CVE-2024-12833 (GCVE-0-2024-12833)

Vulnerability from cvelistv5 – Published: 2025-02-11 19:23 – Updated: 2025-02-12 19:11
VLAI?
Summary
Paessler PRTG Network Monitor SNMP Cross-Site Scripting Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Paessler PRTG Network Monitor. Some user interaction on the part of an administrator is required to exploit this vulnerability. The specific flaw exists within the PRTG Network Monitor web interface. The issue results from the lack of proper validation of user-supplied data, which can lead to the injection of an arbitrary script. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-23371.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
zdi
References
Impacted products
Vendor Product Version
Paessler PRTG Network Monitor Affected: 24.1.92.1554 x64
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-12833",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-11T19:54:24.218569Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-12T19:11:13.548Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "PRTG Network Monitor",
          "vendor": "Paessler",
          "versions": [
            {
              "status": "affected",
              "version": "24.1.92.1554 x64"
            }
          ]
        }
      ],
      "dateAssigned": "2024-12-19T22:20:57.954Z",
      "datePublic": "2025-01-20T02:52:23.415Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Paessler PRTG Network Monitor SNMP Cross-Site Scripting Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Paessler PRTG Network Monitor. Some user interaction on the part of an administrator is required to exploit this vulnerability.\n\nThe specific flaw exists within the PRTG Network Monitor web interface. The issue results from the lack of proper validation of user-supplied data, which can lead to the injection of an arbitrary script. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-23371."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-11T19:23:53.715Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1736",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1736/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "Andreas Finstad"
      },
      "title": "Paessler PRTG Network Monitor SNMP Cross-Site Scripting Authentication Bypass Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-12833",
    "datePublished": "2025-02-11T19:23:53.715Z",
    "dateReserved": "2024-12-19T22:20:57.912Z",
    "dateUpdated": "2025-02-12T19:11:13.548Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-12833\",\"sourceIdentifier\":\"zdi-disclosures@trendmicro.com\",\"published\":\"2025-02-11T20:15:34.077\",\"lastModified\":\"2025-02-18T21:39:31.887\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Paessler PRTG Network Monitor SNMP Cross-Site Scripting Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Paessler PRTG Network Monitor. Some user interaction on the part of an administrator is required to exploit this vulnerability.\\n\\nThe specific flaw exists within the PRTG Network Monitor web interface. The issue results from the lack of proper validation of user-supplied data, which can lead to the injection of an arbitrary script. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-23371.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n mediante Cross-Site Scripting SNMP en Paessler PRTG Network Monitor. Esta vulnerabilidad permite a los atacantes adyacentes a la red omitir la autenticaci\u00f3n en las instalaciones afectadas de Paessler PRTG Network Monitor. Se requiere cierta interacci\u00f3n del usuario por parte de un administrador para explotar esta vulnerabilidad. La falla espec\u00edfica existe dentro de la interfaz web de PRTG Network Monitor. El problema es el resultado de la falta de una validaci\u00f3n adecuada de los datos proporcionados por el usuario, lo que puede llevar a la inyecci\u00f3n de una secuencia de comandos arbitraria. Un atacante puede aprovechar esta vulnerabilidad para omitir la autenticaci\u00f3n en el sistema. Era ZDI-CAN-23371.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV30\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":8.0,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.1,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:paessler:prtg_network_monitor:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"25.1.102.1373\",\"matchCriteriaId\":\"0955FE55-AD08-4BEF-829E-A1FC9ADAACBB\"}]}]}],\"references\":[{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-24-1736/\",\"source\":\"zdi-disclosures@trendmicro.com\",\"tags\":[\"Third Party Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-12833\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-11T19:54:24.218569Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-12T19:10:13.819Z\"}}], \"cna\": {\"title\": \"Paessler PRTG Network Monitor SNMP Cross-Site Scripting Authentication Bypass Vulnerability\", \"source\": {\"lang\": \"en\", \"value\": \"Andreas Finstad\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\"}}], \"affected\": [{\"vendor\": \"Paessler\", \"product\": \"PRTG Network Monitor\", \"versions\": [{\"status\": \"affected\", \"version\": \"24.1.92.1554 x64\"}], \"defaultStatus\": \"unknown\"}], \"datePublic\": \"2025-01-20T02:52:23.415Z\", \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-24-1736/\", \"name\": \"ZDI-24-1736\", \"tags\": [\"x_research-advisory\"]}], \"dateAssigned\": \"2024-12-19T22:20:57.954Z\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"Paessler PRTG Network Monitor SNMP Cross-Site Scripting Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Paessler PRTG Network Monitor. Some user interaction on the part of an administrator is required to exploit this vulnerability.\\n\\nThe specific flaw exists within the PRTG Network Monitor web interface. The issue results from the lack of proper validation of user-supplied data, which can lead to the injection of an arbitrary script. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-23371.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"shortName\": \"zdi\", \"dateUpdated\": \"2025-02-11T19:23:53.715Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-12833\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-12T19:11:13.548Z\", \"dateReserved\": \"2024-12-19T22:20:57.912Z\", \"assignerOrgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"datePublished\": \"2025-02-11T19:23:53.715Z\", \"assignerShortName\": \"zdi\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…