CVE-2023-41032
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-08-02 18:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.253), Parasolid V35.1 (All versions < V35.1.184), Parasolid V36.0 (All versions < V36.0.142), Simcenter Femap V2301 (All versions < V2301.0003), Simcenter Femap V2306 (All versions < V2306.0001). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21263)
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-190839.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-887122.pdf | Vendor Advisory | |
productcert@siemens.com | https://www.bentley.com/advisories/be-2023-0004/ | Third Party Advisory |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T18:46:11.388Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-190839.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887122.pdf" }, { "tags": [ "x_transferred" ], "url": "https://www.bentley.com/advisories/be-2023-0004/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Parasolid V34.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V34.1.258" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V35.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V35.0.253" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V35.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V35.1.184" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V36.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V36.0.142" } ] }, { "defaultStatus": "unknown", "product": "Simcenter Femap V2301", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2301.0003" } ] }, { "defaultStatus": "unknown", "product": "Simcenter Femap V2306", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2306.0001" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.253), Parasolid V35.1 (All versions \u003c V35.1.184), Parasolid V36.0 (All versions \u003c V36.0.142), Simcenter Femap V2301 (All versions \u003c V2301.0003), Simcenter Femap V2306 (All versions \u003c V2306.0001). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21263)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-14T11:03:42.705Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-190839.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887122.pdf" }, { "url": "https://www.bentley.com/advisories/be-2023-0004/" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-41032", "datePublished": "2023-09-12T09:32:33.893Z", "dateReserved": "2023-08-22T15:41:08.129Z", "dateUpdated": "2024-08-02T18:46:11.388Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-41032\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-09-12T10:15:29.690\",\"lastModified\":\"2024-02-16T14:25:44.303\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.253), Parasolid V35.1 (All versions \u003c V35.1.184), Parasolid V36.0 (All versions \u003c V36.0.142), Simcenter Femap V2301 (All versions \u003c V2301.0003), Simcenter Femap V2306 (All versions \u003c V2306.0001). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21263)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Parasolid V34.1 (todas las versiones \u0026lt; V34.1.258), Parasolid V35.0 (todas las versiones \u0026lt; V35.0.253), Parasolid V35.1 (todas las versiones \u0026lt; V35.1.184), Parasolid V36.0 (todas las versiones \u0026lt; V36.0.142). La aplicaci\u00f3n afectada contiene una escritura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analiza archivos X_T especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-21263)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"34.1\",\"versionEndExcluding\":\"34.1.258\",\"matchCriteriaId\":\"E7751190-C386-451B-88B5-4BB4DCBFCE44\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"35.0\",\"versionEndExcluding\":\"35.0.253\",\"matchCriteriaId\":\"0CC7B08D-C9CF-4B68-90A8-8D2DF3CB5154\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"35.1\",\"versionEndExcluding\":\"35.1.184\",\"matchCriteriaId\":\"3881FB7A-8951-48F6-A948-7C670C11B2B3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"36.0\",\"versionEndExcluding\":\"36.0.142\",\"matchCriteriaId\":\"B2873D5B-2501-4B02-8B68-347B69FC8D43\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2301.0\",\"versionEndExcluding\":\"2301.0003\",\"matchCriteriaId\":\"FC710071-C7AC-4ED0-9550-5FBE8FCD37AE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2306.0\",\"versionEndExcluding\":\"2306.0001\",\"matchCriteriaId\":\"8E84C2D3-EF31-46E9-884A-7EB00B515D23\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-190839.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-887122.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.bentley.com/advisories/be-2023-0004/\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\"]}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.