CVE-2024-1367 (GCVE-0-2024-1367)
Vulnerability from cvelistv5 – Published: 2024-02-14 21:35 – Updated: 2025-05-02 16:26
VLAI?
Summary
A command injection vulnerability exists where an authenticated, remote attacker with administrator privileges on the Security Center application could modify Logging parameters, which could lead to the execution of arbitrary code on the Security Center host.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Tenable | Security Center |
Affected:
0 , < 6.3.0
(6.3.0)
|
Credits
Paweł Bednarz
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:40:19.949Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.tenable.com/security/tns-2024-02"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-1367",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-15T20:05:10.392514Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-02T16:26:07.235Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"platforms": [
"Linux"
],
"product": "Security Center",
"vendor": "Tenable",
"versions": [
{
"lessThan": "6.3.0",
"status": "affected",
"version": "0",
"versionType": "6.3.0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Pawe\u0142 Bednarz"
}
],
"datePublic": "2024-02-14T19:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA command injection vulnerability exists where an authenticated, remote attacker with administrator privileges on the Security Center application could modify Logging parameters, which could lead to the execution of arbitrary code on the Security Center host. \n\n"
}
],
"value": "\nA command injection vulnerability exists where an authenticated, remote attacker with administrator privileges on the Security Center application could modify Logging parameters, which could lead to the execution of arbitrary code on the Security Center host. \n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-248",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-248 Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-14T21:35:16.767Z",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"url": "https://www.tenable.com/security/tns-2024-02"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eTenable has released Security Center 6.3.0 to address these issues. The installation files can be obtained from the Tenable Downloads Portal: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tenable.com/downloads/security-center\"\u003ehttps://www.tenable.com/downloads/security-center\u003c/a\u003e\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "\nTenable has released Security Center 6.3.0 to address these issues. The installation files can be obtained from the Tenable Downloads Portal: https://www.tenable.com/downloads/security-center https://www.tenable.com/downloads/security-center \n\n\n\n\n\n"
}
],
"source": {
"advisory": "TNS-2024-02",
"discovery": "EXTERNAL"
},
"title": "Command Injection Vulnerability in Tenable Security Center",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2024-1367",
"datePublished": "2024-02-14T21:35:16.767Z",
"dateReserved": "2024-02-08T19:43:20.585Z",
"dateUpdated": "2025-05-02T16:26:07.235Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:tenable:security_center:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.3.0\", \"matchCriteriaId\": \"E4F24FE6-9C35-4B06-99E7-B38E07712148\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"\\nA command injection vulnerability exists where an authenticated, remote attacker with administrator privileges on the Security Center application could modify Logging parameters, which could lead to the execution of arbitrary code on the Security Center host. \\n\\n\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad de inyecci\\u00f3n de comandos donde un atacante remoto autenticado con privilegios de administrador en la aplicaci\\u00f3n Security Center podr\\u00eda modificar los par\\u00e1metros de registro, lo que podr\\u00eda conducir a la ejecuci\\u00f3n de c\\u00f3digo arbitrario en el host de Security Center.\"}]",
"id": "CVE-2024-1367",
"lastModified": "2024-11-21T08:50:25.600",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"vulnreport@tenable.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 5.9}]}",
"published": "2024-02-14T22:15:47.753",
"references": "[{\"url\": \"https://www.tenable.com/security/tns-2024-02\", \"source\": \"vulnreport@tenable.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.tenable.com/security/tns-2024-02\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"vulnreport@tenable.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-1367\",\"sourceIdentifier\":\"vulnreport@tenable.com\",\"published\":\"2024-02-14T22:15:47.753\",\"lastModified\":\"2024-11-21T08:50:25.600\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA command injection vulnerability exists where an authenticated, remote attacker with administrator privileges on the Security Center application could modify Logging parameters, which could lead to the execution of arbitrary code on the Security Center host. \\n\\n\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de inyecci\u00f3n de comandos donde un atacante remoto autenticado con privilegios de administrador en la aplicaci\u00f3n Security Center podr\u00eda modificar los par\u00e1metros de registro, lo que podr\u00eda conducir a la ejecuci\u00f3n de c\u00f3digo arbitrario en el host de Security Center.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"vulnreport@tenable.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"vulnreport@tenable.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:tenable:security_center:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.3.0\",\"matchCriteriaId\":\"E4F24FE6-9C35-4B06-99E7-B38E07712148\"}]}]}],\"references\":[{\"url\":\"https://www.tenable.com/security/tns-2024-02\",\"source\":\"vulnreport@tenable.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.tenable.com/security/tns-2024-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.tenable.com/security/tns-2024-02\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T18:40:19.949Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-1367\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-02-15T20:05:10.392514Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-05-02T16:26:00.338Z\"}}], \"cna\": {\"title\": \"Command Injection Vulnerability in Tenable Security Center\", \"source\": {\"advisory\": \"TNS-2024-02\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Pawe\\u0142 Bednarz\"}], \"impacts\": [{\"capecId\": \"CAPEC-248\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-248 Command Injection\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.2, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Tenable\", \"product\": \"Security Center\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"6.3.0\", \"versionType\": \"6.3.0\"}], \"platforms\": [\"Linux\"], \"defaultStatus\": \"affected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"\\nTenable has released Security Center 6.3.0 to address these issues. The installation files can be obtained from the Tenable Downloads Portal: https://www.tenable.com/downloads/security-center https://www.tenable.com/downloads/security-center \\n\\n\\n\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eTenable has released Security Center 6.3.0 to address these issues. The installation files can be obtained from the Tenable Downloads Portal: \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.tenable.com/downloads/security-center\\\"\u003ehttps://www.tenable.com/downloads/security-center\u003c/a\u003e\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\", \"base64\": false}]}], \"datePublic\": \"2024-02-14T19:00:00.000Z\", \"references\": [{\"url\": \"https://www.tenable.com/security/tns-2024-02\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nA command injection vulnerability exists where an authenticated, remote attacker with administrator privileges on the Security Center application could modify Logging parameters, which could lead to the execution of arbitrary code on the Security Center host. \\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\nA command injection vulnerability exists where an authenticated, remote attacker with administrator privileges on the Security Center application could modify Logging parameters, which could lead to the execution of arbitrary code on the Security Center host. \\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"5ac1ecc2-367a-4d16-a0b2-35d495ddd0be\", \"shortName\": \"tenable\", \"dateUpdated\": \"2024-02-14T21:35:16.767Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-1367\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-05-02T16:26:07.235Z\", \"dateReserved\": \"2024-02-08T19:43:20.585Z\", \"assignerOrgId\": \"5ac1ecc2-367a-4d16-a0b2-35d495ddd0be\", \"datePublished\": \"2024-02-14T21:35:16.767Z\", \"assignerShortName\": \"tenable\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…