Summary
Cleartext storage of sensitive information vulnerability exists in WindLDR and WindO/I-NV4. If this vulnerability is exploited, an attacker who obtained the product's project file may obtain user credentials of the PLC or Operator Interfaces. As a result, an attacker may be able to manipulate and/or suspend the PLC and Operator Interfaces by accessing or hijacking them.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-04 13:58 UTC
CWE
  • Cleartext storage of sensitive information
  • CWE-312 - Cleartext Storage of Sensitive Information
Impacted products
Vendor Product Version CPE status
IDEC Corporation WindLDR Affected: Ver.9.1.0 and earlier
guessed Create a notification for this product.
IDEC Corporation WindO/I-NV4 Affected: Ver.3.0.1
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 8.1,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-41716",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-04T13:58:55.637135Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-312",
                "description": "CWE-312 Cleartext Storage of Sensitive Information",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-13T14:15:40.744Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WindLDR",
          "vendor": "IDEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Ver.9.1.0 and earlier"
            }
          ]
        },
        {
          "product": "WindO/I-NV4",
          "vendor": "IDEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Ver.3.0.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Cleartext storage of sensitive information vulnerability exists in WindLDR and WindO/I-NV4. If this vulnerability is exploited, an attacker who obtained the product\u0027s project file may obtain user credentials of the PLC or Operator Interfaces. As a result, an attacker may be able to manipulate and/or suspend the PLC and Operator Interfaces by accessing or hijacking them."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Cleartext storage of sensitive information",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-04T00:34:12.610Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://us.idec.com/media/24-RD-0219-EN.pdf"
        },
        {
          "url": "https://jvn.jp/en/jp/JVN08342147/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2024-41716",
    "datePublished": "2024-09-04T00:34:12.610Z",
    "dateReserved": "2024-08-01T01:18:08.236Z",
    "dateUpdated": "2025-03-13T14:15:40.744Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-41716",
      "date": "2026-09-19",
      "epss": "0.00447",
      "percentile": "0.38217"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:idec:windldr:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3A8085E3-47BE-471B-9752-1B0B7482954B",
                  "versionEndExcluding": "9.2.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:idec:windo\\/i-nv4:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2778FEF8-6239-40F4-8E1F-B9AEBA9711FD",
                  "versionEndExcluding": "3.1.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Cleartext storage of sensitive information vulnerability exists in WindLDR and WindO/I-NV4. If this vulnerability is exploited, an attacker who obtained the product\u0027s project file may obtain user credentials of the PLC or Operator Interfaces. As a result, an attacker may be able to manipulate and/or suspend the PLC and Operator Interfaces by accessing or hijacking them."
        },
        {
          "lang": "es",
          "value": "Existe una vulnerabilidad de almacenamiento de texto plano de informaci\u00f3n confidencial en WindLDR y WindO/I-NV4. Si se explota esta vulnerabilidad, un atacante que haya obtenido el archivo de proyecto del producto puede obtener las credenciales de usuario del PLC o las interfaces del operador. Como resultado, un atacante puede manipular y/o suspender el PLC y las interfaces del operador accediendo a ellos o secuestr\u00e1ndolos."
        }
      ],
      "id": "CVE-2024-41716",
      "lastModified": "2024-09-13T19:53:47.723",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 8.1,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.2,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2024-09-04T01:15:11.747",
      "references": [
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/en/jp/JVN08342147/"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://us.idec.com/media/24-RD-0219-EN.pdf"
        }
      ],
      "sourceIdentifier": "vultures@jpcert.or.jp",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-312"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "WindLDR",
                "vendor": "IDEC Corporation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "Ver.9.1.0 and earlier"
                  }
                ]
              },
              {
                "product": "WindO/I-NV4",
                "vendor": "IDEC Corporation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "Ver.3.0.1"
                  }
                ]
              }
            ],
            "source": "vultures@jpcert.or.jp"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:idec:windldr:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3A8085E3-47BE-471B-9752-1B0B7482954B",
                    "versionEndExcluding": "9.2.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:idec:windo\\/i-nv4:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2778FEF8-6239-40F4-8E1F-B9AEBA9711FD",
                    "versionEndExcluding": "3.1.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Cleartext storage of sensitive information vulnerability exists in WindLDR and WindO/I-NV4. If this vulnerability is exploited, an attacker who obtained the product\u0027s project file may obtain user credentials of the PLC or Operator Interfaces. As a result, an attacker may be able to manipulate and/or suspend the PLC and Operator Interfaces by accessing or hijacking them."
          },
          {
            "lang": "es",
            "value": "Existe una vulnerabilidad de almacenamiento de texto plano de informaci\u00f3n confidencial en WindLDR y WindO/I-NV4. Si se explota esta vulnerabilidad, un atacante que haya obtenido el archivo de proyecto del producto puede obtener las credenciales de usuario del PLC o las interfaces del operador. Como resultado, un atacante puede manipular y/o suspender el PLC y las interfaces del operador accediendo a ellos o secuestr\u00e1ndolos."
          }
        ],
        "id": "CVE-2024-41716",
        "lastModified": "2026-06-17T07:48:06.977",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.2,
              "source": "nvd@nist.gov",
              "type": "Primary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.2,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-41716",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-04T13:58:55.637135Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-09-04T01:15:11.747",
        "references": [
          {
            "source": "vultures@jpcert.or.jp",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://jvn.jp/en/jp/JVN08342147/"
          },
          {
            "source": "vultures@jpcert.or.jp",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://us.idec.com/media/24-RD-0219-EN.pdf"
          }
        ],
        "sourceIdentifier": "vultures@jpcert.or.jp",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-312"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-312"
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T21:22:12+00:00",
      "cve": "CVE-2024-41716",
      "id": "CVE-2024-41716",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2024-41716",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-41716.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 8.1,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-41716",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-04T13:58:55.637135Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-312",
                    "description": "CWE-312 Cleartext Storage of Sensitive Information",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-04T13:59:00.272Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "WindLDR",
              "vendor": "IDEC Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.9.1.0 and earlier"
                }
              ]
            },
            {
              "product": "WindO/I-NV4",
              "vendor": "IDEC Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.3.0.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Cleartext storage of sensitive information vulnerability exists in WindLDR and WindO/I-NV4. If this vulnerability is exploited, an attacker who obtained the product\u0027s project file may obtain user credentials of the PLC or Operator Interfaces. As a result, an attacker may be able to manipulate and/or suspend the PLC and Operator Interfaces by accessing or hijacking them."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Cleartext storage of sensitive information",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-09-04T00:34:12.610Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://us.idec.com/media/24-RD-0219-EN.pdf"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN08342147/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2024-41716",
        "datePublished": "2024-09-04T00:34:12.610Z",
        "dateReserved": "2024-08-01T01:18:08.236Z",
        "dateUpdated": "2025-03-13T14:15:40.744Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…