ICSA-22-132-06
Vulnerability from csaf_cisa
Published
2022-05-12 00:00
Modified
2022-06-16 00:00
Summary
Siemens SIMATIC WinCC
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of this vulnerability could allow authenticated attackers to escape the kiosk mode.
Critical infrastructure sectors
Multiple Sectors
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Recommended Practices
CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open unsolicited attachments in email messages; Refer to Recognizing and Avoiding Email Scams (https://us-cert.cisa.gov/sites/default/files/publications/emailscams_0905.pdf) for more information on avoiding email scams; Refer to Avoiding Social Engineering and Phishing Attacks (https://us-cert.cisa.gov/ncas/tips/ST04-014) for more information on social engineering attacks.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Exploitability
No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting this vulnerability to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow authenticated attackers to escape the kiosk mode.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open unsolicited attachments in email messages; Refer to Recognizing and Avoiding Email Scams (https://us-cert.cisa.gov/sites/default/files/publications/emailscams_0905.pdf) for more information on avoiding email scams; Refer to Avoiding Social Engineering and Phishing Attacks (https://us-cert.cisa.gov/ncas/tips/ST04-014) for more information on social engineering attacks.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-363107: An Improper Initialization Vulnerability Affects SIMATIC WinCC Kiosk Mode - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-363107.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-132-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-132-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-132-06 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-132-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" }, { "category": "external", "summary": "SSA-363107: An Improper Initialization Vulnerability Affects SIMATIC WinCC Kiosk Mode - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf" }, { "category": "external", "summary": "SSA-363107: An Improper Initialization Vulnerability Affects SIMATIC WinCC Kiosk Mode - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-363107.txt" } ], "title": "Siemens SIMATIC WinCC", "tracking": { "current_release_date": "2022-06-16T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-132-06", "initial_release_date": "2022-05-12T00:00:00.000000Z", "revision_history": [ { "date": "2022-05-12T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-22-132-06 Siemens SIMATIC WinCC" }, { "date": "2022-06-16T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-22-132-06 Siemens SIMATIC WinCC (Update A)" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC PCS 7 V9.0 and earlier", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SIMATIC PCS 7 V9.0 and earlier" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V9.1 SP1 UC01", "product": { "name": "SIMATIC PCS 7 V9.1", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SIMATIC PCS 7 V9.1" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC WinCC Runtime Professional V16 and earlier", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional V16 and earlier" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V17 Upd4", "product": { "name": "SIMATIC WinCC Runtime Professional V17", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional V17" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC WinCC V7.4 and earlier", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "SIMATIC WinCC V7.4 and earlier" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.5 SP2 Update 8", "product": { "name": "SIMATIC WinCC V7.5", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "SIMATIC WinCC V7.5" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-24287", "cwe": { "id": "CWE-1188", "name": "Initialization of a Resource with an Insecure Default" }, "notes": [ { "category": "summary", "text": "An authenticated attacker could escape the WinCC Kiosk Mode by opening the printer dialog in the affected application in case no printer is installed. CVE-2022-24287 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006" ] }, "references": [ { "summary": "CVE-2022-24287 - SIMATIC PCS 7 V9.1", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805072/" }, { "summary": "CVE-2022-24287 - SIMATIC WinCC Runtime Professional V17", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800913/" }, { "summary": "CVE-2022-24287 - SIMATIC WinCC V7.5", "url": "https://support.industry.siemens.com/cs/ww/en/view/109793460/" }, { "summary": "CVE-2022-24287 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-24287.json" }, { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2022-24287" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "Update to V9.1 SP1 UC01 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805072/" }, { "category": "mitigation", "details": "Update SIMATIC WinCC to V7.5 SP2 Update 8 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V17 Upd4 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800913/" }, { "category": "vendor_fix", "details": "Update to V7.5 SP2 Update 8 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109793460/" }, { "category": "mitigation", "details": "At least one default printer (but not a file based printer, as e.g. PDF/XPS printer) should be installed on the affected system", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006" ] }, { "category": "mitigation", "details": "No file based printer, as e.g. PDF/XPS printers, should be installed on the affected system", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006" ] }, { "category": "mitigation", "details": "Harden the application\u0027s host to prevent local access by untrusted personnel", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006" ] } ], "title": "CVE-2022-24287" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.