Action not permitted
Modal body text goes here.
Modal Title
Modal Body
Title
Siemens SIMATIC HMI Comfort Panels存在未明漏洞
Description
Siemens SIMATIC HMI Comfort Panels是德国西门子(Siemens)公司的一款触摸面板设备。
Siemens SIMATIC HMI Comfort Panels存在安全漏洞,该漏洞源于未正确限制通过控制面板访问Web浏览器,、未经身份验证的攻击者可利用该漏洞获得未授权访问,可能发现后门、执行未授权操作或利用配置错误导致进一步系统被攻破。
Severity
中
Patch Name
Siemens SIMATIC HMI Comfort Panels存在未明漏洞的补丁
Patch Description
Siemens SIMATIC HMI Comfort Panels是德国西门子(Siemens)公司的一款触摸面板设备。
Siemens SIMATIC HMI Comfort Panels存在安全漏洞,该漏洞源于未正确限制通过控制面板访问Web浏览器,、未经身份验证的攻击者可利用该漏洞获得未授权访问,可能发现后门、执行未授权操作或利用配置错误导致进一步系统被攻破。目前,供应商发布了安全公告及相关补丁信息,修复了此漏洞。
Formal description
厂商已发布了漏洞修复程序,请及时关注更新: https://cert-portal.siemens.com/productcert/html/ssa-387223.html
Reference
https://nvd.nist.gov/vuln/detail/CVE-2026-27662
Impacted products
| Name | ['Siemens SIMATIC HMI Unified Comfort Panels Hygienic family', 'Siemens SIMATIC HMI Unified Comfort Panels Standard family'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2026-27662",
"cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2026-27662"
}
},
"description": "Siemens SIMATIC HMI Comfort Panels\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u89e6\u6478\u9762\u677f\u8bbe\u5907\u3002\n\nSiemens SIMATIC HMI Comfort Panels\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u672a\u6b63\u786e\u9650\u5236\u901a\u8fc7\u63a7\u5236\u9762\u677f\u8bbf\u95eeWeb\u6d4f\u89c8\u5668\uff0c\u3001\u672a\u7ecf\u8eab\u4efd\u9a8c\u8bc1\u7684\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u83b7\u5f97\u672a\u6388\u6743\u8bbf\u95ee\uff0c\u53ef\u80fd\u53d1\u73b0\u540e\u95e8\u3001\u6267\u884c\u672a\u6388\u6743\u64cd\u4f5c\u6216\u5229\u7528\u914d\u7f6e\u9519\u8bef\u5bfc\u81f4\u8fdb\u4e00\u6b65\u7cfb\u7edf\u88ab\u653b\u7834\u3002",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://cert-portal.siemens.com/productcert/html/ssa-387223.html",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2026-23464",
"openTime": "2026-06-09",
"patchDescription": "Siemens SIMATIC HMI Comfort Panels\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u89e6\u6478\u9762\u677f\u8bbe\u5907\u3002\r\n\r\nSiemens SIMATIC HMI Comfort Panels\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u672a\u6b63\u786e\u9650\u5236\u901a\u8fc7\u63a7\u5236\u9762\u677f\u8bbf\u95eeWeb\u6d4f\u89c8\u5668\uff0c\u3001\u672a\u7ecf\u8eab\u4efd\u9a8c\u8bc1\u7684\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u83b7\u5f97\u672a\u6388\u6743\u8bbf\u95ee\uff0c\u53ef\u80fd\u53d1\u73b0\u540e\u95e8\u3001\u6267\u884c\u672a\u6388\u6743\u64cd\u4f5c\u6216\u5229\u7528\u914d\u7f6e\u9519\u8bef\u5bfc\u81f4\u8fdb\u4e00\u6b65\u7cfb\u7edf\u88ab\u653b\u7834\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens SIMATIC HMI Comfort Panels\u5b58\u5728\u672a\u660e\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"Siemens SIMATIC HMI Unified Comfort Panels Hygienic family",
"Siemens SIMATIC HMI Unified Comfort Panels Standard family"
]
},
"referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2026-27662",
"serverity": "\u4e2d",
"submitTime": "2026-05-20",
"title": "Siemens SIMATIC HMI Comfort Panels\u5b58\u5728\u672a\u660e\u6f0f\u6d1e"
}
CVE-2026-27662 (GCVE-0-2026-27662)
Vulnerability from cvelistv5 – Published: 2026-05-12 08:21 – Updated: 2026-05-13 01:48
VLAI
EPSS
Summary
Affected devices do not properly restrict access to the web browser via the Control Panel when no corresponding security mechanisms are in place.
This could allow an unauthenticated attacker to gain unauthorized access to the web browser, potentially enabling the discovery of backdoors, performing unauthorized actions, or exploiting misconfigurations that may lead to further system compromise.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-1188 - Initialization of a Resource with an Insecure Default
Assigner
References
1 reference
Impacted products
50 products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-27662",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-13T01:41:19.917677Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T01:48:49.217Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1000 Unified Comfort Panel",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1000 Unified Comfort Panel hygienic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1000, Unified Comfort Panel neutral",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extensio",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Unified Comfort Panel",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Unified Comfort Panel hygienic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Unified Comfort Panel hygienic neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Unified Comfort Panel neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Comfort Pro for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Comfort Pro for support arm (expandable, round tube) and extension unit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Comfort Pro for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Comfort Pro neutral design for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (expandable, round tube) and extensio",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Unified Comfort Panel",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Unified Comfort Panel hygienic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Unified Comfort Panel hygienic neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Unified Comfort Panel neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Comfort Pro for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Comfort Pro for support arm (expandable, round tube) and extension unit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Comfort Pro for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Comfort Pro neutral design for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (expandable, round tube) and extensio",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Unified Comfort Panel",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Unified Comfort Panel hygienic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Unified Comfort Panel hygienic neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Unified Comfort Panel neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Comfort Pro for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Comfort Pro for support arm (expandable, round tube) and extension unit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Comfort Pro for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Comfort Pro neutral design for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (expandable, round tube) and extensio",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Unified Comfort Hygienic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Unified Comfort Hygienic neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Unified Comfort Panel",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Unified Comfort Panel neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP700\u00a0Unified Comfort Panel",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP700, Unified Comfort Panel neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS HMI MTP1000 Unified Comfort",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS HMI MTP1200 Unified Comfort",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS HMI MTP700 Unified Comfort",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices do not properly restrict access to the web browser via the Control Panel when no corresponding security mechanisms are in place.\r\nThis could allow an unauthenticated attacker to gain unauthorized access to the web browser, potentially enabling the discovery of backdoors, performing unauthorized actions, or exploiting misconfigurations that may lead to further system compromise."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1188",
"description": "CWE-1188: Initialization of a Resource with an Insecure Default",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T08:21:13.221Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-387223.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-27662",
"datePublished": "2026-05-12T08:21:13.221Z",
"dateReserved": "2026-02-23T10:07:00.530Z",
"dateUpdated": "2026-05-13T01:48:49.217Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Loading…
Trend slope:
-
(linear fit over daily sighting counts)
Show additional events:
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…