CVE-2023-3127
Vulnerability from cvelistv5
Published
2023-07-11 21:06
Modified
2024-10-22 20:31
Summary
Improper Authentication in iSTAR
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:48:07.288Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-192-02"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-3127",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-22T20:30:47.341803Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-22T20:31:09.969Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "iSTAR Ultra",
          "vendor": "Sensormatic Electronics, a subsidiary of Johnson Controls, Inc.",
          "versions": [
            {
              "lessThan": "6.9.2 CU01",
              "status": "affected",
              "version": "\u003e6.8.6",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "iSTAR Ultra LT",
          "vendor": "Sensormatic Electronics, a subsidiary of Johnson Controls, Inc.",
          "versions": [
            {
              "lessThan": "6.9.2 CU01",
              "status": "affected",
              "version": "\u003e6.8.6",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "iSTAR Ultra G2",
          "vendor": "Sensormatic Electronics, a subsidiary of Johnson Controls, Inc.",
          "versions": [
            {
              "lessThan": "6.9.2 CU01",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "iSTAR Edge G2",
          "vendor": "Sensormatic Electronics, a subsidiary of Johnson Controls, Inc.",
          "versions": [
            {
              "lessThan": "6.9.2 CU01",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2023-07-11T21:03:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An unauthenticated user could log into iSTAR Ultra, iSTAR Ultra LT, iSTAR Ultra G2, and iSTAR Edge G2 with administrator rights."
            }
          ],
          "value": "An unauthenticated user could log into iSTAR Ultra, iSTAR Ultra LT, iSTAR Ultra G2, and iSTAR Edge G2 with administrator rights."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-07-11T21:06:29.003Z",
        "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "shortName": "jci"
      },
      "references": [
        {
          "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-192-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade iSTAR Ultra, iSTAR Ultra LT, iSTAR Ultra G2, and iSTAR Edge G2 firmware to version 6.9.2 CU01.\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "Upgrade iSTAR Ultra, iSTAR Ultra LT, iSTAR Ultra G2, and iSTAR Edge G2 firmware to version 6.9.2 CU01.\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper Authentication in iSTAR",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
    "assignerShortName": "jci",
    "cveId": "CVE-2023-3127",
    "datePublished": "2023-07-11T21:06:29.003Z",
    "dateReserved": "2023-06-06T14:51:53.713Z",
    "dateUpdated": "2024-10-22T20:31:09.969Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-3127\",\"sourceIdentifier\":\"productsecurity@jci.com\",\"published\":\"2023-07-11T22:15:09.907\",\"lastModified\":\"2023-07-20T01:49:31.853\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"An unauthenticated user could log into iSTAR Ultra, iSTAR Ultra LT, iSTAR Ultra G2, and iSTAR Edge G2 with administrator rights.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"productsecurity@jci.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:L\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.6,\"impactScore\":5.3}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]},{\"source\":\"productsecurity@jci.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:johnsoncontrols:istar_ultra:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F89B3465-8274-49E5-8290-1893B4C2AC07\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:johnsoncontrols:istar_ultra_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.8.6\",\"versionEndExcluding\":\"6.9.2\",\"matchCriteriaId\":\"C49B542F-166F-4385-B910-705064C5B109\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:johnsoncontrols:istar_ultra_firmware:6.9.2:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"7AF26AC6-083F-4BB3-86AF-8730E2BFD397\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:johnsoncontrols:istar_ultra_lt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A759A7FA-5AEA-48D8-B40E-B0DA7223F0F4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:johnsoncontrols:istar_ultra_lt_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.8.6\",\"versionEndExcluding\":\"6.9.2\",\"matchCriteriaId\":\"C9D2D8D5-A67D-45DD-A718-37C29D633931\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:johnsoncontrols:istar_ultra_lt_firmware:6.9.2:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"5294AD55-D524-4E5A-ACEC-7685974A9415\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:johnsoncontrols:istar_ultra_g2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A148D700-5542-473A-B88F-849180658787\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:johnsoncontrols:istar_ultra_g2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.9.2\",\"matchCriteriaId\":\"85B7CE5A-A2A1-4433-B85A-8B6255B3D657\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:johnsoncontrols:istar_ultra_g2_firmware:6.9.2:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"7A3A4BDF-12FE-43C9-8CD4-0CA764E08175\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:johnsoncontrols:edge_g2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"95BBCCE7-3098-41B0-A388-53E3DA9A29B9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:johnsoncontrols:edge_g2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.9.2\",\"matchCriteriaId\":\"6D26CC65-9CCF-41A5-BC1B-2AAFAF9393E1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:johnsoncontrols:edge_g2_firmware:6.9.2:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"C629C7CF-4372-494D-8B1C-CC4795356E03\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-23-192-02\",\"source\":\"productsecurity@jci.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.johnsoncontrols.com/cyber-solutions/security-advisories\",\"source\":\"productsecurity@jci.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.