CVE-2023-6314
Vulnerability from cvelistv5
Published
2023-12-19 00:24
Modified
2024-08-27 19:01
Summary
Stack-based buffer overflow in FPWin Pro version 7.7.0.0 and all previous versions may allow attackers to execute arbitrary code via a specially crafted project file.
Impacted products
PanasonicControl FPWIN Pro
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:28:21.055Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://industry.panasonic.eu/products/automation-devices-solutions/programmable-logic-controllers-plc/plc-software/programming-software-control-fpwin-pro"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-6314",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-27T19:00:42.507828Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-27T19:01:32.558Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Control FPWIN Pro",
          "vendor": "Panasonic",
          "versions": [
            {
              "lessThanOrEqual": "7.7.0.0",
              "status": "affected",
              "version": "n/a",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Stack-based buffer overflow in FPWin Pro version 7.7.0.0 and all previous versions may allow attackers to execute arbitrary code via a specially crafted project file."
            }
          ],
          "value": "Stack-based buffer overflow in FPWin Pro version 7.7.0.0 and all previous versions may allow attackers to execute arbitrary code via a specially crafted project file."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-12-19T00:24:37.946Z",
        "orgId": "2163caeb-3942-4e93-a74b-8c75338146ce",
        "shortName": "Panasonic_Holdings_Corporation"
      },
      "references": [
        {
          "url": "https://industry.panasonic.eu/products/automation-devices-solutions/programmable-logic-controllers-plc/plc-software/programming-software-control-fpwin-pro"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2163caeb-3942-4e93-a74b-8c75338146ce",
    "assignerShortName": "Panasonic_Holdings_Corporation",
    "cveId": "CVE-2023-6314",
    "datePublished": "2023-12-19T00:24:37.946Z",
    "dateReserved": "2023-11-27T05:48:34.594Z",
    "dateUpdated": "2024-08-27T19:01:32.558Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-6314\",\"sourceIdentifier\":\"product-security@gg.jp.panasonic.com\",\"published\":\"2023-12-19T01:15:12.157\",\"lastModified\":\"2024-01-02T13:31:21.217\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Stack-based buffer overflow in FPWin Pro version 7.7.0.0 and all previous versions may allow attackers to execute arbitrary code via a specially crafted project file.\"},{\"lang\":\"es\",\"value\":\"El desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria en FPWin Pro versi\u00f3n 7.7.0.0 y todas las versiones anteriores puede permitir a los atacantes ejecutar c\u00f3digo arbitrario a trav\u00e9s de un archivo de proyecto especialmente manipulado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"product-security@gg.jp.panasonic.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:panasonic:fpwin_pro:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.7.0.0\",\"matchCriteriaId\":\"3F6A3061-FE7B-4973-965B-632CFFC1FCC8\"}]}]}],\"references\":[{\"url\":\"https://industry.panasonic.eu/products/automation-devices-solutions/programmable-logic-controllers-plc/plc-software/programming-software-control-fpwin-pro\",\"source\":\"product-security@gg.jp.panasonic.com\",\"tags\":[\"Product\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.