CVE-2026-129502 (GCVE-0-2026-129502)
Vulnerability from cvelistv5 – Published: 2026-11-19 18:20 – Updated: 2026-11-19 18:20- CWE-248 - Uncaught Exception
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| @fastify/http-proxy | @fastify/http-proxy |
Affected:
9.4.0 , < 11.6.10
(semver)
Unaffected: 11.6.10 (semver) |
guessed |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"packageURL": "pkg:npm/@fastify/http-proxy",
"product": "@fastify/http-proxy",
"vendor": "@fastify/http-proxy",
"versions": [
{
"lessThan": "11.6.10",
"status": "affected",
"version": "9.4.0",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "11.6.10",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "apflffhtm"
},
{
"lang": "en",
"type": "remediation developer",
"value": "mcollina"
},
{
"lang": "en",
"type": "remediation developer",
"value": "UlisesGascon"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "@fastify/http-proxy is a Fastify plugin that proxies HTTP and WebSocket traffic to an upstream server. In versions from 9.4.0 up to but not including 11.6.10, when the plugin is registered with websocket support enabled, a WebSocket upgrade request whose path carries a URL fragment is matched by the router and answered with a successful upgrade before the upstream link is created. Building the upstream target then throws, the error is only logged, and the accepted client socket is left open with no error listener, so the next frame the client sends becomes an unhandled error and terminates the Node.js process. A request target that is not a valid URL reference reaching a parameterized prefix triggers the same path. A single unauthenticated upgrade request followed by one frame is enough to crash the server, and it can be repeated to keep the process down. The issue is fixed in @fastify/http-proxy 11.6.10, and users should upgrade to 11.6.10 or later."
}
],
"value": "@fastify/http-proxy is a Fastify plugin that proxies HTTP and WebSocket traffic to an upstream server. In versions from 9.4.0 up to but not including 11.6.10, when the plugin is registered with websocket support enabled, a WebSocket upgrade request whose path carries a URL fragment is matched by the router and answered with a successful upgrade before the upstream link is created. Building the upstream target then throws, the error is only logged, and the accepted client socket is left open with no error listener, so the next frame the client sends becomes an unhandled error and terminates the Node.js process. A request target that is not a valid URL reference reaching a parameterized prefix triggers the same path. A single unauthenticated upgrade request followed by one frame is enough to crash the server, and it can be repeated to keep the process down. The issue is fixed in @fastify/http-proxy 11.6.10, and users should upgrade to 11.6.10 or later."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-19T18:20:55.293Z",
"orgId": "ce714d77-add3-4f53-aff5-83d477b104bb",
"shortName": "openjs"
},
"references": [
{
"url": "https://github.com/fastify/fastify-http-proxy/security/advisories/GHSA-29w6-p7r8-xmf9"
},
{
"url": "https://cna.openjsf.org/security-advisories.html"
}
],
"title": "@fastify/http-proxy vulnerable to Denial of Service via a URL fragment in a WebSocket upgrade",
"x_generator": {
"engine": "cve-kit 1.0.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "ce714d77-add3-4f53-aff5-83d477b104bb",
"assignerShortName": "openjs",
"cveId": "CVE-2026-129502",
"datePublished": "2026-11-19T18:20:55.293Z",
"dateReserved": "2026-11-15T18:13:19.051Z",
"dateUpdated": "2026-11-19T18:20:55.293Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"packageURL": "pkg:npm/@fastify/http-proxy",
"product": "@fastify/http-proxy",
"vendor": "@fastify/http-proxy",
"versions": [
{
"lessThan": "11.6.10",
"status": "affected",
"version": "9.4.0",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "11.6.10",
"versionType": "semver"
}
]
}
],
"source": "ce714d77-add3-4f53-aff5-83d477b104bb"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "@fastify/http-proxy is a Fastify plugin that proxies HTTP and WebSocket traffic to an upstream server. In versions from 9.4.0 up to but not including 11.6.10, when the plugin is registered with websocket support enabled, a WebSocket upgrade request whose path carries a URL fragment is matched by the router and answered with a successful upgrade before the upstream link is created. Building the upstream target then throws, the error is only logged, and the accepted client socket is left open with no error listener, so the next frame the client sends becomes an unhandled error and terminates the Node.js process. A request target that is not a valid URL reference reaching a parameterized prefix triggers the same path. A single unauthenticated upgrade request followed by one frame is enough to crash the server, and it can be repeated to keep the process down. The issue is fixed in @fastify/http-proxy 11.6.10, and users should upgrade to 11.6.10 or later."
}
],
"id": "CVE-2026-129502",
"lastModified": "2026-11-19T19:17:25.407",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "ce714d77-add3-4f53-aff5-83d477b104bb",
"type": "Secondary"
}
]
},
"published": "2026-11-19T19:17:25.407",
"references": [
{
"source": "ce714d77-add3-4f53-aff5-83d477b104bb",
"url": "https://cna.openjsf.org/security-advisories.html"
},
{
"source": "ce714d77-add3-4f53-aff5-83d477b104bb",
"url": "https://github.com/fastify/fastify-http-proxy/security/advisories/GHSA-29w6-p7r8-xmf9"
}
],
"sourceIdentifier": "ce714d77-add3-4f53-aff5-83d477b104bb",
"vulnStatus": "Received",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-248"
}
],
"source": "ce714d77-add3-4f53-aff5-83d477b104bb",
"type": "Secondary"
}
]
}
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.