Action not permitted
Modal body text goes here.
CVE-2023-46283
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:45:40.675Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "lessThan": "V2407", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "lessThan": "V2312", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-08T08:40:05.349Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46283", "datePublished": "2023-12-12T11:27:14.437Z", "dateReserved": "2023-10-20T10:29:46.260Z", "dateUpdated": "2024-10-08T08:40:05.349Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-46283\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-12-12T12:15:14.067\",\"lastModified\":\"2024-10-08T09:15:09.543\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en:\\nOpcenter Quality (todas las versiones), \\nSIMATIC PCS neo (todas las versiones \u0026lt; V4.1), \\nSINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), \\nTotally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), \\nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), \\nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), \\nTotally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), \\nTotally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones \"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9D9D89CD-FDA5-42F0-8161-3752C8AED7F3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1\",\"matchCriteriaId\":\"96D49ACA-BF2E-4C89-8168-E4A95D5B22AA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\\\/automotive:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D882C3C8-EFE7-4DB6-B3E7-6152D7FEB74C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.0\",\"versionEndExcluding\":\"15\",\"matchCriteriaId\":\"29E53F22-9086-40A2-85E0-20B58EC1E4BB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"15\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"3F86DBB7-A5C7-43C4-8B64-0B67C90B79A8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndExcluding\":\"17\",\"matchCriteriaId\":\"B0BCF747-13ED-4AE7-9BE7-37858573AF27\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"17\",\"versionEndExcluding\":\"18\",\"matchCriteriaId\":\"C83587B9-53E2-4B2F-9FE4-5DDD232571F6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"085B0B91-40DE-4328-A28C-1C920A6440D1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"68C7D9A3-9304-4A81-A970-717E5BA1ECF1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*\",\"matchCriteriaId\":\"6A09C712-871D-4A81-A630-33BC5DF49FE5\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-999588.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
var-202312-0234
Vulnerability from variot
A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash. Opcenter Quality , SIMATIC PCS neo , sinumerik integrate runmyhmi /automotive A classic buffer overflow vulnerability exists in several Siemens products.Service operation interruption (DoS) It may be in a state. Opcenter Quality is a quality management system (QMS) that enables organizations to ensure compliance, optimize quality, reduce defect and rework costs, and achieve operational excellence by increasing process stability. SIMATIC PCS neo is a distributed control system (DCS). The SINUMERIK integrated product suite facilitates simple networking of machine tools in IT in production environments. User Management Component (UMC) is an integrated component that enables system-wide centralized maintenance of users
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0234", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic pcs neo", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "18" }, { "model": "opcenter quality", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinumerik integrate runmyhmi \\/automotive", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "totally integrated automation portal", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "14.0" }, { "model": "totally integrated automation portal", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "17" }, { "model": "totally integrated automation portal", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "18" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "totally integrated automation portal", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15" }, { "model": "totally integrated automation portal", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "totally integrated automation portal", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "15" }, { "model": "totally integrated automation portal", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "17" }, { "model": "totally integrated automation portal", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic pcs neo", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "opcenter quality", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "totally integrated automation portal", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinumerik integrate runmyhmi /automotive", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v16" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v17" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v14" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v15.1" }, { "model": "opcenter quality", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinumerik integrate runmyhmi /automotive", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "totally integrated automation portal update", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v18\u003cv183" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97276" }, { "db": "JVNDB", "id": "JVNDB-2023-019621" }, { "db": "NVD", "id": "CVE-2023-46283" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "16", "versionStartIncluding": "15", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "17", "versionStartIncluding": "16", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "18", "versionStartIncluding": "17", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "15", "versionStartIncluding": "14.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\/automotive:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-46283" } ] }, "cve": "CVE-2023-46283", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2023-97276", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2023-019621", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2023-46283", "trust": 1.0, "value": "HIGH" }, { "author": "OTHER", "id": "JVNDB-2023-019621", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2023-97276", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97276" }, { "db": "JVNDB", "id": "JVNDB-2023-019621" }, { "db": "NVD", "id": "CVE-2023-46283" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash. Opcenter Quality , SIMATIC PCS neo , sinumerik integrate runmyhmi /automotive A classic buffer overflow vulnerability exists in several Siemens products.Service operation interruption (DoS) It may be in a state. Opcenter Quality is a quality management system (QMS) that enables organizations to ensure compliance, optimize quality, reduce defect and rework costs, and achieve operational excellence by increasing process stability. SIMATIC PCS neo is a distributed control system (DCS). The SINUMERIK integrated product suite facilitates simple networking of machine tools in IT in production environments. User Management Component (UMC) is an integrated component that enables system-wide centralized maintenance of users", "sources": [ { "db": "NVD", "id": "CVE-2023-46283" }, { "db": "JVNDB", "id": "JVNDB-2023-019621" }, { "db": "CNVD", "id": "CNVD-2023-97276" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-46283", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-999588", "trust": 2.4 }, { "db": "JVN", "id": "JVNVU98271228", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-23-348-03", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-019621", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-97276", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97276" }, { "db": "JVNDB", "id": "JVNDB-2023-019621" }, { "db": "NVD", "id": "CVE-2023-46283" } ] }, "id": "VAR-202312-0234", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-97276" } ], "trust": 1.2076923 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97276" } ] }, "last_update_date": "2024-05-14T21:47:37.301000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens User Management Component (UMC) classic buffer overflow vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/500451" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97276" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.0 }, { "problemtype": "Classic buffer overflow (CWE-120) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019621" }, { "db": "NVD", "id": "CVE-2023-46283" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu98271228/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-46283" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-03" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97276" }, { "db": "JVNDB", "id": "JVNDB-2023-019621" }, { "db": "NVD", "id": "CVE-2023-46283" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-97276" }, { "db": "JVNDB", "id": "JVNDB-2023-019621" }, { "db": "NVD", "id": "CVE-2023-46283" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-97276" }, { "date": "2024-01-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-019621" }, { "date": "2023-12-12T12:15:14.067000", "db": "NVD", "id": "CVE-2023-46283" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-13T00:00:00", "db": "CNVD", "id": "CNVD-2023-97276" }, { "date": "2024-01-15T02:22:00", "db": "JVNDB", "id": "JVNDB-2023-019621" }, { "date": "2024-05-14T16:15:44.003000", "db": "NVD", "id": "CVE-2023-46283" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Classic buffer overflow vulnerability in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019621" } ], "trust": 0.8 } }
ssa-999588
Vulnerability from csaf_siemens
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-999588: Multiple Vulnerabilities in User Management Component (UMC) before V2.11.2 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "category": "self", "summary": "SSA-999588: Multiple Vulnerabilities in User Management Component (UMC) before V2.11.2 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-999588.json" }, { "category": "self", "summary": "SSA-999588: Multiple Vulnerabilities in User Management Component (UMC) before V2.11.2 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "category": "self", "summary": "SSA-999588: Multiple Vulnerabilities in User Management Component (UMC) before V2.11.2 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-999588.txt" } ], "title": "SSA-999588: Multiple Vulnerabilities in User Management Component (UMC) before V2.11.2", "tracking": { "current_release_date": "2024-05-14T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-999588", "initial_release_date": "2023-12-12T00:00:00Z", "revision_history": [ { "date": "2023-12-12T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2024-01-09T00:00:00Z", "legacy_version": "1.1", "number": "2", "summary": "Added fix for Totally Integrated Automation Portal (TIA Portal) V17" }, { "date": "2024-02-13T00:00:00Z", "legacy_version": "1.2", "number": "3", "summary": "Added fix for Opcenter Quality as well as product and fix for SINEC NMS" }, { "date": "2024-05-14T00:00:00Z", "legacy_version": "1.3", "number": "4", "summary": "Removed unaffected product SINUMERIK Integrate RunMyHMI /Automotive" } ], "status": "interim", "version": "4" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2312", "product": { "name": "Opcenter Quality", "product_id": "1" } } ], "category": "product_name", "name": "Opcenter Quality" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.1", "product": { "name": "SIMATIC PCS neo", "product_id": "2" } } ], "category": "product_name", "name": "SIMATIC PCS neo" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V2.0 SP1", "product": { "name": "SINEC NMS", "product_id": "3" } } ], "category": "product_name", "name": "SINEC NMS" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V14", "product_id": "4" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V14" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V15.1", "product_id": "5" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V15.1" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V16", "product_id": "6" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V16" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V17 Update 7", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V17", "product_id": "7" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V17" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V18 Update 3", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V18", "product_id": "8" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V18" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-46281", "cwe": { "id": "CWE-942", "name": "Permissive Cross-domain Policy with Untrusted Domains" }, "notes": [ { "category": "summary", "text": "When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "4", "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "6" ] }, { "category": "vendor_fix", "details": "Update to V17 Update 7 or later version", "product_ids": [ "7" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 3 or later version", "product_ids": [ "8" ] }, { "category": "vendor_fix", "details": "Update to V2.0 SP1 or later version", "product_ids": [ "3" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826954/" }, { "category": "vendor_fix", "details": "Update to V2312 or later version", "product_ids": [ "1" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V4.1 or later version", "product_ids": [ "2" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825230/" }, { "category": "workaround", "details": "CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "title": "CVE-2023-46281" }, { "cve": "CVE-2023-46282", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "4", "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "6" ] }, { "category": "vendor_fix", "details": "Update to V17 Update 7 or later version", "product_ids": [ "7" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 3 or later version", "product_ids": [ "8" ] }, { "category": "vendor_fix", "details": "Update to V2.0 SP1 or later version", "product_ids": [ "3" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826954/" }, { "category": "vendor_fix", "details": "Update to V2312 or later version", "product_ids": [ "1" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V4.1 or later version", "product_ids": [ "2" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825230/" }, { "category": "workaround", "details": "CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "title": "CVE-2023-46282" }, { "cve": "CVE-2023-46283", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "4", "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "6" ] }, { "category": "vendor_fix", "details": "Update to V17 Update 7 or later version", "product_ids": [ "7" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 3 or later version", "product_ids": [ "8" ] }, { "category": "vendor_fix", "details": "Update to V2.0 SP1 or later version", "product_ids": [ "3" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826954/" }, { "category": "vendor_fix", "details": "Update to V2312 or later version", "product_ids": [ "1" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V4.1 or later version", "product_ids": [ "2" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825230/" }, { "category": "workaround", "details": "CVE-2023-46283, CVE-2023-46284: If only one UMC server is used, block access to port 4002/tcp e.g. with an external firewall", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "title": "CVE-2023-46283" }, { "cve": "CVE-2023-46284", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "4", "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "6" ] }, { "category": "vendor_fix", "details": "Update to V17 Update 7 or later version", "product_ids": [ "7" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 3 or later version", "product_ids": [ "8" ] }, { "category": "vendor_fix", "details": "Update to V2.0 SP1 or later version", "product_ids": [ "3" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826954/" }, { "category": "vendor_fix", "details": "Update to V2312 or later version", "product_ids": [ "1" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V4.1 or later version", "product_ids": [ "2" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825230/" }, { "category": "workaround", "details": "CVE-2023-46283, CVE-2023-46284: If only one UMC server is used, block access to port 4002/tcp e.g. with an external firewall", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8" ] }, { "category": "workaround", "details": "CVE-2023-46284, CVE-2023-46285: If only one RT server is used, block access to port 4004/tcp e.g. with an external firewall. If the deployment contains no RT-Servers, block the port in the local firewall.", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "title": "CVE-2023-46284" }, { "cve": "CVE-2023-46285", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "4", "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "6" ] }, { "category": "vendor_fix", "details": "Update to V17 Update 7 or later version", "product_ids": [ "7" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 3 or later version", "product_ids": [ "8" ] }, { "category": "vendor_fix", "details": "Update to V2.0 SP1 or later version", "product_ids": [ "3" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826954/" }, { "category": "vendor_fix", "details": "Update to V2312 or later version", "product_ids": [ "1" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V4.1 or later version", "product_ids": [ "2" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825230/" }, { "category": "workaround", "details": "CVE-2023-46284, CVE-2023-46285: If only one RT server is used, block access to port 4004/tcp e.g. with an external firewall. If the deployment contains no RT-Servers, block the port in the local firewall.", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "title": "CVE-2023-46285" } ] }
wid-sec-w-2023-3100
Vulnerability from csaf_certbund
Notes
{ "document": { "aggregate_severity": { "text": "mittel" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "TIA-Portal ist ein Automatisierungsframework f\u00fcr Steuerungen und andere Automatisierungsger\u00e4te der SIMATIC-Serie.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein Angreifer kann mehrere Schwachstellen in Siemens TIA Portal ausnutzen, um ein unerw\u00fcnschtes Verhalten auszul\u00f6sen, einen Cross Site Scripting Angriff durchzuf\u00fchren oder einen Denial of Service zu verursachen.", "title": "Angriff" }, { "category": "general", "text": "- Windows", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2023-3100 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2023/wid-sec-w-2023-3100.json" }, { "category": "self", "summary": "WID-SEC-2023-3100 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2023-3100" }, { "category": "external", "summary": "Siemens Security Advisory by Siemens ProductCERT vom 2023-12-11", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ], "source_lang": "en-US", "title": "Siemens TIA Portal: Mehrere Schwachstellen", "tracking": { "current_release_date": "2023-12-11T23:00:00.000+00:00", "generator": { "date": "2024-02-15T17:53:41.906+00:00", "engine": { "name": "BSI-WID", "version": "1.3.0" } }, "id": "WID-SEC-W-2023-3100", "initial_release_date": "2023-12-11T23:00:00.000+00:00", "revision_history": [ { "date": "2023-12-11T23:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_name", "name": "Siemens TIA Portal V16", "product": { "name": "Siemens TIA Portal V16", "product_id": "T027140", "product_identification_helper": { "cpe": "cpe:/a:siemens:tia_portal:v16" } } }, { "category": "product_name", "name": "Siemens TIA Portal V17", "product": { "name": "Siemens TIA Portal V17", "product_id": "T027141", "product_identification_helper": { "cpe": "cpe:/a:siemens:tia_portal:v17" } } }, { "category": "product_name", "name": "Siemens TIA Portal V14", "product": { "name": "Siemens TIA Portal V14", "product_id": "T031591", "product_identification_helper": { "cpe": "cpe:/a:siemens:tia_portal:v14" } } }, { "category": "product_name", "name": "Siemens TIA Portal V15.1", "product": { "name": "Siemens TIA Portal V15.1", "product_id": "T031592", "product_identification_helper": { "cpe": "cpe:/a:siemens:tia_portal:v15.1" } } }, { "category": "product_name", "name": "Siemens TIA Portal \u003c V18 update 3", "product": { "name": "Siemens TIA Portal \u003c V18 update 3", "product_id": "T031593", "product_identification_helper": { "cpe": "cpe:/a:siemens:tia_portal:v18_update_3" } } } ], "category": "product_name", "name": "TIA Portal" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-46281", "notes": [ { "category": "description", "text": "Es existiert eine Schwachstelle in Siemens TIA Portal. Beim Zugriff auf die UMC Web-UI von betroffenen Produkten aus verwendet UMC eine \u00fcberm\u00e4\u00dfig freiz\u00fcgige CORS-Richtlinie. Ein Angreifer kann diese Schwachstelle ausnutzen, um ein unerw\u00fcnschtes Verhalten auszul\u00f6sen." } ], "product_status": { "known_affected": [ "T027140", "T027141", "T031591", "T031592" ] }, "release_date": "2023-12-11T23:00:00Z", "title": "CVE-2023-46281" }, { "cve": "CVE-2023-46282", "notes": [ { "category": "description", "text": "In Siemens TIA Portal existiert eine Cross-Site Scripting Schwachstelle. HTML und Script-Eingaben werden im Web Interface nicht ordnungsgem\u00e4\u00df \u00fcberpr\u00fcft, bevor sie an den Benutzer zur\u00fcckgegeben werden. Ein entfernter, anonymer Angreifer kann durch Ausnutzung dieser Schwachstelle beliebigen HTML- und Script-Code durch den Browser des Benutzers im Kontext der betroffenen Seite ausf\u00fchren. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich." } ], "product_status": { "known_affected": [ "T027140", "T027141", "T031591", "T031592" ] }, "release_date": "2023-12-11T23:00:00Z", "title": "CVE-2023-46282" }, { "cve": "CVE-2023-46285", "notes": [ { "category": "description", "text": "In Siemens TIA Portal existieren mehrere Schwachstellen. Mehrere Out of Bounds write Probleme und eine ungen\u00fcgende Eingabe\u00fcberpr\u00fcfung k\u00f6nnen zum Absturz der Applikation f\u00fchren. Ein entfernter, anonymer Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T027140", "T027141", "T031591", "T031592" ] }, "release_date": "2023-12-11T23:00:00Z", "title": "CVE-2023-46285" }, { "cve": "CVE-2023-46284", "notes": [ { "category": "description", "text": "In Siemens TIA Portal existieren mehrere Schwachstellen. Mehrere Out of Bounds write Probleme und eine ungen\u00fcgende Eingabe\u00fcberpr\u00fcfung k\u00f6nnen zum Absturz der Applikation f\u00fchren. Ein entfernter, anonymer Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T027140", "T027141", "T031591", "T031592" ] }, "release_date": "2023-12-11T23:00:00Z", "title": "CVE-2023-46284" }, { "cve": "CVE-2023-46283", "notes": [ { "category": "description", "text": "In Siemens TIA Portal existieren mehrere Schwachstellen. Mehrere Out of Bounds write Probleme und eine ungen\u00fcgende Eingabe\u00fcberpr\u00fcfung k\u00f6nnen zum Absturz der Applikation f\u00fchren. Ein entfernter, anonymer Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T027140", "T027141", "T031591", "T031592" ] }, "release_date": "2023-12-11T23:00:00Z", "title": "CVE-2023-46283" } ] }
icsa-23-348-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server.\n\nSiemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products where updates are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-999588: Multiple Vulnerabilities in User Management Component (UMC) before V2.11.2 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-999588.json" }, { "category": "self", "summary": "SSA-999588: Multiple Vulnerabilities in User Management Component (UMC) before V2.11.2 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "category": "self", "summary": "SSA-999588: Multiple Vulnerabilities in User Management Component (UMC) before V2.11.2 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "category": "self", "summary": "SSA-999588: Multiple Vulnerabilities in User Management Component (UMC) before V2.11.2 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-999588.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-348-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-348-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-348-03 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens User Management Component (UMC)", "tracking": { "current_release_date": "2023-12-12T00:00:00Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-23-348-03", "initial_release_date": "2023-12-12T00:00:00Z", "revision_history": [ { "date": "2023-12-12T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Opcenter Quality", "product_id": "1" } } ], "category": "product_name", "name": "Opcenter Quality" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.1", "product": { "name": "SIMATIC PCS neo", "product_id": "2" } } ], "category": "product_name", "name": "SIMATIC PCS neo" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SINUMERIK Integrate RunMyHMI\u00a0/Automotive", "product_id": "3" } } ], "category": "product_name", "name": "SINUMERIK Integrate RunMyHMI\u00a0/Automotive" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V14", "product_id": "4" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V14" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V15.1", "product_id": "5" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V15.1" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V16", "product_id": "6" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V16" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V17", "product_id": "7" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V17" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V18 Update 3", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V18", "product_id": "8" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V18" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-46281", "cwe": { "id": "CWE-942", "name": "Permissive Cross-domain Policy with Untrusted Domains" }, "notes": [ { "category": "summary", "text": "When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "4", "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1", "3", "6", "7" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 3 or later version", "product_ids": [ "8" ] }, { "category": "vendor_fix", "details": "Update to V4.1 or later version", "product_ids": [ "2" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825230/" }, { "category": "workaround", "details": "CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "title": "CVE-2023-46281" }, { "cve": "CVE-2023-46282", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "4", "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1", "3", "6", "7" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 3 or later version", "product_ids": [ "8" ] }, { "category": "vendor_fix", "details": "Update to V4.1 or later version", "product_ids": [ "2" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825230/" }, { "category": "workaround", "details": "CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "title": "CVE-2023-46282" }, { "cve": "CVE-2023-46283", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "4", "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1", "3", "6", "7" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 3 or later version", "product_ids": [ "8" ] }, { "category": "vendor_fix", "details": "Update to V4.1 or later version", "product_ids": [ "2" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825230/" }, { "category": "workaround", "details": "CVE-2023-46283, CVE-2023-46284: If only one UMC server is used, block access to port 4002/tcp e.g. with an external firewall", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "title": "CVE-2023-46283" }, { "cve": "CVE-2023-46284", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "4", "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1", "3", "6", "7" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 3 or later version", "product_ids": [ "8" ] }, { "category": "vendor_fix", "details": "Update to V4.1 or later version", "product_ids": [ "2" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825230/" }, { "category": "workaround", "details": "CVE-2023-46283, CVE-2023-46284: If only one UMC server is used, block access to port 4002/tcp e.g. with an external firewall", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8" ] }, { "category": "workaround", "details": "CVE-2023-46284, CVE-2023-46285: If only one RT server is used, block access to port 4004/tcp e.g. with an external firewall. If the deployment contains no RT-Servers, block the port in the local firewall.", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "title": "CVE-2023-46284" }, { "cve": "CVE-2023-46285", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "4", "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1", "3", "6", "7" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 3 or later version", "product_ids": [ "8" ] }, { "category": "vendor_fix", "details": "Update to V4.1 or later version", "product_ids": [ "2" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825230/" }, { "category": "workaround", "details": "CVE-2023-46284, CVE-2023-46285: If only one RT server is used, block access to port 4004/tcp e.g. with an external firewall. If the deployment contains no RT-Servers, block the port in the local firewall.", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "title": "CVE-2023-46285" } ] }
ghsa-395m-pvc6-8rvm
Vulnerability from github
A vulnerability has been identified in Opcenter Quality (All versions), SIMATIC PCS neo (All versions < V4.1), SINUMERIK Integrate RunMyHMI /Automotive (All versions), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
{ "affected": [], "aliases": [ "CVE-2023-46283" ], "database_specific": { "cwe_ids": [ "CWE-120" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2023-12-12T12:15:14Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in Opcenter Quality (All versions), SIMATIC PCS neo (All versions \u003c V4.1), SINUMERIK Integrate RunMyHMI\u00a0/Automotive (All versions), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.", "id": "GHSA-395m-pvc6-8rvm", "modified": "2024-10-08T09:30:51Z", "published": "2023-12-12T12:30:54Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-46283" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "type": "CVSS_V3" } ] }
gsd-2023-46283
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2023-46283", "id": "GSD-2023-46283" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-46283" ], "details": "A vulnerability has been identified in Opcenter Quality (All versions), SIMATIC PCS neo (All versions \u003c V4.1), SINUMERIK Integrate RunMyHMI\u00a0/Automotive (All versions), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.", "id": "GSD-2023-46283", "modified": "2023-12-13T01:20:53.293874Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2023-46283", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Opcenter Quality", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V2312" } ] } }, { "product_name": "SIMATIC PCS neo", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V4.1" } ] } }, { "product_name": "SINEC NMS", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V2.0 SP1" } ] } }, { "product_name": "SINUMERIK Integrate RunMyHMI\u00a0/Automotive", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions" } ] } }, { "product_name": "Totally Integrated Automation Portal (TIA Portal) V14", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "*" } ] } }, { "product_name": "Totally Integrated Automation Portal (TIA Portal) V15.1", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "*" } ] } }, { "product_name": "Totally Integrated Automation Portal (TIA Portal) V16", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "*" } ] } }, { "product_name": "Totally Integrated Automation Portal (TIA Portal) V17", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V17 Update 7" } ] } }, { "product_name": "Totally Integrated Automation Portal (TIA Portal) V18", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V18 Update 3" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), SINUMERIK Integrate RunMyHMI\u00a0/Automotive (All versions), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash." } ] }, "impact": { "cvss": [ { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-120", "lang": "eng", "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ] } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", "versionEndExcluding": "4.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\/automotive:-:*:*:*:*:*:*:*", "matchCriteriaId": "D882C3C8-EFE7-4DB6-B3E7-6152D7FEB74C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "29E53F22-9086-40A2-85E0-20B58EC1E4BB", "versionEndExcluding": "15", "versionStartIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F86DBB7-A5C7-43C4-8B64-0B67C90B79A8", "versionEndExcluding": "16", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0BCF747-13ED-4AE7-9BE7-37858573AF27", "versionEndExcluding": "17", "versionStartIncluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "C83587B9-53E2-4B2F-9FE4-5DDD232571F6", "versionEndExcluding": "18", "versionStartIncluding": "17", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*", "matchCriteriaId": "085B0B91-40DE-4328-A28C-1C920A6440D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*", "matchCriteriaId": "68C7D9A3-9304-4A81-A970-717E5BA1ECF1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*", "matchCriteriaId": "6A09C712-871D-4A81-A630-33BC5DF49FE5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), SINUMERIK Integrate RunMyHMI\u00a0/Automotive (All versions), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en:\nOpcenter Quality (todas las versiones), \nSIMATIC PCS neo (todas las versiones \u0026lt; V4.1), \nSINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones " } ], "id": "CVE-2023-46283", "lastModified": "2024-02-13T09:15:45.443", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Primary" } ] }, "published": "2023-12-12T12:15:14.067", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "productcert@siemens.com", "type": "Primary" } ] } } } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.