CVE-2023-46664
Vulnerability from cvelistv5
Published
2023-10-26 20:04
Modified
2024-08-02 20:53
Summary
Improper Access Control in Sielco PolyEco1000
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/news-events/ics-advisories/icsa-23-299-07Third Party Advisory, US Government Resource
Impacted products
Sielco PolyEco1000
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T20:53:20.676Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-299-07"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PolyEco1000",
          "vendor": "Sielco ",
          "versions": [
            {
              "status": "affected",
              "version": "CPU:2.0.6 FPGA:10.19"
            },
            {
              "status": "affected",
              "version": "CPU:1.9.4 FPGA:10.19"
            },
            {
              "status": "affected",
              "version": "CPU:1.9.3 FPGA:10.19"
            },
            {
              "status": "affected",
              "version": "CPU:1.7.0 FPGA:10.16"
            },
            {
              "status": "affected",
              "version": "CPU:2.0.2 FPGA:10.19"
            },
            {
              "status": "affected",
              "version": "CPU:2.0.0 FPGA:10.19"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Gjoko Krstic"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\n\n\u003c/p\u003e\u003cp\u003eSielco PolyEco1000 is vulnerable to an improper access control vulnerability when the application provides direct access to objects based on user-supplied input. As a result of this vulnerability attackers can bypass authorization and access resources behind protected pages.\u003c/p\u003e\n\n\u003cp\u003e\u003c/p\u003e\n\n"
            }
          ],
          "value": "\n\n\n\n\n\n\n\n\n\n\n\n\nSielco PolyEco1000 is vulnerable to an improper access control vulnerability when the application provides direct access to objects based on user-supplied input. As a result of this vulnerability attackers can bypass authorization and access resources behind protected pages.\n\n\n\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-26T20:04:33.638Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-299-07"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper Access Control in Sielco PolyEco1000",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-46664",
    "datePublished": "2023-10-26T20:04:33.638Z",
    "dateReserved": "2023-10-24T16:27:17.282Z",
    "dateUpdated": "2024-08-02T20:53:20.676Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-46664\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2023-10-26T21:15:07.967\",\"lastModified\":\"2023-11-07T15:55:17.837\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\nSielco PolyEco1000 is vulnerable to an improper access control vulnerability when the application provides direct access to objects based on user-supplied input. As a result of this vulnerability attackers can bypass authorization and access resources behind protected pages.\\n\\n\\n\\n\\n\\n\\n\\n\"},{\"lang\":\"es\",\"value\":\"Sielco PolyEco1000 es afectada por una vulnerabilidad de control de acceso inadecuado cuando la aplicaci\u00f3n proporciona acceso directo a objetos bas\u00e1ndose en la entrada proporcionada por el usuario. Como resultado de esta vulnerabilidad, los atacantes pueden eludir la autorizaci\u00f3n y acceder a recursos detr\u00e1s de p\u00e1ginas protegidas.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2},{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]},{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sielco:polyeco500_firmware:1.7.0:*:*:*:cpu:*:*:*\",\"matchCriteriaId\":\"E64F96A4-542A-486E-AC9A-3EC1E68A6D1E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sielco:polyeco500_firmware:10.16:*:*:*:fpga:*:*:*\",\"matchCriteriaId\":\"E3A4049B-D0B2-4CB6-8B31-ECD3BF4FF384\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:sielco:polyeco500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D7E931F0-5608-4F24-821B-3DB29972C077\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sielco:polyeco300_firmware:2.0.0:*:*:*:cpu:*:*:*\",\"matchCriteriaId\":\"BBA5260D-A7D3-4973-8106-E8C73F50A6CE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sielco:polyeco300_firmware:2.0.2:*:*:*:cpu:*:*:*\",\"matchCriteriaId\":\"F7CE9236-A970-49F0-A200-84BC3B77CECB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sielco:polyeco300_firmware:10.19:*:*:*:fpga:*:*:*\",\"matchCriteriaId\":\"D45CE1CD-FB47-4FFD-974E-B55B569A5850\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:sielco:polyeco300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"05832105-6C9E-4850-A145-F3E241058CCA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sielco:polyeco1000_firmware:1.9.3:*:*:*:cpu:*:*:*\",\"matchCriteriaId\":\"991B1AD8-671D-4EF9-901B-0834748258F5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sielco:polyeco1000_firmware:1.9.4:*:*:*:cpu:*:*:*\",\"matchCriteriaId\":\"FE961B31-1553-4457-8436-8F9662AA10CA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sielco:polyeco1000_firmware:2.0.6:*:*:*:cpu:*:*:*\",\"matchCriteriaId\":\"0BF0380D-483C-4B14-BF42-AC1E9C79D2DE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sielco:polyeco1000_firmware:10.19:*:*:*:fpga:*:*:*\",\"matchCriteriaId\":\"F0E5773E-8842-4FCB-80BD-266A237042E7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:sielco:polyeco1000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"01DB9D87-6F35-4171-AD59-9B90386F431E\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-23-299-07\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.