GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2024-41911 (GCVE-0-2024-41911)

Vulnerability from cvelistv5 – Published: 2024-08-06 14:07 – Updated: 2024-10-28 20:23
VLAI
Summary
A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The flaw does not properly neutralize input during a web page generation.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-06 15:52 UTC
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version CPE status
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.4,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-41911",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-06T15:52:22.228928Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-79",
                "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-28T20:23:13.420Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The flaw does not properly neutralize input during a web page generation."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-06T14:07:33.637Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_11006770-11006795-16/hpsbpy03959"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2024-41911",
    "datePublished": "2024-08-06T14:07:33.637Z",
    "dateReserved": "2024-07-23T15:33:15.305Z",
    "dateUpdated": "2024-10-28T20:23:13.420Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-41911",
      "date": "2026-09-17",
      "epss": "0.00257",
      "percentile": "0.17551"
    },
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:hp:poly_clariti_manager_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"10.10.2.2\", \"matchCriteriaId\": \"1ECAA137-00B5-48AA-9D9B-F5ACD13D4CF4\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hp:poly_clariti_manager:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A4A692C6-384C-4802-A6A2-4881B4B73A7B\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The flaw does not properly neutralize input during a web page generation.\"}, {\"lang\": \"es\", \"value\": \"Se descubri\\u00f3 una vulnerabilidad en las versiones de firmware hasta 10.10.2.2 en dispositivos Poly Clariti Manager. La falla no neutraliza adecuadamente la entrada durante la generaci\\u00f3n de una p\\u00e1gina web.\"}]",
      "id": "CVE-2024-41911",
      "lastModified": "2024-10-28T21:35:14.540",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 5.4, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 2.7}, {\"source\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 5.4, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 2.7}]}",
      "published": "2024-08-06T14:16:04.427",
      "references": "[{\"url\": \"https://support.hp.com/us-en/document/ish_11006770-11006795-16/hpsbpy03959\", \"source\": \"hp-security-alert@hp.com\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "hp-security-alert@hp.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}, {\"source\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-41911\",\"sourceIdentifier\":\"hp-security-alert@hp.com\",\"published\":\"2024-08-06T14:16:04.427\",\"lastModified\":\"2026-06-17T07:48:26.260\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The flaw does not properly neutralize input during a web page generation.\"},{\"lang\":\"es\",\"value\":\"Se descubri\u00f3 una vulnerabilidad en las versiones de firmware hasta 10.10.2.2 en dispositivos Poly Clariti Manager. La falla no neutraliza adecuadamente la entrada durante la generaci\u00f3n de una p\u00e1gina web.\"}],\"affected\":[{\"source\":\"hp-security-alert@hp.com\",\"affectedData\":[{\"vendor\":\"HP Inc.\",\"product\":\"Poly Clariti Manager\",\"versions\":[{\"version\":\"See HP Security Bulletin reference for affected versions.\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2024-08-06T15:52:22.228928Z\",\"id\":\"CVE-2024-41911\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"partial\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:poly_clariti_manager:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"10.12.0.2_100\",\"matchCriteriaId\":\"01297D80-BD62-405F-B5AC-934060D6696F\"}]}]}],\"references\":[{\"url\":\"https://support.hp.com/us-en/document/ish_11006770-11006795-16/hpsbpy03959\",\"source\":\"hp-security-alert@hp.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "redhat_vex": {
      "current_release_date": "2025-05-28T20:06:08+00:00",
      "cve": "CVE-2024-41911",
      "id": "CVE-2024-41911",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2024-41911",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-41911.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 5.4, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-41911\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-08-06T15:52:22.228928Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-08-06T15:52:33.605Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"HP Inc.\", \"product\": \"Poly Clariti Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"See HP Security Bulletin reference for affected versions.\"}]}], \"references\": [{\"url\": \"https://support.hp.com/us-en/document/ish_11006770-11006795-16/hpsbpy03959\"}], \"x_generator\": {\"engine\": \"cveClient/1.0.15\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The flaw does not properly neutralize input during a web page generation.\"}], \"providerMetadata\": {\"orgId\": \"74586083-13ce-40fd-b46a-8e5d23cfbcb2\", \"shortName\": \"hp\", \"dateUpdated\": \"2024-08-06T14:07:33.637Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-41911\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-28T20:23:13.420Z\", \"dateReserved\": \"2024-07-23T15:33:15.305Z\", \"assignerOrgId\": \"74586083-13ce-40fd-b46a-8e5d23cfbcb2\", \"datePublished\": \"2024-08-06T14:07:33.637Z\", \"assignerShortName\": \"hp\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…