CVE-2006-3999 (GCVE-0-2006-3999)
Vulnerability from cvelistv5 – Published: 2006-08-05 01:00 – Updated: 2024-08-07 18:48
VLAI?
Summary
ISS BlackICE PC Protection 3.6.cpj, 3.6.cpiE, and possibly earlier versions do not properly monitor the integrity of the pamversion.dll BlackICE library, which allows local users to subvert BlackICE by replacing pamversion.dll. NOTE: in most cases, the attack would not cross privilege boundaries because replacing pamversion.dll requires administrative privileges. However, this issue is a vulnerability because BlackICE is intended to protect against certain rogue privileged actions.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-07T18:48:39.409Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1016618",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://securitytracker.com/id?1016618"
},
{
"name": "20060801 ISS BlackICE PC Protection DLL faking of run-time linked libraries Vulnerability",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ",
"x_transferred"
],
"url": "http://www.securityfocus.com/archive/1/441829/100/0/threaded"
},
{
"name": "1338",
"tags": [
"third-party-advisory",
"x_refsource_SREASON",
"x_transferred"
],
"url": "http://securityreason.com/securityalert/1338"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2006-08-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "ISS BlackICE PC Protection 3.6.cpj, 3.6.cpiE, and possibly earlier versions do not properly monitor the integrity of the pamversion.dll BlackICE library, which allows local users to subvert BlackICE by replacing pamversion.dll. NOTE: in most cases, the attack would not cross privilege boundaries because replacing pamversion.dll requires administrative privileges. However, this issue is a vulnerability because BlackICE is intended to protect against certain rogue privileged actions."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-17T20:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "1016618",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://securitytracker.com/id?1016618"
},
{
"name": "20060801 ISS BlackICE PC Protection DLL faking of run-time linked libraries Vulnerability",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ"
],
"url": "http://www.securityfocus.com/archive/1/441829/100/0/threaded"
},
{
"name": "1338",
"tags": [
"third-party-advisory",
"x_refsource_SREASON"
],
"url": "http://securityreason.com/securityalert/1338"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2006-3999",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "ISS BlackICE PC Protection 3.6.cpj, 3.6.cpiE, and possibly earlier versions do not properly monitor the integrity of the pamversion.dll BlackICE library, which allows local users to subvert BlackICE by replacing pamversion.dll. NOTE: in most cases, the attack would not cross privilege boundaries because replacing pamversion.dll requires administrative privileges. However, this issue is a vulnerability because BlackICE is intended to protect against certain rogue privileged actions."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "1016618",
"refsource": "SECTRACK",
"url": "http://securitytracker.com/id?1016618"
},
{
"name": "20060801 ISS BlackICE PC Protection DLL faking of run-time linked libraries Vulnerability",
"refsource": "BUGTRAQ",
"url": "http://www.securityfocus.com/archive/1/441829/100/0/threaded"
},
{
"name": "1338",
"refsource": "SREASON",
"url": "http://securityreason.com/securityalert/1338"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2006-3999",
"datePublished": "2006-08-05T01:00:00",
"dateReserved": "2006-08-04T00:00:00",
"dateUpdated": "2024-08-07T18:48:39.409Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:iss:blackice_pc_protection:3.6cpie:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"57807099-784E-4CA8-BA6C-BC4BF15DEDC0\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:iss:blackice_pc_protection:3.6cpj:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0EA7FE32-A0F1-47DD-A306-E0369093083C\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"ISS BlackICE PC Protection 3.6.cpj, 3.6.cpiE, and possibly earlier versions do not properly monitor the integrity of the pamversion.dll BlackICE library, which allows local users to subvert BlackICE by replacing pamversion.dll. NOTE: in most cases, the attack would not cross privilege boundaries because replacing pamversion.dll requires administrative privileges. However, this issue is a vulnerability because BlackICE is intended to protect against certain rogue privileged actions.\"}, {\"lang\": \"es\", \"value\": \"ISS BlackICE PC Protection 3.6.cpj, 3.6.cpiE, y posiblemente anteriores versiones no monitorizan adecuadamente la integridad de la libreria pamversion.dll BlackICE, lo caul permite a un usuario local \\\"trastornar\\\" BlackICE a trav\\u00e9s del remplazo de pamversion.dll. NOTA: \\t\\r\\nen la mayor\\u00eda de los casos, el ataque no cruzar\\u00eda l\\u00edmites del privilegio porque substituir pamversion.dll requiere privilegios administrativos. Sin embargo, esta asunto es una vulnerabilidad porque BlackICE intenta proteger en contra de ciertas acciones \\\"ganujas\\\" privilegiadas.\"}]",
"id": "CVE-2006-3999",
"lastModified": "2024-11-21T00:14:54.377",
"metrics": "{\"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 4.6, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 3.9, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": true, \"userInteractionRequired\": false}]}",
"published": "2006-08-05T01:04:00.000",
"references": "[{\"url\": \"http://securityreason.com/securityalert/1338\", \"source\": \"cve@mitre.org\"}, {\"url\": \"http://securitytracker.com/id?1016618\", \"source\": \"cve@mitre.org\"}, {\"url\": \"http://www.securityfocus.com/archive/1/441829/100/0/threaded\", \"source\": \"cve@mitre.org\"}, {\"url\": \"http://securityreason.com/securityalert/1338\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"http://securitytracker.com/id?1016618\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"http://www.securityfocus.com/archive/1/441829/100/0/threaded\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-Other\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2006-3999\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2006-08-05T01:04:00.000\",\"lastModified\":\"2025-04-03T01:03:51.193\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"ISS BlackICE PC Protection 3.6.cpj, 3.6.cpiE, and possibly earlier versions do not properly monitor the integrity of the pamversion.dll BlackICE library, which allows local users to subvert BlackICE by replacing pamversion.dll. NOTE: in most cases, the attack would not cross privilege boundaries because replacing pamversion.dll requires administrative privileges. However, this issue is a vulnerability because BlackICE is intended to protect against certain rogue privileged actions.\"},{\"lang\":\"es\",\"value\":\"ISS BlackICE PC Protection 3.6.cpj, 3.6.cpiE, y posiblemente anteriores versiones no monitorizan adecuadamente la integridad de la libreria pamversion.dll BlackICE, lo caul permite a un usuario local \\\"trastornar\\\" BlackICE a trav\u00e9s del remplazo de pamversion.dll. NOTA: \\t\\r\\nen la mayor\u00eda de los casos, el ataque no cruzar\u00eda l\u00edmites del privilegio porque substituir pamversion.dll requiere privilegios administrativos. Sin embargo, esta asunto es una vulnerabilidad porque BlackICE intenta proteger en contra de ciertas acciones \\\"ganujas\\\" privilegiadas.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":true,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:iss:blackice_pc_protection:3.6cpie:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"57807099-784E-4CA8-BA6C-BC4BF15DEDC0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:iss:blackice_pc_protection:3.6cpj:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0EA7FE32-A0F1-47DD-A306-E0369093083C\"}]}]}],\"references\":[{\"url\":\"http://securityreason.com/securityalert/1338\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://securitytracker.com/id?1016618\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://www.securityfocus.com/archive/1/441829/100/0/threaded\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://securityreason.com/securityalert/1338\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://securitytracker.com/id?1016618\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.securityfocus.com/archive/1/441829/100/0/threaded\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…