ICSA-18-144-01
Vulnerability from csaf_cisa
Published
2018-05-24 00:00
Modified
2018-05-24 00:00
Summary
Schneider Electric Floating License Manager
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could cause a denial of service, allow arbitrary execution of code with system level privileges, or send users to arbitrary websites.
Critical infrastructure sectors
Commercial Facilities, Energy, Food and Agriculture, Government Facilities, Transportation Systems, Water and Wastewater Systems
Countries/areas deployed
Worldwide
Company headquarters location
France
Recommended Practices
NCCIC recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:
Recommended Practices
NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Exploitability
No known public exploits specifically target these vulnerabilities.
{ "document": { "acknowledgments": [ { "organization": "Schneider Electric", "summary": "reporting these vulnerabilities to NCCIC" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could cause a denial of service, allow arbitrary execution of code with system level privileges, or send users to arbitrary websites.", "title": "Risk evaluation" }, { "category": "other", "text": "Commercial Facilities, Energy, Food and Agriculture, Government Facilities, Transportation Systems, Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "France", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-18-144-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsa-18-144-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-18-144-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-144-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-144-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" } ], "title": "Schneider Electric Floating License Manager", "tracking": { "current_release_date": "2018-05-24T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-18-144-01", "initial_release_date": "2018-05-24T00:00:00.000000Z", "revision_history": [ { "date": "2018-05-24T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-18-144-01 Schneider Electric Floating License Manager" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 3.0", "product": { "name": "EcoStruxure Modicon Builder: V3.0 and prior", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "EcoStruxure Modicon Builder" }, { "branches": [ { "category": "product_version", "name": "8.2 (Standard DC HC Editions)", "product": { "name": "EcoStruxure Power Monitoring Expert: 8.2 (Standard DC HC Editions)", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "EcoStruxure Power Monitoring Expert" }, { "branches": [ { "category": "product_version", "name": "7.30 | 7.40", "product": { "name": "SCADA Expert Vijeo Citect / CitectSCADA: Version 7.30 7.40", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "SCADA Expert Vijeo Citect / CitectSCADA" }, { "branches": [ { "category": "product_version", "name": "1.x (formerly Power Manager)", "product": { "name": "Energy Expert: 1.x (formerly Power Manager)", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Energy Expert" }, { "branches": [ { "category": "product_version", "name": "8.x (formerly PowerSCADA Expert) (Only with Advanced Reports and Dashboards Module)", "product": { "name": "EcoStruxure Power SCADA Operations: 8.x (formerly PowerSCADA Expert) (Only with Advanced Reports and Dashboards Module)", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "EcoStruxure Power SCADA Operations" }, { "branches": [ { "category": "product_version", "name": "7.2.x", "product": { "name": "StruxureWare Power Monitoring Expert: 7.2.x", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "StruxureWare Power Monitoring Expert" }, { "branches": [ { "category": "product_version", "name": "4.40 | 4.50", "product": { "name": "Vijeo Historian/CitectHistorian: Version 4.40 4.50", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "Vijeo Historian/CitectHistorian" }, { "branches": [ { "category": "product_version", "name": "8.1 (Standard DC HC Editions)", "product": { "name": "StruxureWare Power Monitoring Expert: 8.1 (Standard DC HC Editions)", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "StruxureWare Power Monitoring Expert" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=8.1 (Standard DC HC Editions)", "product": { "name": "PlantStruxure PES: V4.3 SP1 and prior", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "PlantStruxure PES" }, { "branches": [ { "category": "product_version", "name": "8.0 (Standard DC HC Buildings Editions)", "product": { "name": "StruxureWare Power Monitoring Expert: 8.0 (Standard DC HC Buildings Editions)", "product_id": "CSAFPID-00010" } } ], "category": "product_name", "name": "StruxureWare Power Monitoring Expert" }, { "branches": [ { "category": "product_version", "name": "2015 | 2016", "product": { "name": "CitectSCADA: Version 2015 2016", "product_id": "CSAFPID-00011" } } ], "category": "product_name", "name": "CitectSCADA" }, { "branches": [ { "category": "product_version", "name": "2016", "product": { "name": "CitectHistorian: Version 2016", "product_id": "CSAFPID-00012" } } ], "category": "product_name", "name": "CitectHistorian" } ], "category": "vendor", "name": "Schneider Electric Software, LLC" } ] }, "vulnerabilities": [ { "cve": "CVE-2016-2177", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "OpenSSL incorrectly uses pointer arithmetic for heap-buffer boundary checks, which may allow denial of service attacks or other unspecified behavior.CVE-2016-2177 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-2177" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Schneider Electric recommends that users of affected Citect and PlantStruxure products download and install the new version of the software", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://www.citect.schneider-electric.com/documents/downloads/Floating_License_Manager_v2.1.0.0.zip" }, { "category": "mitigation", "details": "Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://partner.schneider-electric.com/partners/Menu/MyPartnership" }, { "category": "mitigation", "details": "StructureWare 7.2.x users should upgrade to Version 7.2.2 and apply the floating licensing manager (FLM) patch", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://schneider-electric.box.com/s/n2fh1ym594pqvl87kf0zjsigamuryrje" }, { "category": "mitigation", "details": "EcoStruxure/StruxureWare Power Monitoring Expert and Power SCADA Operations users need to upgrade to Version 8.2. ", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://schneider-electric.box.com/s/kkdikodcksjj1dznqy68ko0j28wct7vb" }, { "category": "mitigation", "details": "Schneider Electric has also released security notifications which contain further details and upgrade", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9134-vulnerabilities-within-schneider-electric-floating-license-manager" }, { "category": "mitigation", "details": "Schneider Electric has also released security notifications which contain further details and upgrade ", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-137-01/" }, { "category": "mitigation", "details": "Schneider Electric has also released security notifications which contain further details and upgrade ", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-144-01/" }, { "category": "mitigation", "details": "Schneider Electric has also released security notifications which contain further details and upgrade", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-046-01/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ] } ] }, { "cve": "CVE-2016-10395", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "This vulnerability can be exploited to cause an out-of-bounds memory read access, which may allow remote code execution with system privileges.CVE-2016-10395 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-10395" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Schneider Electric recommends that users of affected Citect and PlantStruxure products download and install the new version of the software", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://www.citect.schneider-electric.com/documents/downloads/Floating_License_Manager_v2.1.0.0.zip" }, { "category": "mitigation", "details": "Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://partner.schneider-electric.com/partners/Menu/MyPartnership" }, { "category": "mitigation", "details": "StructureWare 7.2.x users should upgrade to Version 7.2.2 and apply the floating licensing manager (FLM) patch", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://schneider-electric.box.com/s/n2fh1ym594pqvl87kf0zjsigamuryrje" }, { "category": "mitigation", "details": "EcoStruxure/StruxureWare Power Monitoring Expert and Power SCADA Operations users need to upgrade to Version 8.2. ", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://schneider-electric.box.com/s/kkdikodcksjj1dznqy68ko0j28wct7vb" }, { "category": "mitigation", "details": "Schneider Electric has also released security notifications which contain further details and upgrade", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9134-vulnerabilities-within-schneider-electric-floating-license-manager" }, { "category": "mitigation", "details": "Schneider Electric has also released security notifications which contain further details and upgrade ", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-137-01/" }, { "category": "mitigation", "details": "Schneider Electric has also released security notifications which contain further details and upgrade ", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-144-01/" }, { "category": "mitigation", "details": "Schneider Electric has also released security notifications which contain further details and upgrade", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-046-01/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ] } ] }, { "cve": "CVE-2017-5571", "cwe": { "id": "CWE-601", "name": "URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)" }, "notes": [ { "category": "summary", "text": "An open redirect vulnerability has been identified, which may allow remote attackers to redirect users to arbitrary websites for phishing attacks.CVE-2017-5571 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-5571" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Schneider Electric recommends that users of affected Citect and PlantStruxure products download and install the new version of the software", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://www.citect.schneider-electric.com/documents/downloads/Floating_License_Manager_v2.1.0.0.zip" }, { "category": "mitigation", "details": "Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://partner.schneider-electric.com/partners/Menu/MyPartnership" }, { "category": "mitigation", "details": "StructureWare 7.2.x users should upgrade to Version 7.2.2 and apply the floating licensing manager (FLM) patch", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://schneider-electric.box.com/s/n2fh1ym594pqvl87kf0zjsigamuryrje" }, { "category": "mitigation", "details": "EcoStruxure/StruxureWare Power Monitoring Expert and Power SCADA Operations users need to upgrade to Version 8.2. ", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://schneider-electric.box.com/s/kkdikodcksjj1dznqy68ko0j28wct7vb" }, { "category": "mitigation", "details": "Schneider Electric has also released security notifications which contain further details and upgrade", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9134-vulnerabilities-within-schneider-electric-floating-license-manager" }, { "category": "mitigation", "details": "Schneider Electric has also released security notifications which contain further details and upgrade ", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-137-01/" }, { "category": "mitigation", "details": "Schneider Electric has also released security notifications which contain further details and upgrade ", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-144-01/" }, { "category": "mitigation", "details": "Schneider Electric has also released security notifications which contain further details and upgrade", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-046-01/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012" ] } ] } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.