CVE-2023-42436 (GCVE-0-2023-42436)
Vulnerability from cvelistv5 – Published: 2023-12-26 07:22 – Updated: 2024-08-02 19:16
VLAI?
Summary
Stored cross-site scripting vulnerability exists in the presentation feature of GROWI versions prior to v3.4.0. If this vulnerability is exploited, an arbitrary script may be executed on the web browser of the user who accessed the site using the product.
Severity ?
No CVSS data available.
CWE
- Cross-site scripting (XSS)
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| WESEEK, Inc. | GROWI |
Affected:
prior to v3.4.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:16:51.003Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://weseek.co.jp/ja/news/2023/11/21/growi-prevent-xss6/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/jp/JVN18715935/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GROWI",
"vendor": "WESEEK, Inc.",
"versions": [
{
"status": "affected",
"version": "prior to v3.4.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Stored cross-site scripting vulnerability exists in the presentation feature of GROWI versions prior to v3.4.0. If this vulnerability is exploited, an arbitrary script may be executed on the web browser of the user who accessed the site using the product."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Cross-site scripting (XSS)",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-26T07:22:50.373Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://weseek.co.jp/ja/news/2023/11/21/growi-prevent-xss6/"
},
{
"url": "https://jvn.jp/en/jp/JVN18715935/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2023-42436",
"datePublished": "2023-12-26T07:22:50.373Z",
"dateReserved": "2023-12-07T02:39:45.772Z",
"dateUpdated": "2024-08-02T19:16:51.003Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:weseek:growi:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.4.0\", \"matchCriteriaId\": \"D901AB34-3DCE-4839-80CD-3FEC49A4A54D\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Stored cross-site scripting vulnerability exists in the presentation feature of GROWI versions prior to v3.4.0. If this vulnerability is exploited, an arbitrary script may be executed on the web browser of the user who accessed the site using the product.\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad de cross-site scripting almacenado en la funci\\u00f3n de presentaci\\u00f3n de las versiones de GROWI anteriores a la v3.4.0. Si se explota esta vulnerabilidad, se puede ejecutar un script arbitrario en el navegador web del usuario que accedi\\u00f3 al sitio utilizando el producto.\"}]",
"id": "CVE-2023-42436",
"lastModified": "2024-11-21T08:22:31.663",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 5.4, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 2.7}]}",
"published": "2023-12-26T08:15:09.637",
"references": "[{\"url\": \"https://jvn.jp/en/jp/JVN18715935/\", \"source\": \"vultures@jpcert.or.jp\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://weseek.co.jp/ja/news/2023/11/21/growi-prevent-xss6/\", \"source\": \"vultures@jpcert.or.jp\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://jvn.jp/en/jp/JVN18715935/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://weseek.co.jp/ja/news/2023/11/21/growi-prevent-xss6/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-42436\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2023-12-26T08:15:09.637\",\"lastModified\":\"2024-11-21T08:22:31.663\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Stored cross-site scripting vulnerability exists in the presentation feature of GROWI versions prior to v3.4.0. If this vulnerability is exploited, an arbitrary script may be executed on the web browser of the user who accessed the site using the product.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de cross-site scripting almacenado en la funci\u00f3n de presentaci\u00f3n de las versiones de GROWI anteriores a la v3.4.0. Si se explota esta vulnerabilidad, se puede ejecutar un script arbitrario en el navegador web del usuario que accedi\u00f3 al sitio utilizando el producto.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:weseek:growi:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.4.0\",\"matchCriteriaId\":\"D901AB34-3DCE-4839-80CD-3FEC49A4A54D\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/en/jp/JVN18715935/\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://weseek.co.jp/ja/news/2023/11/21/growi-prevent-xss6/\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://jvn.jp/en/jp/JVN18715935/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://weseek.co.jp/ja/news/2023/11/21/growi-prevent-xss6/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…