CVE-2026-11730 (GCVE-0-2026-11730)
Vulnerability from cvelistv5 – Published: 2026-10-13 14:38 – Updated: 2026-10-19 19:02- CWE-335 - Incorrect usage of seeds in Pseudo-Random number generator (PRNG)
| URL | Tags |
|---|---|
| https://www.netgear.com/support/product/ex3700 | productpatch |
| https://www.netgear.com/support/product/ex6120 | productpatch |
| https://kb.netgear.com/000070958/October-2026-NET… | vendor-advisorypatch |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11730",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-19T19:02:40.872210Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-19T19:02:53.835Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EX3700",
"vendor": "NETGEAR",
"versions": [
{
"lessThan": "V1.0.0.102",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EX6120",
"vendor": "NETGEAR",
"versions": [
{
"lessThan": "V1.0.1.74",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "KDec5ae262-35b5-41c5-9bc1-91ad34145487 and Austin Turecek (Collaborator)"
}
],
"datePublic": "2026-10-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eInsufficient session randomness vulnerability in the listed NETGEAR Extender models allows a network-adjacent attacker having network access (such as WiFi credentials) to predict valid session identifiers and hijack an authenticated administrator session on the web management portal.\u0026nbsp;\u003c/p\u003e"
}
],
"value": "Insufficient session randomness vulnerability in the listed NETGEAR Extender models allows a network-adjacent attacker having network access (such as WiFi credentials) to predict valid session identifiers and hijack an authenticated administrator session on the web management portal."
}
],
"impacts": [
{
"capecId": "CAPEC-593",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-593 Session Hijacking"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 2.1,
"baseSeverity": "LOW",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "LOW",
"providerUrgency": "AMBER",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N/E:U/V:D/RE:L/U:Amber",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "LOW"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-335",
"description": "CWE-335 Incorrect usage of seeds in Pseudo-Random number generator (PRNG)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-16T13:52:30.789Z",
"orgId": "a2826606-91e7-4eb6-899e-8484bd4575d5",
"shortName": "NETGEAR"
},
"references": [
{
"tags": [
"product",
"patch"
],
"url": "https://www.netgear.com/support/product/ex3700"
},
{
"tags": [
"product",
"patch"
],
"url": "https://www.netgear.com/support/product/ex6120"
},
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://kb.netgear.com/000070958/October-2026-NETGEAR-Security-Advisory"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eDevices with automatic updates enabled may already have this patch applied. If not, please check the firmware version and update it to the latest. Fixed in:\u003c/p\u003e\u003ctable style=\"border-collapse:collapse;\"\u003e\u003cthead\u003e\u003ctr\u003e\u003cth style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003eProduct\u003c/th\u003e\u003cth style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003eFixed Version\u003c/th\u003e\u003c/tr\u003e\u003c/thead\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003e\u003cb\u003eEX3700 (EoS)\u003c/b\u003e AC750 WiFi Range Extender Essentials Edition\u003c/td\u003e\u003ctd style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003e\u003ca href=\"https://www.netgear.com/support/product/ex3700\"\u003eV1.0.0.102\u003c/a\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003e\u003cb\u003eEX6120\u003c/b\u003e AC1200 Dual Band WiFi Range Extender\u003c/td\u003e\u003ctd style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003e\u003ca href=\"https://www.netgear.com/support/product/ex6120\"\u003eV1.0.1.74\u003c/a\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003cp\u003eModels marked (EoS) have reached End-of-Support phase, and no security updates are planned. NETGEAR strongly recommends that you retire these devices and upgrade to a newer NETGEAR device for continued security support.\u003c/p\u003e"
}
],
"value": "Devices with automatic updates enabled may already have this patch applied. If not, please check the firmware version and update it to the latest. Fixed in:\n\nProductFixed VersionEX3700 (EoS) AC750 WiFi Range Extender Essentials Edition V1.0.0.102 https://www.netgear.com/support/product/ex3700 EX6120 AC1200 Dual Band WiFi Range Extender V1.0.1.74 https://www.netgear.com/support/product/ex6120 \n\nModels marked (EoS) have reached End-of-Support phase, and no security updates are planned. NETGEAR strongly recommends that you retire these devices and upgrade to a newer NETGEAR device for continued security support."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Insufficient session randomness vulnerability exists in certain NETGEAR EX Series Models",
"x_generator": {
"engine": "Vulnogram 1.0.3"
}
}
},
"cveMetadata": {
"assignerOrgId": "a2826606-91e7-4eb6-899e-8484bd4575d5",
"assignerShortName": "NETGEAR",
"cveId": "CVE-2026-11730",
"datePublished": "2026-10-13T14:38:16.110Z",
"dateReserved": "2026-06-09T02:46:38.130Z",
"dateUpdated": "2026-10-19T19:02:53.835Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-11730",
"date": "2026-11-11",
"epss": "0.00185",
"percentile": "0.08246"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "EX3700",
"vendor": "NETGEAR",
"versions": [
{
"lessThan": "V1.0.0.102",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EX6120",
"vendor": "NETGEAR",
"versions": [
{
"lessThan": "V1.0.1.74",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "a2826606-91e7-4eb6-899e-8484bd4575d5"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Insufficient session randomness vulnerability in the listed NETGEAR Extender models allows a network-adjacent attacker having network access (such as WiFi credentials) to predict valid session identifiers and hijack an authenticated administrator session on the web management portal."
}
],
"id": "CVE-2026-11730",
"lastModified": "2026-10-19T20:17:55.943",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 4.2,
"source": "a2826606-91e7-4eb6-899e-8484bd4575d5",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 2.1,
"baseSeverity": "LOW",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "UNREPORTED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "AMBER",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:D/RE:L/U:Amber",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "LOW"
},
"source": "a2826606-91e7-4eb6-899e-8484bd4575d5",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-11730",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-19T19:02:40.872210Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-10-13T15:17:43.340",
"references": [
{
"source": "a2826606-91e7-4eb6-899e-8484bd4575d5",
"url": "https://kb.netgear.com/000070958/October-2026-NETGEAR-Security-Advisory"
},
{
"source": "a2826606-91e7-4eb6-899e-8484bd4575d5",
"url": "https://www.netgear.com/support/product/ex3700"
},
{
"source": "a2826606-91e7-4eb6-899e-8484bd4575d5",
"url": "https://www.netgear.com/support/product/ex6120"
}
],
"sourceIdentifier": "a2826606-91e7-4eb6-899e-8484bd4575d5",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-335"
}
],
"source": "a2826606-91e7-4eb6-899e-8484bd4575d5",
"type": "Secondary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11730",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-19T19:02:40.872210Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-19T19:02:47.530Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EX3700",
"vendor": "NETGEAR",
"versions": [
{
"lessThan": "V1.0.0.102",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EX6120",
"vendor": "NETGEAR",
"versions": [
{
"lessThan": "V1.0.1.74",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "KDec5ae262-35b5-41c5-9bc1-91ad34145487 and Austin Turecek (Collaborator)"
}
],
"datePublic": "2026-10-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eInsufficient session randomness vulnerability in the listed NETGEAR Extender models allows a network-adjacent attacker having network access (such as WiFi credentials) to predict valid session identifiers and hijack an authenticated administrator session on the web management portal.\u0026nbsp;\u003c/p\u003e"
}
],
"value": "Insufficient session randomness vulnerability in the listed NETGEAR Extender models allows a network-adjacent attacker having network access (such as WiFi credentials) to predict valid session identifiers and hijack an authenticated administrator session on the web management portal."
}
],
"impacts": [
{
"capecId": "CAPEC-593",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-593 Session Hijacking"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 2.1,
"baseSeverity": "LOW",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "LOW",
"providerUrgency": "AMBER",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N/E:U/V:D/RE:L/U:Amber",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "LOW"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-335",
"description": "CWE-335 Incorrect usage of seeds in Pseudo-Random number generator (PRNG)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-16T13:52:30.789Z",
"orgId": "a2826606-91e7-4eb6-899e-8484bd4575d5",
"shortName": "NETGEAR"
},
"references": [
{
"tags": [
"product",
"patch"
],
"url": "https://www.netgear.com/support/product/ex3700"
},
{
"tags": [
"product",
"patch"
],
"url": "https://www.netgear.com/support/product/ex6120"
},
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://kb.netgear.com/000070958/October-2026-NETGEAR-Security-Advisory"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eDevices with automatic updates enabled may already have this patch applied. If not, please check the firmware version and update it to the latest. Fixed in:\u003c/p\u003e\u003ctable style=\"border-collapse:collapse;\"\u003e\u003cthead\u003e\u003ctr\u003e\u003cth style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003eProduct\u003c/th\u003e\u003cth style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003eFixed Version\u003c/th\u003e\u003c/tr\u003e\u003c/thead\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003e\u003cb\u003eEX3700 (EoS)\u003c/b\u003e AC750 WiFi Range Extender Essentials Edition\u003c/td\u003e\u003ctd style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003e\u003ca href=\"https://www.netgear.com/support/product/ex3700\"\u003eV1.0.0.102\u003c/a\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003e\u003cb\u003eEX6120\u003c/b\u003e AC1200 Dual Band WiFi Range Extender\u003c/td\u003e\u003ctd style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003e\u003ca href=\"https://www.netgear.com/support/product/ex6120\"\u003eV1.0.1.74\u003c/a\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003cp\u003eModels marked (EoS) have reached End-of-Support phase, and no security updates are planned. NETGEAR strongly recommends that you retire these devices and upgrade to a newer NETGEAR device for continued security support.\u003c/p\u003e"
}
],
"value": "Devices with automatic updates enabled may already have this patch applied. If not, please check the firmware version and update it to the latest. Fixed in:\n\nProductFixed VersionEX3700 (EoS) AC750 WiFi Range Extender Essentials Edition V1.0.0.102 https://www.netgear.com/support/product/ex3700 EX6120 AC1200 Dual Band WiFi Range Extender V1.0.1.74 https://www.netgear.com/support/product/ex6120 \n\nModels marked (EoS) have reached End-of-Support phase, and no security updates are planned. NETGEAR strongly recommends that you retire these devices and upgrade to a newer NETGEAR device for continued security support."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Insufficient session randomness vulnerability exists in certain NETGEAR EX Series Models",
"x_generator": {
"engine": "Vulnogram 1.0.3"
}
}
},
"cveMetadata": {
"assignerOrgId": "a2826606-91e7-4eb6-899e-8484bd4575d5",
"assignerShortName": "NETGEAR",
"cveId": "CVE-2026-11730",
"datePublished": "2026-10-13T14:38:16.110Z",
"dateReserved": "2026-06-09T02:46:38.130Z",
"dateUpdated": "2026-10-19T19:02:53.835Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.