CVE-2026-1907 (GCVE-0-2026-1907)

Vulnerability from cvelistv5 – Published: 2026-10-12 08:38 – Updated: 2026-10-12 08:38
VLAI
Title
SQL Injection in Clustering Communication (Hybrid Mode)
Summary
A SQL Injection (SQLi) affects the Kong Gateway (Enterprise and Open Source) clustering communication logic when operating in Hybrid Mode. The issue can be triggered by sending specially crafted RPC requests to the Control Plane (CP), leading to potential unauthorized database access. Leveraging the issue requires network access to the Control Plane’s clustering port and a valid client certificate and key.
CWE
  • CWE-89 - Improper neutralization of special elements used in an SQL command ('SQL injection')
Assigner
Kong CNA under the mitre root
CNA scorecard B 85/100 over 17 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
Kong Kong Enterprise Gateway Affected: 3.10.0.0 , < 3.10.0.9 (kong ee gateway 3.10)
Affected: 3.11.0.0 , < 3.11.0.8 (kong ee gateway 3.11)
Affected: 3.12.0.0 , < 3.12.0.4 (kong ee gateway 3.12)
Affected: 3.13.0.0 , < 3.13.0.2 (kong ee gateway 3.13)
guessed Create a notification for this product.
Kong Kong Gateway Affected: 0 , < 3.9.4 (Kong Gateway 3.4)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "packageName": "kong-ee",
          "platforms": [
            "Linux"
          ],
          "product": "Kong Enterprise Gateway",
          "vendor": "Kong",
          "versions": [
            {
              "lessThan": "3.10.0.9",
              "status": "affected",
              "version": "3.10.0.0",
              "versionType": "kong ee gateway 3.10"
            },
            {
              "lessThan": "3.11.0.8",
              "status": "affected",
              "version": "3.11.0.0",
              "versionType": "kong ee gateway 3.11"
            },
            {
              "lessThan": "3.12.0.4",
              "status": "affected",
              "version": "3.12.0.0",
              "versionType": "kong ee gateway 3.12"
            },
            {
              "lessThan": "3.13.0.2",
              "status": "affected",
              "version": "3.13.0.0",
              "versionType": "kong ee gateway 3.13"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "packageName": "kong",
          "product": "Kong Gateway",
          "repo": "https://github.com/Kong/kong",
          "vendor": "Kong",
          "versions": [
            {
              "lessThan": "3.9.4",
              "status": "affected",
              "version": "0",
              "versionType": "Kong Gateway 3.4"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "four0four from ZeroVuln Labs"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cpre\u003eA SQL Injection (SQLi) affects the Kong Gateway (Enterprise and Open Source) clustering communication logic when operating in Hybrid Mode. The issue can be triggered by sending specially crafted RPC requests to the Control Plane (CP), leading to potential unauthorized database access. Leveraging the issue requires network access to the Control Plane\u2019s clustering port and a valid client certificate and key.\u003cbr\u003e\u003c/pre\u003e"
            }
          ],
          "value": "A SQL Injection (SQLi) affects the Kong Gateway (Enterprise and Open Source) clustering communication logic when operating in Hybrid Mode. The issue can be triggered by sending specially crafted RPC requests to the Control Plane (CP), leading to potential unauthorized database access. Leveraging the issue requires network access to the Control Plane\u2019s clustering port and a valid client certificate and key."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-66",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-66 SQL Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper neutralization of special elements used in an SQL command (\u0027SQL injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-12T08:38:54.485Z",
        "orgId": "02762ae7-200e-4b20-9b2b-a77d5b8fc4cb",
        "shortName": "Kong"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://developer.konghq.com/gateway/changelog/#3-13-0-2"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://github.com/Kong/kong/security/advisories/GHSA-vwxq-38j7-x48j"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "SQL Injection in Clustering Communication (Hybrid Mode)",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "02762ae7-200e-4b20-9b2b-a77d5b8fc4cb",
    "assignerShortName": "Kong",
    "cveId": "CVE-2026-1907",
    "datePublished": "2026-10-12T08:38:54.485Z",
    "dateReserved": "2026-02-04T15:21:03.888Z",
    "dateUpdated": "2026-10-12T08:38:54.485Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-1907",
      "date": "2026-10-12",
      "epss": "0.00131",
      "percentile": "0.02323"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "packageName": "kong-ee",
                "platforms": [
                  "Linux"
                ],
                "product": "Kong Enterprise Gateway",
                "vendor": "Kong",
                "versions": [
                  {
                    "lessThan": "3.10.0.9",
                    "status": "affected",
                    "version": "3.10.0.0",
                    "versionType": "kong ee gateway 3.10"
                  },
                  {
                    "lessThan": "3.11.0.8",
                    "status": "affected",
                    "version": "3.11.0.0",
                    "versionType": "kong ee gateway 3.11"
                  },
                  {
                    "lessThan": "3.12.0.4",
                    "status": "affected",
                    "version": "3.12.0.0",
                    "versionType": "kong ee gateway 3.12"
                  },
                  {
                    "lessThan": "3.13.0.2",
                    "status": "affected",
                    "version": "3.13.0.0",
                    "versionType": "kong ee gateway 3.13"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "packageName": "kong",
                "product": "Kong Gateway",
                "repo": "https://github.com/Kong/kong",
                "vendor": "Kong",
                "versions": [
                  {
                    "lessThan": "3.9.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "Kong Gateway 3.4"
                  }
                ]
              }
            ],
            "source": "02762ae7-200e-4b20-9b2b-a77d5b8fc4cb"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A SQL Injection (SQLi) affects the Kong Gateway (Enterprise and Open Source) clustering communication logic when operating in Hybrid Mode. The issue can be triggered by sending specially crafted RPC requests to the Control Plane (CP), leading to potential unauthorized database access. Leveraging the issue requires network access to the Control Plane\u2019s clustering port and a valid client certificate and key."
          }
        ],
        "id": "CVE-2026-1907",
        "lastModified": "2026-10-12T09:16:43.683",
        "metrics": {
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "ADJACENT",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "02762ae7-200e-4b20-9b2b-a77d5b8fc4cb",
              "type": "Secondary"
            }
          ]
        },
        "published": "2026-10-12T09:16:43.683",
        "references": [
          {
            "source": "02762ae7-200e-4b20-9b2b-a77d5b8fc4cb",
            "url": "https://developer.konghq.com/gateway/changelog/#3-13-0-2"
          },
          {
            "source": "02762ae7-200e-4b20-9b2b-a77d5b8fc4cb",
            "url": "https://github.com/Kong/kong/security/advisories/GHSA-vwxq-38j7-x48j"
          }
        ],
        "sourceIdentifier": "02762ae7-200e-4b20-9b2b-a77d5b8fc4cb",
        "vulnStatus": "Received",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-89"
              }
            ],
            "source": "02762ae7-200e-4b20-9b2b-a77d5b8fc4cb",
            "type": "Secondary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.