CVE-2024-54126 (GCVE-0-2024-54126)
Vulnerability from cvelistv5 – Published: 2024-12-05 12:14 – Updated: 2024-12-05 16:37
VLAI?
Summary
This vulnerability exists in the TP-Link Archer C50 due to improper signature verification mechanism in the firmware upgrade process at its web interface. An attacker with administrative privileges within the router’s Wi-Fi range could exploit this vulnerability by uploading and executing malicious firmware which could lead to complete compromise of the targeted device.
Severity ?
CWE
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| TP-Link | Archer C50 Wireless Router |
Affected:
<Archer C50(EU)_V4_ 240917
|
Credits
This vulnerability is reported is reported by Khalid Markar, Amey Chavekar, Sushant Mane & Dr. Faruk Kazi from CoE-CNDS Lab, VJTI, Mumbai
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tp-link:archer_c50_firmware:c50\\(eu\\)_v4_240917:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "archer_c50_firmware",
"vendor": "tp-link",
"versions": [
{
"status": "affected",
"version": "c50\\(eu\\)_v4_240917"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-54126",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-05T15:56:14.433573Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-05T16:37:56.782Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Archer C50 Wireless Router",
"vendor": "TP-Link",
"versions": [
{
"status": "affected",
"version": "\u003cArcher C50(EU)_V4_ 240917"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This vulnerability is reported is reported by Khalid Markar, Amey Chavekar, Sushant Mane \u0026 Dr. Faruk Kazi from CoE-CNDS Lab, VJTI, Mumbai"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This vulnerability exists in the TP-Link Archer C50 due to improper signature verification mechanism in the firmware upgrade process at its web interface. An attacker with administrative privileges within the router\u2019s Wi-Fi range could exploit this vulnerability by uploading and executing malicious firmware which could lead to complete compromise of the targeted device."
}
],
"value": "This vulnerability exists in the TP-Link Archer C50 due to improper signature verification mechanism in the firmware upgrade process at its web interface. An attacker with administrative privileges within the router\u2019s Wi-Fi range could exploit this vulnerability by uploading and executing malicious firmware which could lead to complete compromise of the targeted device."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494: Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "CWE-347: Improper Verification of Cryptographic Signature",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-05T12:14:41.814Z",
"orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"shortName": "CERT-In"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2024-0354"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade to Archer C50(EU)_V4_ 240917\u003cbr\u003e\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://static.tp-link.com/upload/firmware/2024/202411/20241125/Archer%20C50(EU)_V4_240917.zip\"\u003ehttps://static.tp-link.com/upload/firmware/2024/202411/20241125/Archer%20C50(EU)_V4_240917.zip\u003c/a\u003e \u003cbr\u003e"
}
],
"value": "Upgrade to Archer C50(EU)_V4_ 240917\n\n https://static.tp-link.com/upload/firmware/2024/202411/20241125/Archer%20C50(EU)_V4_240917.zip"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Insufficient Integrity Verification Vulnerability in TP-Link Archer C50",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"assignerShortName": "CERT-In",
"cveId": "CVE-2024-54126",
"datePublished": "2024-12-05T12:14:41.814Z",
"dateReserved": "2024-11-29T11:09:33.863Z",
"dateUpdated": "2024-12-05T16:37:56.782Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"descriptions": "[{\"lang\": \"en\", \"value\": \"This vulnerability exists in the TP-Link Archer C50 due to improper signature verification mechanism in the firmware upgrade process at its web interface. An attacker with administrative privileges within the router\\u2019s Wi-Fi range could exploit this vulnerability by uploading and executing malicious firmware which could lead to complete compromise of the targeted device.\"}, {\"lang\": \"es\", \"value\": \"Esta vulnerabilidad existe en el TP-Link Archer C50 debido a un mecanismo de verificaci\\u00f3n de firma incorrecto en el proceso de actualizaci\\u00f3n de firmware en su interfaz web. Un atacante con privilegios administrativos dentro del rango de Wi-Fi del router podr\\u00eda aprovechar esta vulnerabilidad al cargar y ejecutar un firmware malicioso que podr\\u00eda provocar la vulneraci\\u00f3n total del dispositivo objetivo.\"}]",
"id": "CVE-2024-54126",
"lastModified": "2024-12-05T13:15:09.290",
"metrics": "{\"cvssMetricV40\": [{\"source\": \"vdisclose@cert-in.org.in\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"4.0\", \"vectorString\": \"CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\", \"baseScore\": 8.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"ADJACENT\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"vulnerableSystemConfidentiality\": \"HIGH\", \"vulnerableSystemIntegrity\": \"HIGH\", \"vulnerableSystemAvailability\": \"HIGH\", \"subsequentSystemConfidentiality\": \"NONE\", \"subsequentSystemIntegrity\": \"NONE\", \"subsequentSystemAvailability\": \"NONE\", \"exploitMaturity\": \"NOT_DEFINED\", \"confidentialityRequirements\": \"NOT_DEFINED\", \"integrityRequirements\": \"NOT_DEFINED\", \"availabilityRequirements\": \"NOT_DEFINED\", \"modifiedAttackVector\": \"NOT_DEFINED\", \"modifiedAttackComplexity\": \"NOT_DEFINED\", \"modifiedAttackRequirements\": \"NOT_DEFINED\", \"modifiedPrivilegesRequired\": \"NOT_DEFINED\", \"modifiedUserInteraction\": \"NOT_DEFINED\", \"modifiedVulnerableSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedVulnerableSystemIntegrity\": \"NOT_DEFINED\", \"modifiedVulnerableSystemAvailability\": \"NOT_DEFINED\", \"modifiedSubsequentSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedSubsequentSystemIntegrity\": \"NOT_DEFINED\", \"modifiedSubsequentSystemAvailability\": \"NOT_DEFINED\", \"safety\": \"NOT_DEFINED\", \"automatable\": \"NOT_DEFINED\", \"recovery\": \"NOT_DEFINED\", \"valueDensity\": \"NOT_DEFINED\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\"}}]}",
"published": "2024-12-05T13:15:09.290",
"references": "[{\"url\": \"https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2024-0354\", \"source\": \"vdisclose@cert-in.org.in\"}]",
"sourceIdentifier": "vdisclose@cert-in.org.in",
"vulnStatus": "Awaiting Analysis",
"weaknesses": "[{\"source\": \"vdisclose@cert-in.org.in\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-347\"}, {\"lang\": \"en\", \"value\": \"CWE-494\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-54126\",\"sourceIdentifier\":\"vdisclose@cert-in.org.in\",\"published\":\"2024-12-05T13:15:09.290\",\"lastModified\":\"2024-12-05T13:15:09.290\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"This vulnerability exists in the TP-Link Archer C50 due to improper signature verification mechanism in the firmware upgrade process at its web interface. An attacker with administrative privileges within the router\u2019s Wi-Fi range could exploit this vulnerability by uploading and executing malicious firmware which could lead to complete compromise of the targeted device.\"},{\"lang\":\"es\",\"value\":\"Esta vulnerabilidad existe en el TP-Link Archer C50 debido a un mecanismo de verificaci\u00f3n de firma incorrecto en el proceso de actualizaci\u00f3n de firmware en su interfaz web. Un atacante con privilegios administrativos dentro del rango de Wi-Fi del router podr\u00eda aprovechar esta vulnerabilidad al cargar y ejecutar un firmware malicioso que podr\u00eda provocar la vulneraci\u00f3n total del dispositivo objetivo.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"vdisclose@cert-in.org.in\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"vdisclose@cert-in.org.in\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-347\"},{\"lang\":\"en\",\"value\":\"CWE-494\"}]}],\"references\":[{\"url\":\"https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2024-0354\",\"source\":\"vdisclose@cert-in.org.in\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-54126\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-12-05T15:56:14.433573Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:tp-link:archer_c50_firmware:c50\\\\(eu\\\\)_v4_240917:*:*:*:*:*:*:*\"], \"vendor\": \"tp-link\", \"product\": \"archer_c50_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"c50\\\\(eu\\\\)_v4_240917\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-12-05T16:00:54.639Z\"}}], \"cna\": {\"title\": \"Insufficient Integrity Verification Vulnerability in TP-Link Archer C50\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"This vulnerability is reported is reported by Khalid Markar, Amey Chavekar, Sushant Mane \u0026 Dr. Faruk Kazi from CoE-CNDS Lab, VJTI, Mumbai\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.5, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"ADJACENT\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"TP-Link\", \"product\": \"Archer C50 Wireless Router\", \"versions\": [{\"status\": \"affected\", \"version\": \"\u003cArcher C50(EU)_V4_ 240917\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Upgrade to Archer C50(EU)_V4_ 240917\\n\\n https://static.tp-link.com/upload/firmware/2024/202411/20241125/Archer%20C50(EU)_V4_240917.zip\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Upgrade to Archer C50(EU)_V4_ 240917\u003cbr\u003e\u003cbr\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://static.tp-link.com/upload/firmware/2024/202411/20241125/Archer%20C50(EU)_V4_240917.zip\\\"\u003ehttps://static.tp-link.com/upload/firmware/2024/202411/20241125/Archer%20C50(EU)_V4_240917.zip\u003c/a\u003e \u003cbr\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2024-0354\", \"tags\": [\"third-party-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"This vulnerability exists in the TP-Link Archer C50 due to improper signature verification mechanism in the firmware upgrade process at its web interface. An attacker with administrative privileges within the router\\u2019s Wi-Fi range could exploit this vulnerability by uploading and executing malicious firmware which could lead to complete compromise of the targeted device.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"This vulnerability exists in the TP-Link Archer C50 due to improper signature verification mechanism in the firmware upgrade process at its web interface. An attacker with administrative privileges within the router\\u2019s Wi-Fi range could exploit this vulnerability by uploading and executing malicious firmware which could lead to complete compromise of the targeted device.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-494\", \"description\": \"CWE-494: Download of Code Without Integrity Check\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-347\", \"description\": \"CWE-347: Improper Verification of Cryptographic Signature\"}]}], \"providerMetadata\": {\"orgId\": \"66834db9-ab24-42b4-be80-296b2e40335c\", \"shortName\": \"CERT-In\", \"dateUpdated\": \"2024-12-05T12:14:41.814Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-54126\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-12-05T16:37:56.782Z\", \"dateReserved\": \"2024-11-29T11:09:33.863Z\", \"assignerOrgId\": \"66834db9-ab24-42b4-be80-296b2e40335c\", \"datePublished\": \"2024-12-05T12:14:41.814Z\", \"assignerShortName\": \"CERT-In\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…