CVE-2024-11013
Vulnerability from cvelistv5
Published
2024-11-29 08:03
Modified
2024-11-29 13:40
Summary
Command Injection vulnerability in NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21, for Ver10.8 up to Ver10.8.27, for Ver10.9 up to Ver10.9.14 and UNIVERGE IX-R/IX-V Ver1.2.15 and earlier allows a attacker to inject an arbitrary CLI commands to be executed on the device via the management interface.
Impacted products
Vendor Product Version
NEC Corporation UNIVERGE IX Version: for Ver10.8 up to Ver10.8.27
NEC Corporation UNIVERGE IX Version: for Ver10.9 up to Ver10.9.14
NEC Corporation UNIVERGE IX-R/IX-V Version: Ver1.2.15 and earlier
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:nec_corporation:univerge_1x:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "univerge_1x",
            "vendor": "nec_corporation",
            "versions": [
              {
                "lessThanOrEqual": "10.10.21",
                "status": "affected",
                "version": "9.2",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "10.8.27",
                "status": "affected",
                "version": "10.8",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "10.9.14",
                "status": "affected",
                "version": "10.9",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:nec_corporation:univerge_1x-r\\/ix-v:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "univerge_1x-r\\/ix-v",
            "vendor": "nec_corporation",
            "versions": [
              {
                "lessThan": "1.2.15",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11013",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-29T13:34:19.048337Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-29T13:40:11.027Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "UNIVERGE IX",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "from Ver9.2 to Ver10.10.21"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UNIVERGE IX",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "for Ver10.8 up to Ver10.8.27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UNIVERGE IX",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "for Ver10.9 up to Ver10.9.14"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UNIVERGE IX-R/IX-V",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Ver1.2.15 and earlier"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "RyotaK of Flatt Security Inc."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Command Injection vulnerability in NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21, for Ver10.8 up to Ver10.8.27, for Ver10.9 up to Ver10.9.14 and UNIVERGE IX-R/IX-V Ver1.2.15 and earlier allows a attacker to inject an arbitrary CLI commands to be executed on the device via the management interface."
            }
          ],
          "value": "Command Injection vulnerability in NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21, for Ver10.8 up to Ver10.8.27, for Ver10.9 up to Ver10.9.14 and UNIVERGE IX-R/IX-V Ver1.2.15 and earlier allows a attacker to inject an arbitrary CLI commands to be executed on the device via the management interface."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-29T08:03:07.458Z",
        "orgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
        "shortName": "NEC"
      },
      "references": [
        {
          "url": "https://https://jpn.nec.com/security-info/secinfo/nv24-009_en.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
    "assignerShortName": "NEC",
    "cveId": "CVE-2024-11013",
    "datePublished": "2024-11-29T08:03:07.458Z",
    "dateReserved": "2024-11-08T02:59:55.534Z",
    "dateUpdated": "2024-11-29T13:40:11.027Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-11013\",\"sourceIdentifier\":\"psirt-info@cyber.jp.nec.com\",\"published\":\"2024-11-29T08:15:03.923\",\"lastModified\":\"2024-11-29T08:15:03.923\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Command Injection vulnerability in NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21, for Ver10.8 up to Ver10.8.27, for Ver10.9 up to Ver10.9.14 and UNIVERGE IX-R/IX-V Ver1.2.15 and earlier allows a attacker to inject an arbitrary CLI commands to be executed on the device via the management interface.\"},{\"lang\":\"es\",\"value\":\"La vulnerabilidad de inyecci\u00f3n de comandos en NEC Corporation UNIVERGE IX desde Ver9.2 hasta Ver10.10.21, desde Ver10.8 hasta Ver10.8.27, desde Ver10.9 hasta Ver10.9.14 y UNIVERGE IX-R/IX-V Ver1.2.15 y anteriores permite a un atacante inyectar comandos CLI arbitrarios para que se ejecuten en el dispositivo a trav\u00e9s de la interfaz de administraci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt-info@cyber.jp.nec.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"psirt-info@cyber.jp.nec.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"references\":[{\"url\":\"https://https://jpn.nec.com/security-info/secinfo/nv24-009_en.html\",\"source\":\"psirt-info@cyber.jp.nec.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.