CVE-2025-67188 (GCVE-0-2025-67188)

Vulnerability from cvelistv5 – Published: 2026-02-03 00:00 – Updated: 2026-02-05 14:33
VLAI
Summary
A buffer overflow vulnerability exists in TOTOLINK A950RG V4.1.2cu.5204_B20210112. The issue resides in the setRadvdCfg interface of the /lib/cste_modules/ipv6.so module. The function fails to properly validate the length of the user-controlled radvdinterfacename parameter, allowing remote attackers to trigger a stack buffer overflow.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-05 14:32 UTC
CWE
  • n/a
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-67188",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-05T14:32:46.803630Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-120",
                "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-05T14:33:55.035Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A buffer overflow vulnerability exists in TOTOLINK A950RG V4.1.2cu.5204_B20210112. The issue resides in the setRadvdCfg interface of the /lib/cste_modules/ipv6.so module. The function fails to properly validate the length of the user-controlled radvdinterfacename parameter, allowing remote attackers to trigger a stack buffer overflow."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-03T17:40:19.303Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/ToTolink/A950RG/5024-ipv6-setRadvdCfg-radvdinterfacename-buffer.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-67188",
    "datePublished": "2026-02-03T00:00:00.000Z",
    "dateReserved": "2025-12-08T00:00:00.000Z",
    "dateUpdated": "2026-02-05T14:33:55.035Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-67188",
      "date": "2026-09-21",
      "epss": "0.00639",
      "percentile": "0.4889"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "n/a",
                "vendor": "n/a",
                "versions": [
                  {
                    "status": "affected",
                    "version": "n/a"
                  }
                ]
              }
            ],
            "source": "cve@mitre.org"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:totolink:a950rg_firmware:4.1.2cu.5204_b20210112:*:*:*:*:*:*:*",
                    "matchCriteriaId": "730932A4-0583-43BA-995A-EFCE271B9BA6",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:totolink:a950rg:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2F20C691-11F3-4882-89C7-500C097C0938",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A buffer overflow vulnerability exists in TOTOLINK A950RG V4.1.2cu.5204_B20210112. The issue resides in the setRadvdCfg interface of the /lib/cste_modules/ipv6.so module. The function fails to properly validate the length of the user-controlled radvdinterfacename parameter, allowing remote attackers to trigger a stack buffer overflow."
          },
          {
            "lang": "es",
            "value": "Una vulnerabilidad de desbordamiento de b\u00fafer existe en TOTOLINK A950RG V4.1.2cu.5204_B20210112. El problema reside en la interfaz setRadvdCfg del m\u00f3dulo /lib/cste_modules/ipv6.so. La funci\u00f3n no valida correctamente la longitud del par\u00e1metro radvdinterfacename controlado por el usuario, permitiendo a atacantes remotos activar un desbordamiento de b\u00fafer de pila."
          }
        ],
        "id": "CVE-2025-67188",
        "lastModified": "2026-06-17T09:57:30.807",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2025-67188",
                "options": [
                  {
                    "exploitation": "poc"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-05T14:32:46.803630Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-02-03T18:16:16.280",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/ToTolink/A950RG/5024-ipv6-setRadvdCfg-radvdinterfacename-buffer.md"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-120"
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-02-04T03:15:24+00:00",
      "cve": "CVE-2025-67188",
      "id": "CVE-2025-67188",
      "initial_release_date": "2025-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2025-67188",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-67188.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-67188",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-05T14:32:46.803630Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-120",
                    "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-05T14:33:40.411Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A buffer overflow vulnerability exists in TOTOLINK A950RG V4.1.2cu.5204_B20210112. The issue resides in the setRadvdCfg interface of the /lib/cste_modules/ipv6.so module. The function fails to properly validate the length of the user-controlled radvdinterfacename parameter, allowing remote attackers to trigger a stack buffer overflow."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-03T17:40:19.303Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/ToTolink/A950RG/5024-ipv6-setRadvdCfg-radvdinterfacename-buffer.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-67188",
        "datePublished": "2026-02-03T00:00:00.000Z",
        "dateReserved": "2025-12-08T00:00:00.000Z",
        "dateUpdated": "2026-02-05T14:33:55.035Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…