Summary
MicroDicom DICOM Viewer Out-of-Bounds Write
References
Impacted products
▼ | Vendor | Product |
---|---|---|
MicroDicom | DICOM Viewer |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T23:44:09.577Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-060-01" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:a:microdicom:dicom_viewer:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "dicom_viewer", "vendor": "microdicom", "versions": [ { "lessThan": "2023.3_build_9342", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-25578", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-03-01T15:51:42.915559Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-12T20:21:12.703Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "DICOM Viewer", "vendor": "MicroDicom", "versions": [ { "lessThanOrEqual": " 2023.3 (Build 9342)", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Michael Heinzl reported these vulnerabilities to CISA." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMicroDicom DICOM Viewer versions 2023.3 (Build 9342) and prior contain a lack of proper validation of user-supplied data, which could result in memory corruption within the application.\u003c/span\u003e\n\n\u003c/span\u003e\n\n" } ], "value": "\n\n\nMicroDicom DICOM Viewer versions 2023.3 (Build 9342) and prior contain a lack of proper validation of user-supplied data, which could result in memory corruption within the application.\n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-01T00:40:00.677Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-060-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cp\u003eMicroDicom has provided a fix and recommends users upgrade to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.microdicom.com/\"\u003e2024.1\u003c/a\u003e.\u003c/p\u003e\u003cp\u003eFor additional assistance, \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.microdicom.com/contacts.html\"\u003econtact MicroDicom\u003c/a\u003e\u0026nbsp;directly\u003c/p\u003e\n\n\u003cbr\u003e" } ], "value": "\nMicroDicom has provided a fix and recommends users upgrade to 2024.1 https://www.microdicom.com/ .\n\nFor additional assistance, contact MicroDicom https://www.microdicom.com/contacts.html \u00a0directly\n\n\n\n\n" } ], "source": { "discovery": "EXTERNAL" }, "title": "MicroDicom DICOM Viewer Out-of-Bounds Write", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2024-25578", "datePublished": "2024-03-01T00:40:00.677Z", "dateReserved": "2024-02-12T16:22:12.773Z", "dateUpdated": "2024-08-12T20:21:12.703Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-25578\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2024-03-01T01:15:07.550\",\"lastModified\":\"2024-03-01T14:04:26.010\",\"vulnStatus\":\"Awaiting Analysis\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\n\\n\\nMicroDicom DICOM Viewer versions 2023.3 (Build 9342) and prior contain a lack of proper validation of user-supplied data, which could result in memory corruption within the application.\\n\\n\\n\\n\"},{\"lang\":\"es\",\"value\":\"MicroDicom DICOM Viewer versiones 2023.3 (compilaci\u00f3n 9342) y anteriores contienen una falta de validaci\u00f3n adecuada de los datos proporcionados por el usuario, lo que podr\u00eda provocar da\u00f1os en la memoria dentro de la aplicaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"references\":[{\"url\":\"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-060-01\",\"source\":\"ics-cert@hq.dhs.gov\"}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.