CVE-2024-21767
Vulnerability from cvelistv5
Published
2024-03-01 20:54
Modified
2024-08-12 20:25
Severity ?
EPSS score ?
Summary
Commend WS203VICM Improper Access Control
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T22:27:36.216Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-051-01" }, { "tags": [ "x_transferred" ], "url": "https://clibrary-online.commend.com/en/cyber-security/security-advisories.html" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:commend:ws203vicm_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ws203vicm_firmware", "vendor": "commend", "versions": [ { "lessThanOrEqual": "1.7", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-21767", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-03-07T17:04:35.609970Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-12T20:25:25.781Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "WS203VICM", "vendor": "Commend", "versions": [ { "lessThanOrEqual": "1.7", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Aar\u00f3n Flecha Men\u00e9ndez of S21sec reported these vulnerabilities to CISA." } ], "datePublic": "2024-02-20T20:48:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA remote attacker may be able to bypass access control of Commend WS203VICM by creating a malicious request.\n\n\n\n" } ], "value": "\nA remote attacker may be able to bypass access control of Commend WS203VICM by creating a malicious request.\n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.4, "baseSeverity": "CRITICAL", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-01T20:54:48.538Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-051-01" }, { "url": "https://clibrary-online.commend.com/en/cyber-security/security-advisories.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\nAlthough this is an end-of-life product, Commend has created new firmware \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://clibrary-online.commend.com/\"\u003eversion WS-CM 2.0\u003c/a\u003e\u0026nbsp;\u003cspan style=\"background-color: var(--wht);\"\u003e\u0026nbsp;to\n address the first two issues. The new firmware can be loaded via the \nprogram \"IP Station Config\". To install the firmware, follow the \ninstructions below:\u003c/span\u003e\u003col\u003e\n\u003cli\u003eLog in to the Commend web-portal.\u003c/li\u003e\n\u003cli\u003eDownload and extract the \"Terminals Software Package\".\u003c/li\u003e\n\u003cli\u003eIn \"IP Station Config\", select the stations to be updated in the table.\u003c/li\u003e\n\u003cli\u003eGo to: Menu Station \u0026gt; Firmware Download\u003c/li\u003e\n\u003cli\u003eSelect the file \"WS-CM 2.0.geh\" from the folder \"WS-CM\" and click on the button Open.\u003c/li\u003e\n\u003c/ol\u003e\n\u003cp\u003eFor additional information, please visit \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://clibrary-online.commend.com/en/cyber-security/security-advisories.html\"\u003eCSA-2024-42 on Commend\u0027s cybersecurity website.\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e" } ], "value": "Although this is an end-of-life product, Commend has created new firmware version WS-CM 2.0 https://clibrary-online.commend.com/ \u00a0\u00a0to\n address the first two issues. The new firmware can be loaded via the \nprogram \"IP Station Config\". To install the firmware, follow the \ninstructions below:\n * Log in to the Commend web-portal.\n\n * Download and extract the \"Terminals Software Package\".\n\n * In \"IP Station Config\", select the stations to be updated in the table.\n\n * Go to: Menu Station \u003e Firmware Download\n\n * Select the file \"WS-CM 2.0.geh\" from the folder \"WS-CM\" and click on the button Open.\n\n\nFor additional information, please visit CSA-2024-42 on Commend\u0027s cybersecurity website. https://clibrary-online.commend.com/en/cyber-security/security-advisories.html \n\n\n\n\n" } ], "source": { "advisory": "ICSA-24-051-01", "discovery": "EXTERNAL" }, "tags": [ "unsupported-when-assigned" ], "title": "Commend WS203VICM Improper Access Control", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2024-21767", "datePublished": "2024-03-01T20:54:48.538Z", "dateReserved": "2024-01-30T22:06:32.537Z", "dateUpdated": "2024-08-12T20:25:25.781Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-21767\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2024-03-01T21:15:07.973\",\"lastModified\":\"2024-08-12T21:15:31.630\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[{\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"unsupported-when-assigned\"]}],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA remote attacker may be able to bypass access control of Commend WS203VICM by creating a malicious request.\\n\\n\\n\\n\"},{\"lang\":\"es\",\"value\":\"Un atacante remoto puede eludir el control de acceso de Commend WS203VICM creando una solicitud maliciosa.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.4,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.5}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]}],\"references\":[{\"url\":\"https://clibrary-online.commend.com/en/cyber-security/security-advisories.html\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-24-051-01\",\"source\":\"ics-cert@hq.dhs.gov\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.