CVE-2011-0342 (GCVE-0-2011-0342)
Vulnerability from cvelistv5 – Published: 2011-09-02 16:00 – Updated: 2024-08-06 21:51
VLAI?
Summary
Multiple buffer overflows in the InduSoft ISSymbol ActiveX control in ISSymbol.ocx 301.1104.601.0 in InduSoft Web Studio 7.0B2 hotfix 7.0.01.04 allow remote attackers to execute arbitrary code via a long parameter to the (1) Open, (2) Close, or (3) SetCurrentLanguage method.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T21:51:07.857Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "44875",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/44875"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://secunia.com/secunia_research/2011-61/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-11-273-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.indusoft.com/hotfixes/hotfixes.php"
},
{
"name": "49403",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/49403"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2011-09-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Multiple buffer overflows in the InduSoft ISSymbol ActiveX control in ISSymbol.ocx 301.1104.601.0 in InduSoft Web Studio 7.0B2 hotfix 7.0.01.04 allow remote attackers to execute arbitrary code via a long parameter to the (1) Open, (2) Close, or (3) SetCurrentLanguage method."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-05-21T09:00:00",
"orgId": "44d08088-2bea-4760-83a6-1e9be26b15ab",
"shortName": "flexera"
},
"references": [
{
"name": "44875",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/44875"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://secunia.com/secunia_research/2011-61/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-11-273-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.indusoft.com/hotfixes/hotfixes.php"
},
{
"name": "49403",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/49403"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "PSIRT-CNA@flexerasoftware.com",
"ID": "CVE-2011-0342",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple buffer overflows in the InduSoft ISSymbol ActiveX control in ISSymbol.ocx 301.1104.601.0 in InduSoft Web Studio 7.0B2 hotfix 7.0.01.04 allow remote attackers to execute arbitrary code via a long parameter to the (1) Open, (2) Close, or (3) SetCurrentLanguage method."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "44875",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/44875"
},
{
"name": "http://secunia.com/secunia_research/2011-61/",
"refsource": "MISC",
"url": "http://secunia.com/secunia_research/2011-61/"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-11-273-02",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-11-273-02"
},
{
"name": "http://www.indusoft.com/hotfixes/hotfixes.php",
"refsource": "CONFIRM",
"url": "http://www.indusoft.com/hotfixes/hotfixes.php"
},
{
"name": "49403",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/49403"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "44d08088-2bea-4760-83a6-1e9be26b15ab",
"assignerShortName": "flexera",
"cveId": "CVE-2011-0342",
"datePublished": "2011-09-02T16:00:00",
"dateReserved": "2011-01-06T00:00:00",
"dateUpdated": "2024-08-06T21:51:07.857Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:indusoft:web_studio:7.0b2:hotfix7.0.01.04:*:*:*:*:*:*\", \"matchCriteriaId\": \"6FB9C6B8-8C0B-4AD1-9F20-034F3A025C19\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Multiple buffer overflows in the InduSoft ISSymbol ActiveX control in ISSymbol.ocx 301.1104.601.0 in InduSoft Web Studio 7.0B2 hotfix 7.0.01.04 allow remote attackers to execute arbitrary code via a long parameter to the (1) Open, (2) Close, or (3) SetCurrentLanguage method.\"}, {\"lang\": \"es\", \"value\": \"M\\u00faltiples desbordamientos de buffer en el control ActiveX InduSoft ISSymbol en ISSymbol.ocx v301.1104.601.0 en InduSoft Web Studio v7.0B2 hotfix v7.0.01.04 permite a atacantes remotos ejecutar c\\u00f3digo de su elecci\\u00f3n a trav\\u00e9s de un par\\u00e1metro largo en el m\\u00e9todo (1) Open, (2) Close, o (3) SetCurrentLanguage.\"}]",
"id": "CVE-2011-0342",
"lastModified": "2024-11-21T01:23:46.477",
"metrics": "{\"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 10.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2011-09-02T16:55:01.460",
"references": "[{\"url\": \"http://ics-cert.us-cert.gov/advisories/ICSA-11-273-02\", \"source\": \"PSIRT-CNA@flexerasoftware.com\"}, {\"url\": \"http://secunia.com/advisories/44875\", \"source\": \"PSIRT-CNA@flexerasoftware.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://secunia.com/secunia_research/2011-61/\", \"source\": \"PSIRT-CNA@flexerasoftware.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://www.indusoft.com/hotfixes/hotfixes.php\", \"source\": \"PSIRT-CNA@flexerasoftware.com\"}, {\"url\": \"http://www.securityfocus.com/bid/49403\", \"source\": \"PSIRT-CNA@flexerasoftware.com\"}, {\"url\": \"http://ics-cert.us-cert.gov/advisories/ICSA-11-273-02\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"http://secunia.com/advisories/44875\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://secunia.com/secunia_research/2011-61/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://www.indusoft.com/hotfixes/hotfixes.php\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"http://www.securityfocus.com/bid/49403\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "PSIRT-CNA@flexerasoftware.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-119\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2011-0342\",\"sourceIdentifier\":\"PSIRT-CNA@flexerasoftware.com\",\"published\":\"2011-09-02T16:55:01.460\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Multiple buffer overflows in the InduSoft ISSymbol ActiveX control in ISSymbol.ocx 301.1104.601.0 in InduSoft Web Studio 7.0B2 hotfix 7.0.01.04 allow remote attackers to execute arbitrary code via a long parameter to the (1) Open, (2) Close, or (3) SetCurrentLanguage method.\"},{\"lang\":\"es\",\"value\":\"M\u00faltiples desbordamientos de buffer en el control ActiveX InduSoft ISSymbol en ISSymbol.ocx v301.1104.601.0 en InduSoft Web Studio v7.0B2 hotfix v7.0.01.04 permite a atacantes remotos ejecutar c\u00f3digo de su elecci\u00f3n a trav\u00e9s de un par\u00e1metro largo en el m\u00e9todo (1) Open, (2) Close, o (3) SetCurrentLanguage.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:indusoft:web_studio:7.0b2:hotfix7.0.01.04:*:*:*:*:*:*\",\"matchCriteriaId\":\"6FB9C6B8-8C0B-4AD1-9F20-034F3A025C19\"}]}]}],\"references\":[{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-11-273-02\",\"source\":\"PSIRT-CNA@flexerasoftware.com\"},{\"url\":\"http://secunia.com/advisories/44875\",\"source\":\"PSIRT-CNA@flexerasoftware.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://secunia.com/secunia_research/2011-61/\",\"source\":\"PSIRT-CNA@flexerasoftware.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.indusoft.com/hotfixes/hotfixes.php\",\"source\":\"PSIRT-CNA@flexerasoftware.com\"},{\"url\":\"http://www.securityfocus.com/bid/49403\",\"source\":\"PSIRT-CNA@flexerasoftware.com\"},{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-11-273-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://secunia.com/advisories/44875\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://secunia.com/secunia_research/2011-61/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.indusoft.com/hotfixes/hotfixes.php\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.securityfocus.com/bid/49403\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…