CERTFR-2014-AVI-126
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été corrigées dans le système SCADA Siemens SIMATIC. Elles permettent à un attaquant de provoquer un déni de service à distance et une injection de requêtes illégitimes par rebond (CSRF).
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
Siemens SIMATIC S7-1500 CPU
Impacted products
| Vendor | Product | Description |
|---|
References
| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [],
"affected_systems_content": "\u003cP\u003eSiemens SIMATIC S7-1500 CPU\u003c/P\u003e",
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2014-2248",
"url": "https://www.cve.org/CVERecord?id=CVE-2014-2248"
},
{
"name": "CVE-2014-2246",
"url": "https://www.cve.org/CVERecord?id=CVE-2014-2246"
},
{
"name": "CVE-2014-2251",
"url": "https://www.cve.org/CVERecord?id=CVE-2014-2251"
},
{
"name": "CVE-2014-2255",
"url": "https://www.cve.org/CVERecord?id=CVE-2014-2255"
},
{
"name": "CVE-2014-2257",
"url": "https://www.cve.org/CVERecord?id=CVE-2014-2257"
},
{
"name": "CVE-2014-2259",
"url": "https://www.cve.org/CVERecord?id=CVE-2014-2259"
},
{
"name": "CVE-2014-2253",
"url": "https://www.cve.org/CVERecord?id=CVE-2014-2253"
},
{
"name": "CVE-2014-2247",
"url": "https://www.cve.org/CVERecord?id=CVE-2014-2247"
},
{
"name": "CVE-2014-2249",
"url": "https://www.cve.org/CVERecord?id=CVE-2014-2249"
}
],
"links": [],
"reference": "CERTFR-2014-AVI-126",
"revisions": [
{
"description": "version initiale.",
"revision_date": "2014-03-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 corrig\u00e9es dans le syst\u00e8me SCADA\n\u003cspan class=\"textit\"\u003eSiemens SIMATIC\u003c/span\u003e. Elles permettent \u00e0 un\nattaquant de provoquer un d\u00e9ni de service \u00e0 distance et une injection de\nrequ\u00eates ill\u00e9gitimes par rebond (CSRF).\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans le syst\u00e8me SCADA Siemens SIMATIC",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-456423 du 12 mars 2014",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
}
]
}
CVE-2014-2249 (GCVE-0-2014-2249)
Vulnerability from cvelistv5 – Published: 2014-03-16 10:00 – Updated: 2024-08-06 10:05
VLAI?
EPSS
Summary
Cross-site request forgery (CSRF) vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 and SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:05:59.975Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-654382.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-079-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-654382.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-03-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-site request forgery (CSRF) vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 and SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-10T14:06:30",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-654382.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-079-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-654382.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-2249",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site request forgery (CSRF) vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 and SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-654382.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-654382.pdf"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-079-02",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-079-02"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-654382.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-654382.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2014-2249",
"datePublished": "2014-03-16T10:00:00",
"dateReserved": "2014-02-28T00:00:00",
"dateUpdated": "2024-08-06T10:05:59.975Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-2247 (GCVE-0-2014-2247)
Vulnerability from cvelistv5 – Published: 2014-03-16 10:00 – Updated: 2024-08-06 10:06
VLAI?
EPSS
Summary
The integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject headers via unspecified vectors.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:06:00.315Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-03-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject headers via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-10T14:06:23",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-2247",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject headers via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2014-2247",
"datePublished": "2014-03-16T10:00:00",
"dateReserved": "2014-02-28T00:00:00",
"dateUpdated": "2024-08-06T10:06:00.315Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-2248 (GCVE-0-2014-2248)
Vulnerability from cvelistv5 – Published: 2014-03-16 10:00 – Updated: 2024-08-06 10:06
VLAI?
EPSS
Summary
Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:06:00.210Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"name": "66190",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/66190"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-03-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-10T14:06:19",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"name": "66190",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/66190"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-2248",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"name": "66190",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/66190"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2014-2248",
"datePublished": "2014-03-16T10:00:00",
"dateReserved": "2014-02-28T00:00:00",
"dateUpdated": "2024-08-06T10:06:00.210Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-2246 (GCVE-0-2014-2246)
Vulnerability from cvelistv5 – Published: 2014-03-16 10:00 – Updated: 2024-08-06 10:06
VLAI?
EPSS
Summary
Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:06:00.220Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "66201",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/66201"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-03-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-10T14:06:20",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "66201",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/66201"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-2246",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "66201",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/66201"
},
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2014-2246",
"datePublished": "2014-03-16T10:00:00",
"dateReserved": "2014-02-28T00:00:00",
"dateUpdated": "2024-08-06T10:06:00.220Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-2257 (GCVE-0-2014-2257)
Vulnerability from cvelistv5 – Published: 2014-03-16 10:00 – Updated: 2024-08-06 10:06
VLAI?
EPSS
Summary
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted ISO-TSAP packets.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:06:00.259Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-03-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted ISO-TSAP packets."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-10T14:06:18",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-2257",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted ISO-TSAP packets."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2014-2257",
"datePublished": "2014-03-16T10:00:00",
"dateReserved": "2014-02-28T00:00:00",
"dateUpdated": "2024-08-06T10:06:00.259Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-2253 (GCVE-0-2014-2253)
Vulnerability from cvelistv5 – Published: 2014-03-16 10:00 – Updated: 2024-08-06 10:06
VLAI?
EPSS
Summary
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted Profinet packets.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:06:00.119Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-03-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted Profinet packets."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-10T14:06:22",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-2253",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted Profinet packets."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2014-2253",
"datePublished": "2014-03-16T10:00:00",
"dateReserved": "2014-02-28T00:00:00",
"dateUpdated": "2024-08-06T10:06:00.119Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-2255 (GCVE-0-2014-2255)
Vulnerability from cvelistv5 – Published: 2014-03-16 10:00 – Updated: 2024-08-06 10:05
VLAI?
EPSS
Summary
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTP packets.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:05:59.987Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-03-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTP packets."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-10T14:06:22",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-2255",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTP packets."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2014-2255",
"datePublished": "2014-03-16T10:00:00",
"dateReserved": "2014-02-28T00:00:00",
"dateUpdated": "2024-08-06T10:05:59.987Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-2259 (GCVE-0-2014-2259)
Vulnerability from cvelistv5 – Published: 2014-03-16 10:00 – Updated: 2024-08-06 10:06
VLAI?
EPSS
Summary
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTPS packets.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:06:00.300Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-03-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTPS packets."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-10T14:06:19",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-2259",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTPS packets."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2014-2259",
"datePublished": "2014-03-16T10:00:00",
"dateReserved": "2014-02-28T00:00:00",
"dateUpdated": "2024-08-06T10:06:00.300Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-2251 (GCVE-0-2014-2251)
Vulnerability from cvelistv5 – Published: 2014-03-16 10:00 – Updated: 2024-08-06 10:06
VLAI?
EPSS
Summary
The random-number generator on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:06:00.200Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-03-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The random-number generator on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-10T14:06:24",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-2251",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The random-number generator on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-456423.pdf"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2014-2251",
"datePublished": "2014-03-16T10:00:00",
"dateReserved": "2014-02-28T00:00:00",
"dateUpdated": "2024-08-06T10:06:00.200Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…