Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CNVD-2019-40512
Vulnerability from cnvd - Published: 2019-11-14
VLAI Severity ?
Title
Siemens Mentor Nucleus Networking Module存在未明漏洞
Description
Nucleus RTOS提供了一个高度可扩展的基于微内核的实时操作系统,设计用于跨越航空航天、工业和医疗应用范围的系统中的可扩展性和可靠性。
Siemens Mentor Nucleus Networking Module存在安全漏洞。攻击者可利用漏洞通过提供具体的订制DHCP包到Device,影响到该装置的Availability和完整性。
Severity
中
Patch Name
Siemens Mentor Nucleus Networking Module存在未明漏洞的补丁
Patch Description
Nucleus RTOS提供了一个高度可扩展的基于微内核的实时操作系统,设计用于跨越航空航天、工业和医疗应用范围的系统中的可扩展性和可靠性。
Siemens Mentor Nucleus Networking Module存在安全漏洞。攻击者可利用漏洞通过提供具体的订制DHCP包到Device,影响到该装置的Availability和完整性。目前,供应商发布了安全公告及相关补丁信息,修复了此漏洞。
Formal description
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf
Reference
https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf
Impacted products
| Name | ['Siemens VSTAR', 'Siemens Nucleus Source Code', 'Siemens Nucleus SafetyCert', 'Siemens Nucleus ReadyStart for ARM,MIPS,and PPC < V2017.02.2(Nucleus2017.02.02 Nucleus NET Patch)', 'Siemens Nucleus RTOS', 'Siemens Nucleus NET'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2019-13939"
}
},
"description": "Nucleus RTOS\u63d0\u4f9b\u4e86\u4e00\u4e2a\u9ad8\u5ea6\u53ef\u6269\u5c55\u7684\u57fa\u4e8e\u5fae\u5185\u6838\u7684\u5b9e\u65f6\u64cd\u4f5c\u7cfb\u7edf\uff0c\u8bbe\u8ba1\u7528\u4e8e\u8de8\u8d8a\u822a\u7a7a\u822a\u5929\u3001\u5de5\u4e1a\u548c\u533b\u7597\u5e94\u7528\u8303\u56f4\u7684\u7cfb\u7edf\u4e2d\u7684\u53ef\u6269\u5c55\u6027\u548c\u53ef\u9760\u6027\u3002\n\nSiemens Mentor Nucleus Networking Module\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u901a\u8fc7\u63d0\u4f9b\u5177\u4f53\u7684\u8ba2\u5236DHCP\u5305\u5230Device\uff0c\u5f71\u54cd\u5230\u8be5\u88c5\u7f6e\u7684Availability\u548c\u5b8c\u6574\u6027\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2019-40512",
"openTime": "2019-11-14",
"patchDescription": "Nucleus RTOS\u63d0\u4f9b\u4e86\u4e00\u4e2a\u9ad8\u5ea6\u53ef\u6269\u5c55\u7684\u57fa\u4e8e\u5fae\u5185\u6838\u7684\u5b9e\u65f6\u64cd\u4f5c\u7cfb\u7edf\uff0c\u8bbe\u8ba1\u7528\u4e8e\u8de8\u8d8a\u822a\u7a7a\u822a\u5929\u3001\u5de5\u4e1a\u548c\u533b\u7597\u5e94\u7528\u8303\u56f4\u7684\u7cfb\u7edf\u4e2d\u7684\u53ef\u6269\u5c55\u6027\u548c\u53ef\u9760\u6027\u3002\r\n\r\nSiemens Mentor Nucleus Networking Module\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u901a\u8fc7\u63d0\u4f9b\u5177\u4f53\u7684\u8ba2\u5236DHCP\u5305\u5230Device\uff0c\u5f71\u54cd\u5230\u8be5\u88c5\u7f6e\u7684Availability\u548c\u5b8c\u6574\u6027\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens Mentor Nucleus Networking Module\u5b58\u5728\u672a\u660e\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"Siemens VSTAR",
"Siemens Nucleus Source Code",
"Siemens Nucleus SafetyCert",
"Siemens Nucleus ReadyStart for ARM\uff0cMIPS\uff0cand PPC \u003c V2017.02.2\uff08Nucleus2017.02.02 Nucleus NET Patch\uff09",
"Siemens Nucleus RTOS",
"Siemens Nucleus NET"
]
},
"referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf",
"serverity": "\u4e2d",
"submitTime": "2019-11-13",
"title": "Siemens Mentor Nucleus Networking Module\u5b58\u5728\u672a\u660e\u6f0f\u6d1e"
}
CVE-2019-13939 (GCVE-0-2019-13939)
Vulnerability from cvelistv5 – Published: 2020-01-16 15:35 – Updated: 2025-06-10 15:17
VLAI?
EPSS
Summary
A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions < V2.8.2), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8.2 < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8.2 < V2.8.19), Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Desigo PXC00-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC00-U (All versions >= V2.3x and < V6.00.327), Desigo PXC001-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC100-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC12-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC128-U (All versions >= V2.3x and < V6.00.327), Desigo PXC200-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC22-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC22.1-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC36.1-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC50-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC64-U (All versions >= V2.3x and < V6.00.327), Desigo PXM20-E (All versions >= V2.3 < V6.0.327), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus Source Code (All versions), SIMOTICS CONNECT 400 (All versions < V0.3.0.330), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | |
|---|---|---|
|
|
||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | APOGEE MEC/MBC/PXC (P2) |
Affected:
All versions < V2.8.2
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T00:05:43.738Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-105-06"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-434032.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-162506.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "APOGEE MEC/MBC/PXC (P2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.8.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "APOGEE PXC Compact (BACnet)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.5.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "APOGEE PXC Compact (P2 Ethernet)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.8.19",
"status": "affected",
"version": "V2.8.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "APOGEE PXC Modular (BACnet)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.5.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "APOGEE PXC Modular (P2 Ethernet)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.8.19",
"status": "affected",
"version": "V2.8.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Capital Embedded AR Classic 431-422",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Capital Embedded AR Classic R20-11",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2303",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC00-E.D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.327",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC00-U",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.3x and \u003c V6.00.327"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC001-E.D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.327",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC100-E.D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.327",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC12-E.D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.327",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC128-U",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.3x and \u003c V6.00.327"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC200-E.D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.327",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC22-E.D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.327",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC22.1-E.D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.327",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC36.1-E.D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.327",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC50-E.D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.327",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXC64-U",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.3x and \u003c V6.00.327"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo PXM20-E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.327",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Nucleus NET",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Nucleus ReadyStart V3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2017.02.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Nucleus Source Code",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTICS CONNECT 400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V0.3.0.330"
}
]
},
{
"defaultStatus": "unknown",
"product": "TALON TC Compact (BACnet)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.5.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TALON TC Modular (BACnet)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.5.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions \u003c V2.8.2), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions \u003e= V2.8.2 \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions \u003e= V2.8.2 \u003c V2.8.19), Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), Desigo PXC00-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC00-U (All versions \u003e= V2.3x and \u003c V6.00.327), Desigo PXC001-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC100-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC12-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC128-U (All versions \u003e= V2.3x and \u003c V6.00.327), Desigo PXC200-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC22-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC22.1-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC36.1-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC50-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC64-U (All versions \u003e= V2.3x and \u003c V6.00.327), Desigo PXM20-E (All versions \u003e= V2.3 \u003c V6.0.327), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus Source Code (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.3.0.330), TALON TC Compact (BACnet) (All versions \u003c V3.5.3), TALON TC Modular (BACnet) (All versions \u003c V3.5.3). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T15:17:09.328Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-105-06"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-434032.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-162506.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-13939",
"datePublished": "2020-01-16T15:35:24",
"dateReserved": "2019-07-18T00:00:00",
"dateUpdated": "2025-06-10T15:17:09.328Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…