CVE-2025-4994 (GCVE-0-2025-4994)
Vulnerability from cvelistv5 – Published: 2026-06-22 08:10 – Updated: 2026-07-07 09:05- CWE-305 - Authentication bypass by primary weakness
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| SafeLine | SafeLine SL6/SL6+ |
Affected:
4.82 , < 4.97
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-4994",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-22T12:25:04.852373Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-22T12:25:09.539Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2026-07-07T09:05:50.808Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2026/Jul/17"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SafeLine SL6/SL6+",
"vendor": "SafeLine",
"versions": [
{
"lessThan": "4.97",
"status": "affected",
"version": "4.82",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "The vulnerability was discovered by Jan H\u00fcber of SCHUTZWERK GmbH."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The SafeLine SL6 and SL6+ devices integrated into elevator emergency intercom systems are vulnerable to an authentication bypass. This vulnerability allows attackers to bypass authentication requirements and access the device\u0027s configuration service via the Bluetooth Low Energy (BLE) interface. Consequently, an attacker within wireless range can gain unauthorized administrative access to the device configuration."
}
],
"value": "The SafeLine SL6 and SL6+ devices integrated into elevator emergency intercom systems are vulnerable to an authentication bypass. This vulnerability allows attackers to bypass authentication requirements and access the device\u0027s configuration service via the Bluetooth Low Energy (BLE) interface. Consequently, an attacker within wireless range can gain unauthorized administrative access to the device configuration."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-305",
"description": "CWE-305 Authentication bypass by primary weakness",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-22T08:10:29.737Z",
"orgId": "23637b5d-af4c-4cf9-b8f6-deb7fd0f8423",
"shortName": "SCHUTZWERK"
},
"references": [
{
"url": "https://www.schutzwerk.com/en/blog/schutzwerk-sa-2025-001/"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A patch is available in firmware version 4.97 and should be applied immediately. This version removes the PIN authentication feature for BLE entirely. Access to the configuration interface via Bluetooth is only possible for a brief time window following a reboot, which is similar to the current behavior when disabling \"Auto Enable BLE\"."
}
],
"value": "A patch is available in firmware version 4.97 and should be applied immediately. This version removes the PIN authentication feature in BLE entirely. Access to the configuration interface via Bluetooth is only possible for a brief time window following a reboot, which is similar to the current behavior when disabling \"Auto Enable BLE\"."
}
],
"source": {
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2025-03-28T11:00:00.000Z",
"value": "Vulnerability discovered"
},
{
"lang": "en",
"time": "2025-04-14T10:00:00.000Z",
"value": "Initial contact with vendor"
},
{
"lang": "en",
"time": "2025-04-16T10:00:00.000Z",
"value": "Vulnerability reported to technical support of vendor"
},
{
"lang": "en",
"time": "2025-05-08T10:00:00.000Z",
"value": "Follow-up meeting was canceled by vendor"
},
{
"lang": "en",
"time": "2025-05-16T10:00:00.000Z",
"value": "Initial contact with CTO of vendor"
},
{
"lang": "en",
"time": "2025-05-28T10:00:00.000Z",
"value": "Vulnerability presented to CTO of vendor"
},
{
"lang": "en",
"time": "2025-06-16T10:00:00.000Z",
"value": "Vendor informed SCHUTZWERK that the patch was currently tested"
},
{
"lang": "en",
"time": "2025-07-03T10:00:00.000Z",
"value": "Follow-up meeting was canceled by vendor"
},
{
"lang": "en",
"time": "2025-07-31T10:00:00.000Z",
"value": "Follow-up meeting was requested by SCHUTZWERK"
},
{
"lang": "en",
"time": "2025-08-21T10:00:00.000Z",
"value": "Vendor informed SCHUTZWERK that the patch was postponed"
},
{
"lang": "en",
"time": "2025-08-28T10:00:00.000Z",
"value": "Vendor informed SCHUTZWERK that the patch was currently tested"
},
{
"lang": "en",
"time": "2025-12-19T11:00:00.000Z",
"value": "Vendor informed SCHUTZWERK that the patch was released"
},
{
"lang": "en",
"time": "2025-12-19T11:00:00.000Z",
"value": "Disclosure delayed for 180 days to allow patching the affected devices during scheduled maintenance windows"
},
{
"lang": "en",
"time": "2026-06-19T10:00:00.000Z",
"value": "Advisory released by SCHUTZWERK"
}
],
"title": "Authentication Bypass for SafeLine SL6 and SL6+",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The \"Auto Enable BLE\" setting should be disabled. This ensures that the BLE interface is deactivated after the initial time window, preventing wireless access to the configuration interface."
}
],
"value": "The \"Auto Enable BLE\" setting should be disabled. This ensures that the BLE interface is deactivated after the initial time window, preventing wireless access to the configuration interface."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.0-beta"
}
}
},
"cveMetadata": {
"assignerOrgId": "23637b5d-af4c-4cf9-b8f6-deb7fd0f8423",
"assignerShortName": "SCHUTZWERK",
"cveId": "CVE-2025-4994",
"datePublished": "2026-06-22T08:10:29.737Z",
"dateReserved": "2025-05-20T08:40:34.874Z",
"dateUpdated": "2026-07-07T09:05:50.808Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-4994",
"date": "2026-11-04",
"epss": "0.00331",
"percentile": "0.26452"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "SafeLine SL6/SL6+",
"vendor": "SafeLine",
"versions": [
{
"lessThan": "4.97",
"status": "affected",
"version": "4.82",
"versionType": "custom"
}
]
}
],
"source": "23637b5d-af4c-4cf9-b8f6-deb7fd0f8423"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The SafeLine SL6 and SL6+ devices integrated into elevator emergency intercom systems are vulnerable to an authentication bypass. This vulnerability allows attackers to bypass authentication requirements and access the device\u0027s configuration service via the Bluetooth Low Energy (BLE) interface. Consequently, an attacker within wireless range can gain unauthorized administrative access to the device configuration."
},
{
"lang": "es",
"value": "Los dispositivos SafeLine SL6 y SL6+ integrados en sistemas de intercomunicaci\u00f3n de emergencia de ascensores son vulnerables a una omisi\u00f3n de autenticaci\u00f3n. Esta vulnerabilidad permite a los atacantes omitir los requisitos de autenticaci\u00f3n y acceder al servicio de configuraci\u00f3n del dispositivo a trav\u00e9s de la interfaz Bluetooth de Baja Energ\u00eda (BLE). En consecuencia, un atacante dentro del alcance inal\u00e1mbrico puede obtener acceso administrativo no autorizado a la configuraci\u00f3n del dispositivo."
}
],
"id": "CVE-2025-4994",
"lastModified": "2026-10-06T22:10:00.247",
"metrics": {
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "23637b5d-af4c-4cf9-b8f6-deb7fd0f8423",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-4994",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-22T12:25:04.852373Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-06-22T10:16:17.673",
"references": [
{
"source": "23637b5d-af4c-4cf9-b8f6-deb7fd0f8423",
"url": "https://www.schutzwerk.com/en/blog/schutzwerk-sa-2025-001/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://seclists.org/fulldisclosure/2026/Jul/17"
}
],
"sourceIdentifier": "23637b5d-af4c-4cf9-b8f6-deb7fd0f8423",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-305"
}
],
"source": "23637b5d-af4c-4cf9-b8f6-deb7fd0f8423",
"type": "Secondary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2026-07-07T09:05:50.808Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2026/Jul/17"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-4994",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-22T12:25:04.852373Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-22T12:25:06.915Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SafeLine SL6/SL6+",
"vendor": "SafeLine",
"versions": [
{
"lessThan": "4.97",
"status": "affected",
"version": "4.82",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "The vulnerability was discovered by Jan H\u00fcber of SCHUTZWERK GmbH."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The SafeLine SL6 and SL6+ devices integrated into elevator emergency intercom systems are vulnerable to an authentication bypass. This vulnerability allows attackers to bypass authentication requirements and access the device\u0027s configuration service via the Bluetooth Low Energy (BLE) interface. Consequently, an attacker within wireless range can gain unauthorized administrative access to the device configuration."
}
],
"value": "The SafeLine SL6 and SL6+ devices integrated into elevator emergency intercom systems are vulnerable to an authentication bypass. This vulnerability allows attackers to bypass authentication requirements and access the device\u0027s configuration service via the Bluetooth Low Energy (BLE) interface. Consequently, an attacker within wireless range can gain unauthorized administrative access to the device configuration."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-305",
"description": "CWE-305 Authentication bypass by primary weakness",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-22T08:10:29.737Z",
"orgId": "23637b5d-af4c-4cf9-b8f6-deb7fd0f8423",
"shortName": "SCHUTZWERK"
},
"references": [
{
"url": "https://www.schutzwerk.com/en/blog/schutzwerk-sa-2025-001/"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A patch is available in firmware version 4.97 and should be applied immediately. This version removes the PIN authentication feature for BLE entirely. Access to the configuration interface via Bluetooth is only possible for a brief time window following a reboot, which is similar to the current behavior when disabling \"Auto Enable BLE\"."
}
],
"value": "A patch is available in firmware version 4.97 and should be applied immediately. This version removes the PIN authentication feature in BLE entirely. Access to the configuration interface via Bluetooth is only possible for a brief time window following a reboot, which is similar to the current behavior when disabling \"Auto Enable BLE\"."
}
],
"source": {
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2025-03-28T11:00:00.000Z",
"value": "Vulnerability discovered"
},
{
"lang": "en",
"time": "2025-04-14T10:00:00.000Z",
"value": "Initial contact with vendor"
},
{
"lang": "en",
"time": "2025-04-16T10:00:00.000Z",
"value": "Vulnerability reported to technical support of vendor"
},
{
"lang": "en",
"time": "2025-05-08T10:00:00.000Z",
"value": "Follow-up meeting was canceled by vendor"
},
{
"lang": "en",
"time": "2025-05-16T10:00:00.000Z",
"value": "Initial contact with CTO of vendor"
},
{
"lang": "en",
"time": "2025-05-28T10:00:00.000Z",
"value": "Vulnerability presented to CTO of vendor"
},
{
"lang": "en",
"time": "2025-06-16T10:00:00.000Z",
"value": "Vendor informed SCHUTZWERK that the patch was currently tested"
},
{
"lang": "en",
"time": "2025-07-03T10:00:00.000Z",
"value": "Follow-up meeting was canceled by vendor"
},
{
"lang": "en",
"time": "2025-07-31T10:00:00.000Z",
"value": "Follow-up meeting was requested by SCHUTZWERK"
},
{
"lang": "en",
"time": "2025-08-21T10:00:00.000Z",
"value": "Vendor informed SCHUTZWERK that the patch was postponed"
},
{
"lang": "en",
"time": "2025-08-28T10:00:00.000Z",
"value": "Vendor informed SCHUTZWERK that the patch was currently tested"
},
{
"lang": "en",
"time": "2025-12-19T11:00:00.000Z",
"value": "Vendor informed SCHUTZWERK that the patch was released"
},
{
"lang": "en",
"time": "2025-12-19T11:00:00.000Z",
"value": "Disclosure delayed for 180 days to allow patching the affected devices during scheduled maintenance windows"
},
{
"lang": "en",
"time": "2026-06-19T10:00:00.000Z",
"value": "Advisory released by SCHUTZWERK"
}
],
"title": "Authentication Bypass for SafeLine SL6 and SL6+",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The \"Auto Enable BLE\" setting should be disabled. This ensures that the BLE interface is deactivated after the initial time window, preventing wireless access to the configuration interface."
}
],
"value": "The \"Auto Enable BLE\" setting should be disabled. This ensures that the BLE interface is deactivated after the initial time window, preventing wireless access to the configuration interface."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.0-beta"
}
}
},
"cveMetadata": {
"assignerOrgId": "23637b5d-af4c-4cf9-b8f6-deb7fd0f8423",
"assignerShortName": "SCHUTZWERK",
"cveId": "CVE-2025-4994",
"datePublished": "2026-06-22T08:10:29.737Z",
"dateReserved": "2025-05-20T08:40:34.874Z",
"dateUpdated": "2026-07-07T09:05:50.808Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.