" }, { "db": "VULMON", "id": "CVE-2023-31238" }, { "db": "JVNDB", "id": "JVNDB-2023-009050" }, { "db": "CNNVD", "id": "CNNVD-202306-885" }, { "db": "NVD", "id": "CVE-2023-31238" } ] }, "id": "VAR-202306-0889", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-48550" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-48550" } ] }, "last_update_date": "2024-01-17T19:14:06.519000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SICAM Q200 Privilege Assignment Error Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/433496" }, { "title": "Siemens POWER METER SICAM Security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=243028" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-48550" }, { "db": "CNNVD", "id": "CNNVD-202306-885" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-732", "trust": 1.0 }, { "problemtype": "Improper permission assignment for critical resources (CWE-732) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-009050" }, { "db": "NVD", "id": "CVE-2023-31238" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu99464755/" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu98271228/index.html" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-31238" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-03" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-12" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-887249.html" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-31238/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-48550" }, { "db": "VULMON", "id": "CVE-2023-31238" }, { "db": "JVNDB", "id": "JVNDB-2023-009050" }, { "db": "CNNVD", "id": "CNNVD-202306-885" }, { "db": "NVD", "id": "CVE-2023-31238" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-48550" }, { "db": "VULMON", "id": "CVE-2023-31238" }, { "db": "JVNDB", "id": "JVNDB-2023-009050" }, { "db": "CNNVD", "id": "CNNVD-202306-885" }, { "db": "NVD", "id": "CVE-2023-31238" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-14T00:00:00", "db": "CNVD", "id": "CNVD-2023-48550" }, { "date": "2023-06-13T00:00:00", "db": "VULMON", "id": "CVE-2023-31238" }, { "date": "2023-12-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-009050" }, { "date": "2023-06-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202306-885" }, { "date": "2023-06-13T09:15:18.093000", "db": "NVD", "id": "CVE-2023-31238" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-06-14T00:00:00", "db": "CNVD", "id": "CNVD-2023-48550" }, { "date": "2023-06-13T00:00:00", "db": "VULMON", "id": "CVE-2023-31238" }, { "date": "2023-12-21T06:21:00", "db": "JVNDB", "id": "JVNDB-2023-009050" }, { "date": "2023-06-27T00:00:00", "db": "CNNVD", "id": "CNNVD-202306-885" }, { "date": "2024-01-09T10:15:15.210000", "db": "NVD", "id": "CVE-2023-31238" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-885" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens\u0027 \u00a0q200\u00a0 Improper Permission Assignment Vulnerability for Critical Resources in Firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-009050" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202306-885" } ], "trust": 0.6 } }
gsd-2023-31238
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2023-31238", "id": "GSD-2023-31238" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-31238" ], "details": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user.", "id": "GSD-2023-31238", "modified": "2023-12-13T01:20:29.924522Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2023-31238", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "POWER METER SICAM Q100", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V2.60" }, { "version_affected": "=", "version_value": "All versions \u003c V2.60" }, { "version_affected": "=", "version_value": "All versions \u003c V2.60" }, { "version_affected": "=", "version_value": "All versions \u003c V2.60" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user." } ] }, "impact": { "cvss": [ { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-732", "lang": "eng", "value": "CWE-732: Incorrect Permission Assignment for Critical Resource" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" } ] } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:q200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1D626C5-92BF-4C9B-9EF2-24347CF24491", "versionEndExcluding": "2.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:q200:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC2EA3F6-418C-49A4-B23C-E7BD56395466", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user." } ], "id": "CVE-2023-31238", "lastModified": "2024-01-09T10:15:15.210", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 2.5, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 1.3, "impactScore": 3.7, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2023-06-13T09:15:18.093", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-732" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-732" } ], "source": "productcert@siemens.com", "type": "Secondary" } ] } } } }
wid-sec-w-2023-1431
Vulnerability from csaf_certbund
Notes
{ "document": { "aggregate_severity": { "text": "hoch" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "Siemens SICAM ist eine Produktfamilie von SCADA-Systemen f\u00fcr den Betrieb von industriellen Prozessen.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein Angreifer kann mehrere Schwachstellen in Siemens SICAM ausnutzen, um Sicherheitsvorkehrungen zu umgehen und Code auszuf\u00fchren.", "title": "Angriff" }, { "category": "general", "text": "- Sonstiges", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2023-1431 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2023/wid-sec-w-2023-1431.json" }, { "category": "self", "summary": "WID-SEC-2023-1431 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2023-1431" }, { "category": "external", "summary": "Siemens Security Advisory by Siemens ProductCERT vom 2023-06-12", "url": "https://cert-portal.siemens.com/productcert/html/ssa-887249.html" }, { "category": "external", "summary": "Siemens Security Advisory SSA-480095 vom 2023-12-12", "url": "https://cert-portal.siemens.com/productcert/html/ssa-480095.html" } ], "source_lang": "en-US", "title": "Siemens SICAM: Mehrere Schwachstellen", "tracking": { "current_release_date": "2023-12-11T23:00:00.000+00:00", "generator": { "date": "2024-02-15T17:30:46.970+00:00", "engine": { "name": "BSI-WID", "version": "1.3.0" } }, "id": "WID-SEC-W-2023-1431", "initial_release_date": "2023-06-12T22:00:00.000+00:00", "revision_history": [ { "date": "2023-06-12T22:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" }, { "date": "2023-12-11T23:00:00.000+00:00", "number": "2", "summary": "Neue Updates von Siemens aufgenommen" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_name", "name": "Siemens SICAM", "product": { "name": "Siemens SICAM", "product_id": "T019770", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:-" } } }, { "category": "product_name", "name": "Siemens SICAM Q200 \u003c V2.70", "product": { "name": "Siemens SICAM Q200 \u003c V2.70", "product_id": "T028072", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:q200__v2.70" } } } ], "category": "product_name", "name": "SICAM" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-43398", "notes": [ { "category": "description", "text": "Es existiert eine Schwachstelle in Siemens SICAM. Das Sitzungs-Cookie wird nach dem Login/Logout nicht erneuert und benutzerdefinierte Sitzungs-Cookie werden akzeptiert. Ein Angreifer kann das gespeicherte Sitzungs-Cookie eines Benutzers \u00fcberschreiben und Zugriff auf das Konto des Benutzers erhalten. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich." } ], "product_status": { "known_affected": [ "T019770" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-43398" }, { "cve": "CVE-2022-43546", "notes": [ { "category": "description", "text": "Es existiert eine Schwachstelle in Siemens SICAM. Language-Parameter, RecordType-Parameter und EndTime-Parameter werden in Anfragen an das Webinterface auf Port 443/tcp nicht sachgem\u00e4\u00df validiert. Ein authentisierter Angreifer kann diese Schwachstelle ausnutzen, um das Ger\u00e4t zum Absturz zu bringen oder beliebigen Code auf dem Ger\u00e4t auszuf\u00fchren." } ], "product_status": { "known_affected": [ "T019770" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-43546" }, { "cve": "CVE-2022-43545", "notes": [ { "category": "description", "text": "Es existiert eine Schwachstelle in Siemens SICAM. Language-Parameter, RecordType-Parameter und EndTime-Parameter werden in Anfragen an das Webinterface auf Port 443/tcp nicht sachgem\u00e4\u00df validiert. Ein authentisierter Angreifer kann diese Schwachstelle ausnutzen, um das Ger\u00e4t zum Absturz zu bringen oder beliebigen Code auf dem Ger\u00e4t auszuf\u00fchren." } ], "product_status": { "known_affected": [ "T019770" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-43545" }, { "cve": "CVE-2022-43439", "notes": [ { "category": "description", "text": "Es existiert eine Schwachstelle in Siemens SICAM. Language-Parameter, RecordType-Parameter und EndTime-Parameter werden in Anfragen an das Webinterface auf Port 443/tcp nicht sachgem\u00e4\u00df validiert. Ein authentisierter Angreifer kann diese Schwachstelle ausnutzen, um das Ger\u00e4t zum Absturz zu bringen oder beliebigen Code auf dem Ger\u00e4t auszuf\u00fchren." } ], "product_status": { "known_affected": [ "T019770" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-43439" }, { "cve": "CVE-2023-30901", "notes": [ { "category": "description", "text": "Es existiert eine Schwachstelle in Siemens SICAM. Die Webschnittstelle der betroffenen Ger\u00e4te ist anf\u00e4llig f\u00fcr Cross-Site Request Forgery-Angriffe. Ein Angreifer kann diese Schwachstelle ausnutzen, um im Namen des Opfers beliebige Aktionen auf dem Ger\u00e4t durchzuf\u00fchren. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich." } ], "product_status": { "known_affected": [ "T019770" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-30901" }, { "cve": "CVE-2023-31238", "notes": [ { "category": "description", "text": "Es existiert eine Schwachstelle in Siemens SICAM. Wenn sie die Standardeinstellungen verwendet werden fehlen die Cookie-Schutz-Flags. Ein Angreifer der Zugriff auf ein Sitzungs-Token erh\u00e4lt, kann sich damit als legitimer Anwendungsbenutzer ausgeben. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich." } ], "product_status": { "known_affected": [ "T019770" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-31238" } ] }
ssa-480095
Vulnerability from csaf_siemens
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "The web server of SICAM Q100 devices, versions before V2.60, contains a Cross Site Request Forgery (CSRF) vulnerability and is missing cookie protection flags. This could allow an attacker to perform arbitrary actions on the device on behalf of a legitimate user, or impersonate that user.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design.\nSiemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. \nAs a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.\n\nRecommended security guidelines can be found at:\n\nhttps://www.siemens.com/gridsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-480095: Vulnerabilities in the Web Interface of SICAM Q100 Devices before V2.60 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-480095.html" }, { "category": "self", "summary": "SSA-480095: Vulnerabilities in the Web Interface of SICAM Q100 Devices before V2.60 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-480095.json" }, { "category": "self", "summary": "SSA-480095: Vulnerabilities in the Web Interface of SICAM Q100 Devices before V2.60 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" }, { "category": "self", "summary": "SSA-480095: Vulnerabilities in the Web Interface of SICAM Q100 Devices before V2.60 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-480095.txt" } ], "title": "SSA-480095: Vulnerabilities in the Web Interface of SICAM Q100 Devices before V2.60", "tracking": { "current_release_date": "2024-01-09T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-480095", "initial_release_date": "2023-12-12T00:00:00Z", "revision_history": [ { "date": "2023-12-12T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2024-01-09T00:00:00Z", "legacy_version": "1.1", "number": "2", "summary": "Added legacy Q100 device models (-0AA1) which are also affected and provide the same fix version" } ], "status": "interim", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2.60", "product": { "name": "POWER METER SICAM Q100 (7KG9501-0AA01-0AA1)", "product_id": "1", "product_identification_helper": { "model_numbers": [ "7KG9501-0AA01-0AA1" ] } } } ], "category": "product_name", "name": "POWER METER SICAM Q100 (7KG9501-0AA01-0AA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2.60", "product": { "name": "POWER METER SICAM Q100 (7KG9501-0AA01-2AA1)", "product_id": "2", "product_identification_helper": { "model_numbers": [ "7KG9501-0AA01-2AA1" ] } } } ], "category": "product_name", "name": "POWER METER SICAM Q100 (7KG9501-0AA01-2AA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2.60", "product": { "name": "POWER METER SICAM Q100 (7KG9501-0AA31-0AA1)", "product_id": "3", "product_identification_helper": { "model_numbers": [ "7KG9501-0AA31-0AA1" ] } } } ], "category": "product_name", "name": "POWER METER SICAM Q100 (7KG9501-0AA31-0AA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2.60", "product": { "name": "POWER METER SICAM Q100 (7KG9501-0AA31-2AA1)", "product_id": "4", "product_identification_helper": { "model_numbers": [ "7KG9501-0AA31-2AA1" ] } } } ], "category": "product_name", "name": "POWER METER SICAM Q100 (7KG9501-0AA31-2AA1)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-30901", "cwe": { "id": "CWE-352", "name": "Cross-Site Request Forgery (CSRF)" }, "notes": [ { "category": "summary", "text": "The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4" ] }, "remediations": [ { "category": "mitigation", "details": "CVE-2023-30901: Do not access links from untrusted sources while logged in at affected devices", "product_ids": [ "1", "2", "3", "4" ] }, { "category": "vendor_fix", "details": "Update to V2.60 or later version", "product_ids": [ "1", "2", "3", "4" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "4", "3", "1", "2" ] } ], "title": "CVE-2023-30901" }, { "cve": "CVE-2023-31238", "cwe": { "id": "CWE-732", "name": "Incorrect Permission Assignment for Critical Resource" }, "notes": [ { "category": "summary", "text": "Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V2.60 or later version", "product_ids": [ "1", "2", "3", "4" ] }, { "category": "workaround", "details": "CVE-2023-31238: Restrict access to port 443/tcp to trusted IP addresses only", "product_ids": [ "1", "2", "3", "4" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "4", "3", "1", "2" ] } ], "title": "CVE-2023-31238" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.