CVE-2024-14036 (GCVE-0-2024-14036)
Vulnerability from cvelistv5 – Published: 2026-06-02 21:22 – Updated: 2026-06-03 20:19- CWE-400 - Uncontrolled Resource Consumption
| URL | Tags |
|---|---|
| https://static.draeger.com/security/download/PSA-… | vendor-advisory |
| https://www.vulncheck.com/advisories/dr-ger-core-… | third-party-advisory |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Dräger | Core |
Affected:
0 , ≤ 1.0.5
(custom)
|
guessed | |
| Dräger | M540 Converter Service |
Affected:
0 , ≤ 1.0.9
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-14036",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-03T13:33:43.540807Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-03T13:33:51.422Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Core",
"vendor": "Dr\u00e4ger",
"versions": [
{
"lessThanOrEqual": "1.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "M540 Converter Service",
"vendor": "Dr\u00e4ger",
"versions": [
{
"lessThanOrEqual": "1.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2024-04-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eDr\u00e4ger Core 1.0.5 and Dr\u00e4ger M540 Converter Service 1.0.9 contain a denial of service vulnerability that allows network-adjacent attackers to trigger high CPU load by sending specially crafted, unencrypted SDC messages during the discovery process. Attackers with access to the hospital network can send malformed SDC packets to exhaust CPU resources in the affected process, causing further SDC messages to no longer be processed.\u003c/p\u003e"
}
],
"value": "Dr\u00e4ger Core 1.0.5 and Dr\u00e4ger M540 Converter Service 1.0.9 contain a denial of service vulnerability that allows network-adjacent attackers to trigger high CPU load by sending specially crafted, unencrypted SDC messages during the discovery process. Attackers with access to the hospital network can send malformed SDC packets to exhaust CPU resources in the affected process, causing further SDC messages to no longer be processed."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-03T20:19:30.418Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://static.draeger.com/security/download/PSA-24-110-1-gSOAP-Product-Security-Advisory.pdf"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/dr-ger-core-denial-of-service-via-malformed-sdc-message"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Dr\u00e4ger Core 1.0.5 Denial of Service via Malformed SDC Message",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2024-14036",
"datePublished": "2026-06-02T21:22:12.578Z",
"dateReserved": "2026-06-02T21:19:56.497Z",
"dateUpdated": "2026-06-03T20:19:30.418Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-14036",
"date": "2026-11-15",
"epss": "0.00284",
"percentile": "0.21199"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "Core",
"vendor": "Dr\u00e4ger",
"versions": [
{
"lessThanOrEqual": "1.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "M540 Converter Service",
"vendor": "Dr\u00e4ger",
"versions": [
{
"lessThanOrEqual": "1.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "disclosure@vulncheck.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dr\u00e4ger Core 1.0.5 and Dr\u00e4ger M540 Converter Service 1.0.9 contain a denial of service vulnerability that allows network-adjacent attackers to trigger high CPU load by sending specially crafted, unencrypted SDC messages during the discovery process. Attackers with access to the hospital network can send malformed SDC packets to exhaust CPU resources in the affected process, causing further SDC messages to no longer be processed."
},
{
"lang": "es",
"value": "Dr\u00e4ger Core 1.0.5 y Dr\u00e4ger M540 Converter Service 1.0.9 contienen una vulnerabilidad de denegaci\u00f3n de servicio que permite a atacantes adyacentes a la red desencadenar una alta carga de CPU enviando mensajes SDC especialmente dise\u00f1ados y sin cifrar durante el proceso de descubrimiento. Atacantes con acceso a la red del hospital pueden enviar paquetes SDC malformados para agotar los recursos de CPU en el proceso afectado, provocando que los mensajes SDC posteriores dejen de procesarse."
}
],
"id": "CVE-2024-14036",
"lastModified": "2026-07-22T19:10:00.120",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-14036",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-03T13:33:43.540807Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-06-02T22:16:15.820",
"references": [
{
"source": "disclosure@vulncheck.com",
"url": "https://static.draeger.com/security/download/PSA-24-110-1-gSOAP-Product-Security-Advisory.pdf"
},
{
"source": "disclosure@vulncheck.com",
"url": "https://www.vulncheck.com/advisories/dr-ger-core-denial-of-service-via-malformed-sdc-message"
}
],
"sourceIdentifier": "disclosure@vulncheck.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
],
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-06-03T22:01:17+00:00",
"cve": "CVE-2024-14036",
"id": "CVE-2024-14036",
"initial_release_date": "2024-04-22T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Dr\u00e4ger Core 1.0.5 Denial of Service via Malformed SDC Message",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-14036.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-14036",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-03T13:33:43.540807Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-03T13:33:48.672Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Core",
"vendor": "Dr\u00e4ger",
"versions": [
{
"lessThanOrEqual": "1.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "M540 Converter Service",
"vendor": "Dr\u00e4ger",
"versions": [
{
"lessThanOrEqual": "1.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2024-04-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eDr\u00e4ger Core 1.0.5 and Dr\u00e4ger M540 Converter Service 1.0.9 contain a denial of service vulnerability that allows network-adjacent attackers to trigger high CPU load by sending specially crafted, unencrypted SDC messages during the discovery process. Attackers with access to the hospital network can send malformed SDC packets to exhaust CPU resources in the affected process, causing further SDC messages to no longer be processed.\u003c/p\u003e"
}
],
"value": "Dr\u00e4ger Core 1.0.5 and Dr\u00e4ger M540 Converter Service 1.0.9 contain a denial of service vulnerability that allows network-adjacent attackers to trigger high CPU load by sending specially crafted, unencrypted SDC messages during the discovery process. Attackers with access to the hospital network can send malformed SDC packets to exhaust CPU resources in the affected process, causing further SDC messages to no longer be processed."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-03T20:19:30.418Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://static.draeger.com/security/download/PSA-24-110-1-gSOAP-Product-Security-Advisory.pdf"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/dr-ger-core-denial-of-service-via-malformed-sdc-message"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Dr\u00e4ger Core 1.0.5 Denial of Service via Malformed SDC Message",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2024-14036",
"datePublished": "2026-06-02T21:22:12.578Z",
"dateReserved": "2026-06-02T21:19:56.497Z",
"dateUpdated": "2026-06-03T20:19:30.418Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.