CVE-2026-87672 (GCVE-0-2026-87672)

Vulnerability from cvelistv5 – Published: 2026-10-08 02:55 – Updated: 2026-10-08 13:14
VLAI
Summary
An information disclosure vulnerability exists in the SupportLink diagnostic collection utilities of Brocade Fabric OS versions before 10.0.1. When SupportLink is configured to use an authenticated HTTP proxy, the system stores the full proxy URL. Anyone with access to the diagnostic support bundle, such as support personnel or users with access to file shares where support bundles are stored, can extract these cleartext proxy credentials.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-08 13:14 UTC
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
brocade CNA under the mitre root
CNA scorecard B 75/100 over 70 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
Brocade Fabric OS Affected: 0 , < 10.0.1 (Brocade FabricOS)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-87672",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-08T13:14:06.821604Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-08T13:14:25.879Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "lessThan": "10.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "Brocade FabricOS"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn information disclosure vulnerability exists in the SupportLink diagnostic collection utilities of Brocade Fabric OS versions before 10.0.1. When SupportLink is configured to use an authenticated HTTP proxy, the system stores the full proxy URL. Anyone with access to the diagnostic support bundle, such as support personnel or users with access to file shares where support bundles are stored, can extract these cleartext proxy credentials.\u003c/p\u003e"
            }
          ],
          "value": "An information disclosure vulnerability exists in the SupportLink diagnostic collection utilities of Brocade Fabric OS versions before 10.0.1. When SupportLink is configured to use an authenticated HTTP proxy, the system stores the full proxy URL. Anyone with access to the diagnostic support bundle, such as support personnel or users with access to file shares where support bundles are stored, can extract these cleartext proxy credentials."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-08T02:55:58.519Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/39142"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003eSecurity update is provided in Brocade Fabric OS 10.0.1\u003c/div\u003e\u003cdiv\u003e\u003c/div\u003e"
            }
          ],
          "value": "Security update is provided in Brocade Fabric OS 10.0.1"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2026-87672",
    "datePublished": "2026-10-08T02:55:58.519Z",
    "dateReserved": "2026-09-08T22:51:12.166Z",
    "dateUpdated": "2026-10-08T13:14:25.879Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-87672",
      "date": "2026-10-09",
      "epss": "0.00114",
      "percentile": "0.01373"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "Fabric OS",
                "vendor": "Brocade",
                "versions": [
                  {
                    "lessThan": "10.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "Brocade FabricOS"
                  }
                ]
              }
            ],
            "source": "sirt@brocade.com"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An information disclosure vulnerability exists in the SupportLink diagnostic collection utilities of Brocade Fabric OS versions before 10.0.1. When SupportLink is configured to use an authenticated HTTP proxy, the system stores the full proxy URL. Anyone with access to the diagnostic support bundle, such as support personnel or users with access to file shares where support bundles are stored, can extract these cleartext proxy credentials."
          }
        ],
        "id": "CVE-2026-87672",
        "lastModified": "2026-10-08T20:08:45.857",
        "metrics": {
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "sirt@brocade.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-87672",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-08T13:14:06.821604Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-10-08T03:16:36.810",
        "references": [
          {
            "source": "sirt@brocade.com",
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/39142"
          }
        ],
        "sourceIdentifier": "sirt@brocade.com",
        "vulnStatus": "Awaiting Analysis",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-532"
              }
            ],
            "source": "sirt@brocade.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-87672",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-08T13:14:06.821604Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-08T13:14:15.347Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Fabric OS",
              "vendor": "Brocade",
              "versions": [
                {
                  "lessThan": "10.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "Brocade FabricOS"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAn information disclosure vulnerability exists in the SupportLink diagnostic collection utilities of Brocade Fabric OS versions before 10.0.1. When SupportLink is configured to use an authenticated HTTP proxy, the system stores the full proxy URL. Anyone with access to the diagnostic support bundle, such as support personnel or users with access to file shares where support bundles are stored, can extract these cleartext proxy credentials.\u003c/p\u003e"
                }
              ],
              "value": "An information disclosure vulnerability exists in the SupportLink diagnostic collection utilities of Brocade Fabric OS versions before 10.0.1. When SupportLink is configured to use an authenticated HTTP proxy, the system stores the full proxy URL. Anyone with access to the diagnostic support bundle, such as support personnel or users with access to file shares where support bundles are stored, can extract these cleartext proxy credentials."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-37",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-532",
                  "description": "CWE-532: Insertion of Sensitive Information into Log File",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-08T02:55:58.519Z",
            "orgId": "87b297d7-335e-4844-9551-11b97995a791",
            "shortName": "brocade"
          },
          "references": [
            {
              "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/39142"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003eSecurity update is provided in Brocade Fabric OS 10.0.1\u003c/div\u003e\u003cdiv\u003e\u003c/div\u003e"
                }
              ],
              "value": "Security update is provided in Brocade Fabric OS 10.0.1"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
        "assignerShortName": "brocade",
        "cveId": "CVE-2026-87672",
        "datePublished": "2026-10-08T02:55:58.519Z",
        "dateReserved": "2026-09-08T22:51:12.166Z",
        "dateUpdated": "2026-10-08T13:14:25.879Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…