CVE-2023-39509 (GCVE-0-2023-39509)

Vulnerability from cvelistv5 – Published: 2023-12-18 12:55 – Updated: 2024-08-02 18:10
VLAI?
Summary
A command injection vulnerability exists in Bosch IP cameras that allows an authenticated user with administrative rights to run arbitrary commands on the OS of the camera.
CWE
  • CWE-20 - Improper Input Validation
Assigner
References
Impacted products
Vendor Product Version
Bosch Camera Firmware Affected: 0 , ≤ 8.90 (custom)
Create a notification for this product.
    Bosch Camera Firmware Affected: 8.20 , ≤ 8.81 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T18:10:21.172Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-638184-BT.html",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-638184-BT.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "CPP13"
          ],
          "product": "Camera Firmware",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThanOrEqual": "8.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "CPP14"
          ],
          "product": "Camera Firmware",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThanOrEqual": "8.81",
              "status": "affected",
              "version": "8.20",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A command injection vulnerability exists in Bosch IP cameras that allows an authenticated user with administrative rights to run arbitrary commands on the OS of the camera."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en-US"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-12-18T12:55:14.660Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-638184-BT.html",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-638184-BT.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2023-39509",
    "datePublished": "2023-12-18T12:55:14.660Z",
    "dateReserved": "2023-08-03T09:31:24.611Z",
    "dateUpdated": "2024-08-02T18:10:21.172Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:cpp13_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"8.90\", \"matchCriteriaId\": \"76747B70-CBD6-4072-A9C7-EB89017494E9\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:bosch:cpp13:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"80149FF9-3C6D-4C80-8257-CEB2BE8B0DCA\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:cpp14_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"8.20\", \"versionEndIncluding\": \"8.81\", \"matchCriteriaId\": \"5233DED6-3919-42BB-ABE0-1907AB33F232\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:bosch:cpp14:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B7872B92-4708-4522-BA8F-5BE941D169AC\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A command injection vulnerability exists in Bosch IP cameras that allows an authenticated user with administrative rights to run arbitrary commands on the OS of the camera.\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad de inyecci\\u00f3n de comandos en las c\\u00e1maras IP de Bosch que permite a un usuario autenticado con derechos administrativos ejecutar comandos arbitrarios en el sistema operativo de la c\\u00e1mara.\"}]",
      "id": "CVE-2023-39509",
      "lastModified": "2024-11-21T08:15:33.903",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"psirt@bosch.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 5.9}]}",
      "published": "2023-12-18T13:15:07.210",
      "references": "[{\"url\": \"https://psirt.bosch.com/security-advisories/BOSCH-SA-638184-BT.html\", \"source\": \"psirt@bosch.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://psirt.bosch.com/security-advisories/BOSCH-SA-638184-BT.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "psirt@bosch.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"psirt@bosch.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-20\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-77\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-39509\",\"sourceIdentifier\":\"psirt@bosch.com\",\"published\":\"2023-12-18T13:15:07.210\",\"lastModified\":\"2024-11-21T08:15:33.903\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A command injection vulnerability exists in Bosch IP cameras that allows an authenticated user with administrative rights to run arbitrary commands on the OS of the camera.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de inyecci\u00f3n de comandos en las c\u00e1maras IP de Bosch que permite a un usuario autenticado con derechos administrativos ejecutar comandos arbitrarios en el sistema operativo de la c\u00e1mara.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:cpp13_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"8.90\",\"matchCriteriaId\":\"76747B70-CBD6-4072-A9C7-EB89017494E9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:cpp13:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"80149FF9-3C6D-4C80-8257-CEB2BE8B0DCA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:cpp14_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.20\",\"versionEndIncluding\":\"8.81\",\"matchCriteriaId\":\"5233DED6-3919-42BB-ABE0-1907AB33F232\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:cpp14:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B7872B92-4708-4522-BA8F-5BE941D169AC\"}]}]}],\"references\":[{\"url\":\"https://psirt.bosch.com/security-advisories/BOSCH-SA-638184-BT.html\",\"source\":\"psirt@bosch.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://psirt.bosch.com/security-advisories/BOSCH-SA-638184-BT.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…