CVE-2024-31954 (GCVE-0-2024-31954)

Vulnerability from cvelistv5 – Published: 2024-05-09 17:45 – Updated: 2025-02-13 15:48
VLAI?
Summary
An issue was discovered in the installer in Samsung Portable SSD for T5 1.6.10 on Windows. Because it is possible to tamper with the directory and DLL files used during the installation process, an attacker can escalate privileges through arbitrary code execution. (An attacker must already have user privileges)
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:samsung:Samsung_Portable_SSD_T5_Software_for_Windows:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "Samsung_Portable_SSD_T5_Software_for_Windows",
            "vendor": "samsung",
            "versions": [
              {
                "status": "affected",
                "version": "1.6.10"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-31954",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-10T13:52:53.071658Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-538",
                "description": "CWE-538 Insertion of Sensitive Information into Externally-Accessible File or Directory",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:36:35.013Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:59:50.570Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://semiconductor.samsung.com/support/quality-support/product-security-updates/cve-2024-31954/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in the installer in Samsung Portable SSD for T5 1.6.10 on Windows. Because it is possible to tamper with the directory and DLL files used during the installation process, an attacker can escalate privileges through arbitrary code execution. (An attacker must already have user privileges)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:L/AV:L/A:H/C:H/I:H/PR:L/S:U/UI:R",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-09T17:45:33.948Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://semiconductor.samsung.com/support/quality-support/product-security-updates/cve-2024-31954/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-31954",
    "datePublished": "2024-05-09T17:45:33.660Z",
    "dateReserved": "2024-04-08T00:00:00.000Z",
    "dateUpdated": "2025-02-13T15:48:01.868Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "descriptions": "[{\"lang\": \"en\", \"value\": \"An issue was discovered in the installer in Samsung Portable SSD for T5 1.6.10 on Windows. Because it is possible to tamper with the directory and DLL files used during the installation process, an attacker can escalate privileges through arbitrary code execution. (An attacker must already have user privileges)\"}, {\"lang\": \"es\", \"value\": \"Se descubri\\u00f3 un problema en el instalador de Samsung Portable SSD para T5 1.6.10 en Windows. Debido a que es posible alterar el directorio y los archivos DLL utilizados durante el proceso de instalaci\\u00f3n, un atacante puede aumentar los privilegios mediante la ejecuci\\u00f3n de c\\u00f3digo arbitrario. (Un atacante ya debe tener privilegios de usuario)\"}]",
      "id": "CVE-2024-31954",
      "lastModified": "2024-11-21T09:14:12.007",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"cve@mitre.org\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.3, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.3, \"impactScore\": 5.9}]}",
      "published": "2024-05-14T15:30:12.197",
      "references": "[{\"url\": \"https://semiconductor.samsung.com/support/quality-support/product-security-updates/cve-2024-31954/\", \"source\": \"cve@mitre.org\"}, {\"url\": \"https://semiconductor.samsung.com/support/quality-support/product-security-updates/cve-2024-31954/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": "[{\"source\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-538\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-31954\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2024-05-14T15:30:12.197\",\"lastModified\":\"2024-11-21T09:14:12.007\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered in the installer in Samsung Portable SSD for T5 1.6.10 on Windows. Because it is possible to tamper with the directory and DLL files used during the installation process, an attacker can escalate privileges through arbitrary code execution. (An attacker must already have user privileges)\"},{\"lang\":\"es\",\"value\":\"Se descubri\u00f3 un problema en el instalador de Samsung Portable SSD para T5 1.6.10 en Windows. Debido a que es posible alterar el directorio y los archivos DLL utilizados durante el proceso de instalaci\u00f3n, un atacante puede aumentar los privilegios mediante la ejecuci\u00f3n de c\u00f3digo arbitrario. (Un atacante ya debe tener privilegios de usuario)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.3,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-538\"}]}],\"references\":[{\"url\":\"https://semiconductor.samsung.com/support/quality-support/product-security-updates/cve-2024-31954/\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://semiconductor.samsung.com/support/quality-support/product-security-updates/cve-2024-31954/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
    "vulnrichment": {
      "containers": "{\"cna\": {\"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2024-05-09T17:45:33.948487\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An issue was discovered in the installer in Samsung Portable SSD for T5 1.6.10 on Windows. Because it is possible to tamper with the directory and DLL files used during the installation process, an attacker can escalate privileges through arbitrary code execution. (An attacker must already have user privileges)\"}], \"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"version\": \"n/a\", \"status\": \"affected\"}]}], \"references\": [{\"url\": \"https://semiconductor.samsung.com/support/quality-support/product-security-updates/cve-2024-31954/\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AC:L/AV:L/A:H/C:H/I:H/PR:L/S:U/UI:R\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"baseScore\": 7.3, \"baseSeverity\": \"HIGH\"}}], \"problemTypes\": [{\"descriptions\": [{\"type\": \"text\", \"lang\": \"en\", \"description\": \"n/a\"}]}]}, \"adp\": [{\"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-31954\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-05-10T13:52:53.071658Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:samsung:Samsung_Portable_SSD_T5_Software_for_Windows:*:*:*:*:*:*:*:*\"], \"vendor\": \"samsung\", \"product\": \"Samsung_Portable_SSD_T5_Software_for_Windows\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.6.10\"}], \"defaultStatus\": \"unknown\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-538\", \"description\": \"CWE-538 Insertion of Sensitive Information into Externally-Accessible File or Directory\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-05-10T13:56:47.932Z\"}, \"title\": \"CISA ADP Vulnrichment\"}]}",
      "cveMetadata": "{\"state\": \"PUBLISHED\", \"cveId\": \"CVE-2024-31954\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"assignerShortName\": \"mitre\", \"dateUpdated\": \"2024-06-04T17:36:35.013Z\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…