var-202306-0889
Vulnerability from variot

A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user. Siemens' q200 A firmware vulnerability related to improper assignment of permissions to critical resources.Information may be obtained and information may be tampered with. SICAM Q200 is a multifunctional device for detection, reporting and analysis of measured values ​​and events

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202306-0889",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "q200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.70"
      },
      {
        "model": "q200",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": "q200  firmware  2.70"
      },
      {
        "model": "q200",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "q200",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "sicam q200",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "2.70"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-48550"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009050"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-31238"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:q200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.70",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:q200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-31238"
      }
    ]
  },
  "cve": "CVE-2023-31238",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "HIGH",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "CNVD-2023-48550",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:H/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 2.2,
            "impactScore": 2.5,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "productcert@siemens.com",
            "availabilityImpact": "LOW",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.3,
            "impactScore": 3.7,
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "High",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 4.8,
            "baseSeverity": "Medium",
            "confidentialityImpact": "Low",
            "exploitabilityScore": null,
            "id": "CVE-2023-31238",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2023-31238",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2023-31238",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-48550",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202306-885",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-48550"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009050"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202306-885"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-31238"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-31238"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user. Siemens\u0027 q200 A firmware vulnerability related to improper assignment of permissions to critical resources.Information may be obtained and information may be tampered with. SICAM Q200 is a multifunctional device for detection, reporting and analysis of measured values \u200b\u200band events",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-31238"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009050"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-48550"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-31238"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-31238",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-887249",
        "trust": 3.1
      },
      {
        "db": "SIEMENS",
        "id": "SSA-480095",
        "trust": 1.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-166-03",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-348-12",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU98271228",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU99464755",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009050",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-48550",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202306-885",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-31238",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-48550"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-31238"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009050"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202306-885"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-31238"
      }
    ]
  },
  "id": "VAR-202306-0889",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-48550"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-48550"
      }
    ]
  },
  "last_update_date": "2024-01-17T19:14:06.519000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Siemens SICAM Q200 Privilege Assignment Error Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/433496"
      },
      {
        "title": "Siemens POWER METER SICAM Security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=243028"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-48550"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202306-885"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-732",
        "trust": 1.0
      },
      {
        "problemtype": "Improper permission assignment for critical resources (CWE-732) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009050"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-31238"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu99464755/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu98271228/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-31238"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-03"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-12"
      },
      {
        "trust": 0.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-887249.html"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-31238/"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-48550"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-31238"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009050"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202306-885"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-31238"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-48550"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-31238"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009050"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202306-885"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-31238"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-06-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-48550"
      },
      {
        "date": "2023-06-13T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-31238"
      },
      {
        "date": "2023-12-04T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-009050"
      },
      {
        "date": "2023-06-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202306-885"
      },
      {
        "date": "2023-06-13T09:15:18.093000",
        "db": "NVD",
        "id": "CVE-2023-31238"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-06-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-48550"
      },
      {
        "date": "2023-06-13T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-31238"
      },
      {
        "date": "2023-12-21T06:21:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-009050"
      },
      {
        "date": "2023-06-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202306-885"
      },
      {
        "date": "2024-01-09T10:15:15.210000",
        "db": "NVD",
        "id": "CVE-2023-31238"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202306-885"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens\u0027 \u00a0q200\u00a0 Improper Permission Assignment Vulnerability for Critical Resources in Firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009050"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202306-885"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.