CVE-2023-51363
Vulnerability from cvelistv5
Published
2023-12-26 07:30
Modified
2024-08-02 22:32
Severity ?
Summary
VR-S1000 firmware Ver. 2.37 and earlier allows a network-adjacent unauthenticated attacker who can access the product's web management page to obtain sensitive information.
Impacted products
BUFFALO INC.VR-S1000
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:32:09.188Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/jp/JVN23771490/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VR-S1000",
          "vendor": "BUFFALO INC.",
          "versions": [
            {
              "status": "affected",
              "version": "firmware Ver. 2.37 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "VR-S1000 firmware Ver. 2.37 and earlier allows a network-adjacent unauthenticated attacker who can access the product\u0027s web management page to obtain sensitive information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Information disclosure",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-12-26T07:30:12.168Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
        },
        {
          "url": "https://jvn.jp/en/jp/JVN23771490/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2023-51363",
    "datePublished": "2023-12-26T07:30:12.168Z",
    "dateReserved": "2023-12-18T12:18:02.891Z",
    "dateUpdated": "2024-08-02T22:32:09.188Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-51363\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2023-12-26T08:15:11.760\",\"lastModified\":\"2024-02-20T18:52:19.997\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"VR-S1000 firmware Ver. 2.37 and earlier allows a network-adjacent unauthenticated attacker who can access the product\u0027s web management page to obtain sensitive information.\"},{\"lang\":\"es\",\"value\":\"Versi\u00f3n del firmware VR-S1000. 2.37 y anteriores permiten que un atacante no autenticado adyacente a la red pueda acceder a la p\u00e1gina de administraci\u00f3n web del producto para obtener informaci\u00f3n confidencial.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:buffalo:vr-s1000_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.37\",\"matchCriteriaId\":\"C961815C-579A-4422-8C61-467B547E0D23\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:buffalo:vr-s1000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"45640129-5499-47CD-A890-A86F4B79B6C8\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/en/jp/JVN23771490/\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.buffalo.jp/news/detail/20231225-01.html\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.